• Wrong document? Swap it for free
  • Written by students who passed
  • Immediately available after payment
  • Read online or as PDF
Sell
Where do you study
Your language
Document preview thumbnail
Preview 3 out of 19 pages
Exam (elaborations)

NATE Heat Pump Test Guide 100% Verified Questions & Answers | Grade A | Latest 2026/2027

Document preview thumbnail
Preview 3 out of 19 pages

1. What can cause a lower than normal suction pressure: A restricted drier 2. What is a primary consideration when bending soft copper tubing into a bend of any radius?: The cross-sectional are of the tube must not be significantly reduced 3. When is vapor line condensation of a residential heat pump in the cooling mode a concern?: Routing refrigerant line within a wall 4. Bent vanes on a direct drive blower wheel in an air handler can cause:: Loss in airflow, excessive blower motor wear, and increased noise 5. A technician measures the return air temperature of a 100,000 Btu output furnace to be 65 F and the supply side air temperature is 135 F. What is the SCFM (standard CFM)?: 1323 SCFM NATE Heat 1 / 19 6. What would cause a voltage reading across a closed contact in a 24V control circuit?: Pitted or dirty contacts 7. A reason for cool air complaints when a heat pump is operating in the heating cycle is:: Excessive supply air velocitie

Content preview

1
NATE Heat




NATE Heat Pump Test Guide 100%
Verified Questions & Answers | Grade A |
Latest 2026/2027



1. What can cause a lower than normal suction pressure: A restricted drier

2. What is a primary consideration when bending soft copper tubing into a

bend of any radius?: The cross-sectional are of the tube must not be

significantly reduced

3. When is vapor line condensation of a residential heat pump in the cooling

mode a concern?: Routing refrigerant line within a wall

4. Bent vanes on a direct drive blower wheel in an air handler can cause:: Loss

in airflow, excessive blower motor wear, and increased noise

5. A technician measures the return air temperature of a 100,000 Btu output

furnace to be 65 F and the supply side air temperature is 135 F. What is the

SCFM (standard CFM)?: 1323 SCFM



NATE Heat

,6. What would cause a voltage reading across a closed contact in a 24V control

circuit?: Pitted or dirty contacts

7. A reason for cool air complaints when a heat pump is operating in the

heating cycle is:: Excessive supply air velocitie

8. The purpose of performing a duct traverse is to determine the average

duct:: Airflow using multiple CFM readings taken from several locations

across the cross section of the duct. 17 When fabricating ductboard for a

horizontal duct 36" X 24", which of the following is a preferred method for

preventing wall deflection?: Use 12 gauge rods, both horizontally and

vertically at a minimum of every 16"

18. What is used to measure duct static pressure?: Differential pressure

gauge

19. To more accurately sense the refrigerant temperature of horizontal

suction line that are 1 1⁄2 or lager, a thermostatic expansion valve sensing

bulb should be mounted at which positions?: 4 or 8 o'clock

20. What are the first two checks typically made on an electronic control?:

Presence of proper input signals and proper output voltages




, 21. The technician suspects that an outdoor thermostat used to bring on

auxiliary heat may be out of calibration. The thermostat is a close-on-fall

type that is adjustable. One method for checking the thermostats

calibration is to:: Manually

rotate the shaft until the thermostat closes and compare the dial setting to an

accurate outdoor temperature reading plus 10 F

22. In an economizer system, when the outdoor air enthalpy exceeds

setpoint, the outdoor air enthalpy exceeds setpoint, the outdoor air

damper: Closes to a preset minimum position

23. What effect does a low charge have on the switchover operation of a

reversing valve?: Reversing valves are less likely to shift if charges is very low

24. What is an effective method for reducing the transmissions from an air

handler installed in a closet?: Place the cabinet on an isolation pad

25. A technician finds a compressor contactor energized, but the compressor

is not running. To troubleshoot, the technician should check for proper.:

Voltage to the load

Document information

Uploaded on
October 11, 2025
Number of pages
19
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$11.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
DoctorKen
3.8
(169)
Sold
934
Followers
122
Items
6648
Last sold
9 hours ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their exams and reviewed by others who've used these revision notes.

Didn't get what you expected? Choose another document

No problem! You can straightaway pick a different document that better suits what you're after.

Pay as you like, start learning straight away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and smashed it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions