Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Document preview thumbnail
Preview 4 out of 60 pages
Exam (elaborations)

EEG Board Exam 2025/2026 – Actual Exam Questions with Verified Correct Answers | Fully Updated Study Guide

Document preview thumbnail
Preview 4 out of 60 pages

This study guide provides the latest EEG Board Exam questions for the 2025/2026 cycle, complete with verified correct answers. It is fully updated to reflect the current exam format and requirements, ensuring accurate and reliable preparation. With real exam-style content, this resource is ideal for focused practice and boosting confidence before the test.

Content preview

1



EEG Board Exam 2025/2026 – Actual
Exam Questions with Verified Correct
Answers | Fully Updated Study Guide
Section 1: EEG Technical Sciences and Electrode Placement
Question 1

What is the primary physiological signal measured by an EEG?
A. Glucose metabolism rates
B. Electrical activity from cortical neurons
C. Magnetic fields produced by ion channels
D. Hemoglobin oxygenation changes

Correct Answer: B. Electrical activity from cortical neurons
Rationale: EEG records the summed electrical potentials generated by cortical neurons,
primarily pyramidal cells, through scalp electrodes. It does not measure magnetic fields (MEG),
blood oxygenation (fMRI), or glucose metabolism (PET).



Question 2

Which electrode placement system is most commonly used in clinical EEG?
A. 10–20 system
B. 12-lead system
C. International 94 system
D. 5–10 system

Correct Answer: A. 10–20 system
Rationale: The International 10–20 system is the standard for clinical EEG electrode
placement, ensuring reproducibility across recordings. The 12-lead system is used for ECG, and
the 5–10 system is a high-density variant less common in clinical practice.



Question 3

What is the normal frequency range of the alpha rhythm in adults?
A. 4–7 Hz

Page 1 of 60

, 2


B. 8–13 Hz
C. 14–30 Hz
D. 0.5–4 Hz

Correct Answer: B. 8–13 Hz
Rationale: The alpha rhythm, prominent in awake, relaxed adults with eyes closed, typically
falls between 8–13 Hz over occipital regions. Theta (4–7 Hz) and delta (0.5–4 Hz) are slower,
and beta (14–30 Hz) is faster.



Question 4

What is the minimum sampling rate required to accurately record a 70 Hz EEG signal, per the
Nyquist Theory?
A. 70 Hz
B. 100 Hz
C. 140 Hz
D. 200 Hz

Correct Answer: C. 140 Hz
Rationale: The Nyquist Theory states that the sampling rate must be at least twice the
highest frequency recorded. For a 70 Hz signal, the minimum sampling rate is 140 Hz to avoid
aliasing.



Question 5

Where should collodion and acetone be stored in an EEG lab?
A. Open shelf
B. Flammable cabinet
C. Refrigerator
D. General storage room

Correct Answer: B. Flammable cabinet
Rationale: Collodion and acetone are flammable substances requiring storage in a
designated flammable cabinet to meet OSHA safety standards.



Question 6

What are the two active ingredients in collodion used for EEG electrode application?
A. Ethanol and water

Page 2 of 60

, 3


B. Ethyl ether and ethanol
C. Acetone and saline
D. Glycerin and alcohol

Correct Answer: B. Ethyl ether and ethanol
Rationale: Collodion contains ethyl ether and ethanol, which provide adhesive properties for
securing EEG electrodes.



Question 7

What is the purpose of calibration in EEG recording?
A. To increase signal amplitude
B. To detect instrument faults and verify channel integrity
C. To reduce patient discomfort
D. To adjust electrode placement

Correct Answer: B. To detect instrument faults and verify channel integrity
Rationale: Calibration ensures EEG equipment functions correctly by comparing known
potentials and verifying that all channels amplify and filter uniformly.



Question 8

What causes over-dampening in an EEG recording, resulting in rounded waveforms?
A. High pen pressure
B. Low pen pressure
C. Incorrect filter settings
D. Faulty electrodes

Correct Answer: A. High pen pressure
Rationale: Over-dampening, caused by high pen pressure, slows the pen and produces
rounded waveforms, affecting signal clarity.



Question 9

What is the bit number for optimal resolution display in EEG systems?
A. 8 bits
B. 10 bits
C. 11 bits, preferably 12
D. 16 bits

Page 3 of 60

, 4


Correct Answer: C. 11 bits, preferably 12
Rationale: A resolution of 11–12 bits ensures sufficient detail for EEG signal display,
balancing data accuracy and storage requirements.



Question 10

Which filter settings create a very narrow band pass and should rarely be used clinically?
A. LF 1.0 Hz and HF 70 Hz
B. LF 5.0 Hz and HF 15 Hz
C. LF 0.5 Hz and HF 100 Hz
D. LF 2.0 Hz and HF 50 Hz

Correct Answer: B. LF 5.0 Hz and HF 15 Hz
Rationale: A low-frequency filter of 5.0 Hz and high-frequency filter of 15 Hz create a
narrow band pass, potentially missing critical EEG activity, and are rarely used clinically.




Section 2: EEG Patterns and Interpretation
Question 11

What activation procedure is useful for detecting absence seizures?
A. Photic stimulation
B. Hyperventilation
C. Sleep deprivation
D. Auditory stimulation

Correct Answer: B. Hyperventilation
Rationale: Hyperventilation can provoke absence seizures, characterized by 3 Hz spike-and-
wave discharges, making it a standard activation procedure.



Question 12

What activation is effective for detecting benign rolandic epilepsy?
A. Hyperventilation
B. Photic stimulation
C. Sleep activation
D. Tactile stimulation



Page 4 of 60

Document information

Uploaded on
September 12, 2025
Number of pages
60
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$14.50

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
STUVIAACTUALEXAMS
3.5
(161)
Sold
1250
Followers
208
Items
9036
Last sold
23 hours ago

Reviews from verified buyers




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions