100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.2 TrustPilot
logo-home
Exam (elaborations)

Backflow Prevention Assembly 2025/26 Questions & Answers Graded A+

Rating
-
Sold
-
Pages
25
Grade
A+
Uploaded on
21-10-2025
Written in
2025/2026

Questions and Answers

Institution
Backflow Prevention Troubleshooting
Course
Backflow prevention troubleshooting










Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
Backflow prevention troubleshooting
Course
Backflow prevention troubleshooting

Document information

Uploaded on
October 21, 2025
Number of pages
25
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

Backflow Prevention Assembly 2025/26
Questions & Answers Graded A+

In responding to a backflow incident the water purveyor should


(A) Call the mayor
(B) Implement the emergency response plan
(C) Install a vacuum breaker
(D) Develop a good excuse
Implement the emergency response plan
A mixture of air and gas is considered hazardous when the mixture exceeds
what percentage of gthe lower explosive limit


(A) 0%
(B) 3%
(C) 7%
(D) 10%
10%
To exert a pressure of 1.0 psi at base of a water column the column would
have to be


(A) 4.34 high
(B) 14.7 high
(C) 27.75 high
(D) 33.89 high
27.75 high

,A DC must be tested


(A) Upon installation
(B) Every 6 month
(C) Annually on a health hazard
(D) none of the above
Upon installation
An absolute perssure of 25 psiaa (at sea level) is equal to approximately


(A) 5 psi
(B) 10 psi
(C) 20 psi
(D) 25 psi
10 psi
Dueing a field test the air inlet on PVB must open at


(A) Above 2.0 psid
(B) Below 1.0 psid
(C) Above 1.0 psid
(D) Below 2.0 psid
Above 1.0 psid
A differential pressuer gauge is used to field test


(A) PVB's
(B) Dual Checks
(C) AVB's
(D) All the above

, PVB's
Backflow in a water supply can be caused by


(A) Backpressure only
(B) A Barometric Loop
(C) Backsiphonage only
(D) Backpressure and Backsiphonage
Backpressure and Backsiphonage
A BPAT tester is required to report test information on the proper forms to
the


(A) Administrative authority
(B) Manufacturer's Rep
(C) EPA
(D) None of the above
Administrative authority
The relief valve opens when closing #2 shut off valve on a RP What is the most
probable cause


(A) #1 Shut off valve is open
(B) #2 Shut off valve is open
(C) #1 check is fouled open
(D) Shut off is leaking
#1 check is fouled open
When field testing the #1 Check of a RP the differential pressurw shouid be


(A) Greter than or equal to 5.0 psid
$8.19
Get access to the full document:

100% satisfaction guarantee
Immediately available after payment
Both online and in PDF
No strings attached

Get to know the seller
Seller avatar
StudyNestE

Get to know the seller

Seller avatar
StudyNestE Chamberlain College Of Nursng
View profile
Follow You need to be logged in order to follow users or courses
Sold
New on Stuvia
Member since
2 months
Number of followers
0
Documents
101
Last sold
-

0.0

0 reviews

5
0
4
0
3
0
2
0
1
0

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their exams and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can immediately select a different document that better matches what you need.

Pay how you prefer, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card or EFT and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions