100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.2 TrustPilot
logo-home
Exam (elaborations)

3rd Class Stationary Steam Engineer License Exam Prep 2025/2026 | Study Guide with Practice Questions & Answers

Rating
-
Sold
-
Pages
16
Grade
A+
Uploaded on
20-09-2025
Written in
2025/2026

Get fully prepared for your 3rd Class Stationary Steam Engineer License Exam with this latest 2025/2026 updated prep guide. This study resource includes: ️ Comprehensive exam review material ️ Practice questions with correct answers ️ Covers steam systems, safety, boiler operations, combustion, pumps, valves, and controls ️ Based on official stationary engineer exam requirements ️ Easy-to-follow explanations designed to boost understanding ️ Updated for 2025/2026 testing standards Perfect for apprentices, operators, and engineers aiming to pass the 3rd Class Stationary Steam Engineer License Exam with confidence.

Show more Read less
Institution
3rd Class Stationary Steam Engineer License
Course
3rd Class Stationary Steam Engineer License










Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
3rd Class Stationary Steam Engineer License
Course
3rd Class Stationary Steam Engineer License

Document information

Uploaded on
September 20, 2025
Number of pages
16
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

3rd Class Stationary Steam Engineer License Exam Prep
2025/2026 | Study Guide with Practice Questions & Answers



time, temperature, mixture, and atomization correct answers _________ are necessary
for complete combustion

214.7 correct answers if the steam pressure gauge indicates 200 PSIG, the absolute
pressure is______

12 correct answers a boiler is operating at 400 PSI, and the safety valve opens at 410
PSI and closes at 398 PSI. The blowdown is______psi

steam turbine correct answers an oil cooler is commonly used with a(n) ________ when
operating in conjunction with a turbo-generator

superheated correct answers a boiler is producing 40,000lb of steam/hr at a pressure of
100 PSI and a steam temperature of 500 degrees Fahrenheit. The steam produced is
_______ steam

add heat to the feed water correct answers the economizer on a boiler is used to
_______

water tube correct answers blowers are normally used with________ boilers

scale on tubes correct answers overheating of tubes on a boiler can be caused
by________

channeling correct answers carbon dioxide in a condensate return system
causes_________

reciprocating correct answers a ________ pump is a positive displacement pump

6,000,000 correct answers a boiler generating 6000 lb of steam/hr produces
_______btu/hr

discharge sludge and sediment correct answers a bottom blowdown is performed on a
boiler to _____

1 correct answers water columns are connected to the boiler with a minimum of
_______" pipe

,3/4 correct answers the minimum size of a water column blowdown valve is_______".

2 1/2 correct answers the maximum size bottom blowdown valve on a boiler
is_________".

a steam trap correct answers a ________ allows condensate to pass through, but stops
Steam.

water level in each boiler correct answers when taking over a shift, the first thing to do is
check the________

two or more safety valves correct answers according to the asme code, a high-pressure
boiler having more than 500 square feet of heating surface shall have________

dirty heating services correct answers the probable cause of an increase in temperature
of gases of combustion at the boiler Outlet is____

manhole openings correct answers boilers in battery equipped with________ must have
two main steam stop valves and a free-flowing drain between them

blowdown the gauge glass correct answers in order to be sure the gauge glass is
indicating an accurate water level reading, the stationary engineer should______

in the Steam and water drum well below the nowl correct answers a continuous
blowdown line is located___

176 correct answers a temperature reading of 80 degrees Celsius is equal
to_________°f

poor efficiency correct answers a chimney temperature of 250 degrees Fahrenheit
above steam temperature indicates_______

inches of water correct answers a manometer is red in________

be raised correct answers the boiling point of water will____ with an increase in
pressure

hard correct answers if a lather is not obtained when performing a soap hardness test,
the water sample is_______

preheated correct answers combustion efficiency can be increased when air
is________

induced correct answers ______ draft is produced by a fan located between the boiler
and the chimney

, before putting the steam turbine on-line correct answers the overspeed trip on a steam
turbine should be tested ______

High combustion efficiency correct answers a high CO2 reading in the gases of
combustion is a sign of____

turn scale-forming salts to a non adhering sludge correct answers the purpose of
chemically treating feedwater is to________

Loop seal or internal overflow correct answers water in a d rating feed water heater is
prevented from entering the steam line by a(n) _______.

3960 correct answers a steam turbine operating at 3600 RPM will trip at_________ rpm

steam drum correct answers he steam line going to The Blowers is connected to the
main ________

drain set blower lines correct answers before using blowers on a boiler,________

decreases boiler efficiency correct answers an accumulation of snow on the Fireside of
a boiler tubes________

under correct answers a globe valve installed in the feed water line between the feed
water pump and boiler has a pressure from the feed water pump_________ the valve
disc

1 1/2 correct answers the range of a pressure gauge should be twice the safety valve
setting, but not less than______ time (s) the safety valve setting

air- or water-driven turbines correct answers hard scale formed on the inside of tubes is
best removed by________

secure fires correct answers to correct a low water condition,_____

establish steam flow correct answers desuperheater drain is used to_______

there is a broken baffle correct answers a sudden rise in chimney temperature with no
increase in load indicates______

100,000 btu/therm correct answers the btu content of natural gas is_____

higher than correct answers the safety valve setting on the Steam and water drum is
________ a superheater safety valve

18750 BTU / lb correct answers the btu content of number 6 fuel oil is approximately

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Successscore University Of Phoenix
View profile
Follow You need to be logged in order to follow users or courses
Sold
22
Member since
2 months
Number of followers
0
Documents
1251
Last sold
1 week ago
Ultimate Study Resource | Nursing, HESI, ATI, TEAS, Business & More

Welcome to your one-stop exam prep store!

3.0

3 reviews

5
0
4
2
3
0
2
0
1
1

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their exams and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can immediately select a different document that better matches what you need.

Pay how you prefer, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card or EFT and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions