100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4,6 TrustPilot
logo-home
Examen

IICRC Applied Structural Drying | Complete Study Guide with Questions and Answers

Puntuación
-
Vendido
-
Páginas
13
Grado
A+
Subido en
10-09-2025
Escrito en
2025/2026

This document provides a comprehensive study guide for IICRC Applied Structural Drying (ASD), including detailed questions, answers, and calculation examples. Topics covered include air movers, dehumidifiers, air filtration devices, drying standards, psychrometrics, moisture measurement, water loss categories and classes, and safety regulations. It serves as a full preparation resource for restoration professionals studying for certification or reviewing field practices.

Mostrar más Leer menos
Institución
IICRC
Grado
IICRC









Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
IICRC
Grado
IICRC

Información del documento

Subido en
10 de septiembre de 2025
Número de páginas
13
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

IICRC - Applied Structural Drying

1 AFD - ANS Structure dimensions are 30' x40' x8'
According to the IICRC the desired air change rate per hour (ACR) is 4. The AFDs
you have are rated at 700 CFM.
How many AFDs will you need.
Calculation: Cubic Feet (CF) x ACH / 60 = CFM
CFM/Rated CFM= # of AFD

1. Tightness of the building envelope
2. Prevailing weather
3. HVAC
4. Class of Water
5. Building Construction
5. Build out density - ANS Favors that affect the detailed dehumidifier
calculation is:

15
20 - ANS Residential v. commercial - generally, residential ______amp /
commercial ______ amp
(consider never using over 80% of available amperage)

2 desiccants - ANS You are working on a class 3 water loss that has an
affected area of 15120 CF. You plan to dry the area with a desiccant dehu AHAM
rated at 385 CFM. How many of these dehumidifiers do you need to install on this
project

2 LGR dehumidifiers - ANS A water supply line broke in a home affecting the
kitchen, dining room and family room. This is a class 3 Loss
Total sq ft is 1170 with 8' ceilings.
Using the information above and the simplified calculation (per IICRC), how many
125 ppd LGR dehumidifiers would recommended as an initial deployment to start
drying the affected structure.

2 LGR dehumidifiers - ANS You are working on a class 2 water loss that has
two affected areas. Area 1 is 3750CF and Area 2 is 2700CF
You plan to dry both areas together using an LGR Dehu rated at 80 ppd at AHAM.
How many of these dehus do you need to install on this project.

20%
16% - ANS _____% rotting fungi growth IN wood
_____% - non-rotting fungi growth ON wood

, IICRC - Applied Structural Drying

3 AFDs - ANS Structure dimensions are 45' x 50' x 10'. Calculate using 4ACH.
The AFDs you have are rated at 500 CFM.
How many AFDs would you need for this project?

Calculation: Cubic Feet (CF) x ACH / 60 = CFM
CFM/Rated CFM= # of AFD

3-4 air movers - ANS The dining room is 115sq ft. 8' high ceilings with little to
no wicking. Floor is the only area wet. What is the range of air movers you would
place?

3. Hallway : 70oz nylon, direct glue installation - ANS Which wet carpet floor
covering would be the easiest to extract (Cat 1 | Class 1)
1. Dining Room: 50oz loop-pile nylon with #8 bonded urethane cushion
2. Living Room: 32oz cut-pile polypropylene with #6 bonded urethane cushion
3. Hallway : 70oz nylon, direct glue installation

45360 CFH - ANS You are working on a class 3 water loss that has an
affected area of 15120 CF. You plan to dry the area with a desiccant dehu. What is
the CFH?

5-6 air movers - ANS A room that is 235 sq ft. 8' high ceilings with little to no
wicking. Floor is the only area wet. What is the range of air movers you would place?

6-7 air movers - ANS A room is 186 sqft (8' ceilings) with one offset larger than
18" (included in the sq ft calculation).
The entire floor area is wet and walls show only minor wicking except for Wall A and
B - totaling 90 sqft
The ceiling is not affected.
What is the range of air movers you would need for this using the IICRC calculation
guide

7- ANS If using LGRs, the water category is 3 and the cubic feet of the area is
280. What is the minimum initial dehumidifier AHAM rated performance pint capacity
recommendation. (using the IICRC Initial Dehumidification Recommendation
Calculation Sheet)

7.48 - ANS Gallons per cubic foot of water depth

70°F - 90°F - ANS Ideal temperature for a Refrigerant of LGR dehumidifier

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
FLYINGHIGHER Chamberlain College Of Nursing
Ver perfil
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
6255
Miembro desde
5 año
Número de seguidores
5531
Documentos
5338
Última venta
1 día hace
DENIM

BEST HOMEWORK HELP AND TUTORING ,ALL KIND OF QUIZ or EXAM WITH GUARANTEE OF A Am an expert on major courses especially; psychology,Nursing, Human resource Management.Assisting students with quality work is my first priority. I ensure scholarly standards in my documents and that's why i'm one of the BEST GOLD RATED TUTORS in STUVIA. I assure a GOOD GRADE if you will use my work.

4.1

1259 reseñas

5
718
4
204
3
188
2
52
1
97

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes