fire department connection - (ANSWER)normally on exterior of building... FDNY
can pump supplemental water into the sprinkler system, standpipe, or other
system furnishing water for fire extinguishment to supplement existing water
supplies.



system control valve - (ANSWER)valve controlling flow to water-based fire
protection systems.



fire command center - (ANSWER)Designated room or area in a structure where
the status of the fire detection, alarm, and protection systems is displayed and
the systems can be manually controlled.



Fire pump, automatic standpipe. - (ANSWER)A fire pump located at or below
street level that supplies the lower 300 feet (91.4 m) of a standpipe system or a
combined standpipe and sprinkler system.



tags - (ANSWER)on closed section valves serving affected areas: area affected,
brief description, occupancy classification, c of f number, estimated time until
operational



Green tag - (ANSWER)no impairment found in entire system- main control valve

, 2


red tag - (ANSWER)place on main control valve if FULLY out of service... put
sprinkler company name, date of removal from service and anticipated time to
operational



blue disk - (ANSWER)partially out of service- on all fire department connections



water storage tank - (ANSWER)Collects cooled water



OS & Y valve - (ANSWER)indicating type of control valve used for fire sprinkler
system



deluge valve - (ANSWER)water supply control valve intended to be operated by
actuation of an automatic detection system that is installed in the same area as
the discharge devices. INTENDED USE IS MANUAL AND AUTO



deluge sprinkler system - (ANSWER)employing open sprinklers that are attached
to a piping system that is connected to a water supply through a valve that is
opened by the operation of a detection system installed in the same areas as the
sprinklers. WHEN IT OPENS, water flows into the piping system and discharges
from all sprinklers attached.



Early suppresion fast response sprinklers - (ANSWER)fast response sprinkler that
is listed for its capability to provide fire suppression of specific high challenge fire
hazards

, 3


extra large orifice sprinklers - (ANSWER)= or > 1 inch less pressure to achieve a
given discharge density



extended coverage sprinkler - (ANSWER)400 max square feet discharge 20 foot
by 20 foot spacing between sprinklers



fire pump - (ANSWER)a provider of liquid flow and pressure dedicated to fire
protection. A fire pump is a part of a fire sprinklers system water supply and can
be powered by electric, diesel or steam. connected to public water source or tank.
provides higher pressure to sprinkler system



Glass bulb sprinkler - (ANSWER)operated by heat breaking a glass bulb filled with
a non freezing liquid with diameters that vary form 3 mm for quick response to 5
mm for standard response



hose valve - (ANSWER)valve to additional hose connection



hydraulic placard - (ANSWER)sign attached to a hydraulically calculated sprinkler
system indicating the design density, required gallons per minute and pressure for
the system to operate properly



hydraulically calculated systems - (ANSWER)method of sizing auto sprinkler
piping using a prescribed amount of water to be distributed over a specific area.

, 4


impairment coordinator - (ANSWER)in charge of safety during out of service
systems



intermediate level sprinkler - (ANSWER)sprinkler equipped with integral shields
to protect the operating elemtn form discharge from sprinklers installed at higher
elevations



large orifice sprinkler - (ANSWER)sprinkler head with orifice size equal or greater
than 3/4 and less than 1 inch



listed device - (ANSWER)A fire protection component that has been tested to
perform under parameters specified for its use by a nationally recognized testing
agency. Underwriter's Laboratory (UL) and Factory Mutual (FM) are the two most
common.



Master Pressure Reducing Valve - (ANSWER)A pressure reducing valve installed
to regulate pressures in an entire fire protection system and/or standpipe system
zone.



Main Drain - (ANSWER)The primary drain connection located on the system riser
and also utilized as a flow test connection.



Microbiologically Influenced Corrosion (MIC) - (ANSWER)Corrosion caused by the
presence of microbes in the water supply that over time attack the interior of
metallic piping and cause leaks, pitting, and blockages.

Document information

Uploaded on
September 9, 2025
Number of pages
57
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$23.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
TheAlphanurse
4.2
(384)
Sold
5790
Followers
179
Items
6641
Last sold
3 days ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions