The continued use of an existing connection of a solid fuel burning appliance to a chimney flue to which another appliance burning oil or solid fuel is connected for any chimney existing and in use before feb 2, 1998 shall be permitted assuming... - ANSWERSSufficent draft for each appliance, the chimney is lined and structuraly intact, a carbon monoxide detector is installed near a bedroom The connection of a solid fuel burning appliance to a chimney flue to which another appliance burning oil or solid fuel is connected for any chimney existing and in use on or after February 2, 1998 shall be permitted as long as... - ANSWERSSufficient draft is available for each appliance, the chimney is lined and structurally intact, a carbon monoxide detector installed near a bedroom, the solid fuel appliance has been listed by an independent nationally recognized testing lab approved by the board, the solid fuel burning appliance is installed in accordance with manufacturers specs. Fuel oil licenses expire... - ANSWERSEvery 2 years If the owner, occupant of any building or an installer neglects or refuses without justification for more than ____ days to comply with any order of a state fuel inspector, the person commits a civil violation for a fine of $100 each day neglected - ANSWERS10 A person ordered by a state fuel inspector to correct a deficiency or to vacate a building or structure may appeal the order by filling a written notice of appeal with the board within ____ days after receipt of the order - ANSWERS30 A

Content preview

MASTER OIL EXAM QUESTIONS AND
ANSWERS 2025

,The continued use of an existing connection of a solid fuel burning appliance to a
chimney flue to which another appliance burning oil or solid fuel is connected for any
chimney existing and in use before feb 2, 1998 shall be permitted assuming... -
ANSWERSSufficent draft for each appliance, the chimney is lined and structuraly intact,
a carbon monoxide detector is installed near a bedroom

The connection of a solid fuel burning appliance to a chimney flue to which another
appliance burning oil or solid fuel is connected for any chimney existing and in use on or
after February 2, 1998 shall be permitted as long as... - ANSWERSSufficient draft is
available for each appliance, the chimney is lined and structurally intact, a carbon
monoxide detector installed near a bedroom, the solid fuel appliance has been listed by
an independent nationally recognized testing lab approved by the board, the solid fuel
burning appliance is installed in accordance with manufacturers specs.

Fuel oil licenses expire... - ANSWERSEvery 2 years

If the owner, occupant of any building or an installer neglects or refuses without
justification for more than ____ days to comply with any order of a state fuel inspector,
the person commits a civil violation for a fine of $100 each day neglected -
ANSWERS10

A person ordered by a state fuel inspector to correct a deficiency or to vacate a building
or structure may appeal the order by filling a written notice of appeal with the board
within ____ days after receipt of the order - ANSWERS30

An apprentice oil burner technician may assist in making oil installations and
repairing/servicing of oil burning equipment under the ____________ of a master or
journeyman oil tech who holds the same or higher authority - ANSWERSDirect
supervision

an apprentice oil burner tech may - ANSWERSBleed an oil burner without direct
supervision

An apprentice oil burner tech may clean oil burning equipment without direct supervision
if the apprentice has - ANSWERSSuccessfully completed 160hrs of training approved
by the board or completed at least one year of supervised oil burner work experience

An apprentice oil burner technician is permitted to replace a t stat without direct
supervision of a journeymen or master oil tech - ANSWERSFalse

After passing a journeymen/master oil burner exam, a technician has ____ days to file
for license before having to retest - ANSWERS2 years

,An apprentice oil burner tech who has completed atleast one year of supervised work
experience is permitted to ____________ without direct supervision -
ANSWERSBrush/vacuum heating appliance, replace nozzles/belts/filters/electrodes,
preform combustion efficiency test/test safety controls

The master oil burner tech is permitted to hook up to a water feed for a boiler________
- ANSWERSOnly to existing piping within the same room

A journeyman oil tech must at all times be under the indirect supervision of a master oil
technician who accepts full responsibility for the ___________ of the journeymen tech -
ANSWERSWork ethic, performance, training required

It is the duty of the master oil technician to _______ any installation work performed by
any licensee for whom the master is responsible for at the conclusion of an installation -
ANSWERSInspect personally

Whenever a master oil tech ceases to be an apprentice or journeymen's supervising
master, they must notify the ________ in writing, a copy of which shall be kept in both
the supervisee's and and former supervising masters file - ANSWERSBoard/supervisee

A master oil tech who sells, contracts, dispatches, or subcontracts any work or
installation to another master oil tech or other licensee is responsible for -
ANSWERSThe completion of the installation and the work performed

A master or journeyman oil tech may clean a combination solid fuel and oil unit and
service/repair the oil burner assembly without direct supervision if _________ -
ANSWERSThey are licensed as an apprentice solid fuel technician

A journeyman oil tech must at all times be under the indirect supervision of a master oil
burning who accepts _______ for the work ethic and performance of the journeyman oil
tech - ANSWERSFull responsibility

A journeyman or apprentice oil tech shall not work on any oil equipment if he -
ANSWERSDoes not have a supervising master

A journeyman oil tech shall not have more than _____ apprentice techs working under
the journeyman's direct supervision at one time - ANSWERS2

Where the circumstances or conditions of any particular installation are so unusual as to
render the strict application of a standard imposed by the boards rules impractical, the
board may permit such modifications provide - ANSWERSThere is equivalent degree of
safety, it is consistent with good engineering practice, it is reviewed and approved by
the senior fuel inspector

, When performing any service on a customers heating system, the licensee must notify
the property owner in writing of - ANSWERSAny code violations/make
recommendations to address them

When performing annual tune up on a heating system or new installation, a _________
must be conducted and a copy of results must be posted on site -
ANSWERSCombustion efficiency test

Whenever a furnace, direct fired water heater, or boiler is installed, _______ must be
brought into compliance of NFPA 31 and all other rules of the board - ANSWERSThe
total installation

________ is NOT required whenever a new burner is installed - ANSWERSProperly
installed service receptacle

A new heating system installation requires - ANSWERSA heat loss system design, a
system load calculation, a combustion efficiency test

When an emergency situation arises that does not allow adequate time to get the
chimney lined and or repaired before installing the new heating appliance, the licensee
may defer the required repairs for up to - ANSWERS90 days

The low water cutoff shall be installed - ANSWERSAbove the boiler crown sheet

A thermally operated oil shutoff valve must be located at the - ANSWERSOil burner and
oil supply tank

Shut off valves or other obstructive devices are prohibited between the boiler and -
ANSWERSSafety controls

A check valve may be used in the oil supply line from the tank to the burner -
ANSWERSTrue

When outside tanks are used, a ______ must be installed where the supply line enters
the building and where the oil line enters the room of the appliance -
ANSWERSThermally operated shutoff valve

When inside tanks are used and the oil supply tank is installed in a separate room a
thermally operated shutoff valve must be installed ________ - ANSWERSImmediately
inside the room as the oil line enters the room where the appliance is located

Whenever the oil supply is taken from the top of an oil tank, whether the oil tank is
outside or inside a ________ must be installed at the tank - ANSWERSThermally
operated shutoff valve

Document information

Uploaded on
September 8, 2025
Number of pages
31
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$19.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
papersmaster01
3.9
(74)
Sold
309
Followers
106
Items
14763
Last sold
1 week ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions