ACTUAL QUESTIONS AND CORRECT
ANSWERS
Which of the following types of discontinuities cannot be detected by liquid penetrant test
method
A. Surface laminations
B. Internal forging bursts
C. Surface cracks
D. Surface laps - CORRECT ANSWER B. Internal forging bursts
Which of the following discontinuities would be impossible to detect using liquid penetrant
test?
A. A forging lap
B. A crater crack
C. Grinding crack
D. Non-metallic internal inclusions - CORRECT ANSWER D. Non-metallic internal
inclusions
Which of the statements below applies to the liquid penetrant method of testing
A. The penetrant test method is less flexible than the eddy current test method
B. The penetrant test method is less reliable than the magnetic particle method for finding
surface defects
C. The penetrant test method will not detect fatigue cracks
D. The penetrant test method is more reliable than radiograph testing when attempted to
detect minute surface cracks. - CORRECT ANSWER D. The penetrant test method is
more reliable than radiograph testing when attempted to detect minute surface cracks.
,Prior to the penetrant testing of a previously machine, soft metal part, which of the cleaning
methods listed below would best remove any smeared metal that could mask discontinuities
A. Etching
B. Shot peening
C. Alkaline cleaning
D. Water cleaning with detergent. - CORRECT ANSWER A. Etching
Which of the following statements below best states the danger of using sandblasting for
cleaning surfaces to be penetrant tested
A. The discontinuities may be closed.
B. Oil contaminants might be sealed in the discontinuities.
C. The sand used in the sandblasting operation may be forced into the discontinuity.
D. The sandblasting operation may introduced discontinuities in the part. - CORRECT
ANSWER A. The discontinuities may be closed.
Penetrant residues may become entrapped under spine, fastener, rivet, etc. Which of the
following is most likely reaction caused by such residue
A corrosion caused by the moisture attached by such residues
B paint stripping
C Fatigue, cracking
D latest structure breakdown - CORRECT ANSWER A
Which material should be avoided in penetrant system, when testing titanium alloys
A. Carbon or oil
B. Halogenated solvents
C. Emulsifier or oil
, D. Fluorescent agents. - CORRECT ANSWER B
Which of the following contaminants could affect sensitivity of a penetrant
A. Acid
B. Water.
C. Salt.
D. All of the above. - CORRECT ANSWER D
Which of the following statements concerning contaminating materials on a surface of a
penetrant test specimen is false
A. The contaminant may be of Composition that attacks the penitent, and reduces the
fluorescent or color of penetrate
B. Contaminant reduce or even prevent capillary action by the penetrant
C. The contaminant may retain the penetrant, and thus increase the sensitivity of the
inspection.
D. The contaminate may completely fill the crack dust prevent the entry of penetrant. -
CORRECT ANSWER C
Aluminum alloy test specimens that have been tested by liquid penetrant method should be
thoroughly cleaned after testing because
A. The acid in the penetrant may cause severe corrosion.
B. The alkaline content of developer and moist emulsifier could result in surface pitting,
particularly in moist atmospheres
C. The toxic residue from the test will severely inhabit the application of paint on aluminum
alloys.
D. - CORRECT ANSWER B