Master Oil Burner Test Study Guide 2025/2026 Accurate Questions And Correct Detailed Answers With Rationales || 100% Guaranteed Pass Newest Version

Document preview thumbnail
Preview 4 out of 61 pages

Master Oil Burner TEST STUDY GUIDE 2025/2026 ACCURATE QUESTIONS AND CORRECT DETAILED ANSWERS WITH RATIONALES || 100% GUARANTEED PASS NEWEST VERSION 1. The continued use of an existing connection of a solid fuel burning appliance to a chimney flue to which another appliance burning oil or solid fuel is connected for any chimney existing and in use before feb 2, 1998 shall be permitted assuming... - ANSWER Sufficent draft for each appliance, the chimney is lined and structuraly intact, a carbon monoxide detector is installed near a bedroom 2. The connection of a solid fuel burning appliance to a chimney flue to which another appliance burning oil or solid fuel is connected for any chimney existing and in use on or after February 2, 1998 shall be permitted as long as... - ANSWER Sufficient draft is available for each appliance, the chimney is lined and structurally intact, a carbon monoxide detector installed near a bedroom, the solid fuel appliance has been listed by an independent nationally recognized testing lab approved by the board, the solid fuel burning appliance is installed in accordance with manufacturers specs. 3. Fuel oil licenses expire... - ANSWER Every 2 years 4. If the owner, occupant of any building or an installer neglects or refuses without justification for more than ____ days to comply with any order of a state fuel inspector, the person commits a civil violation for a fine of $100 each day neglected - ANSWER 10 5. A person ordered by a state fuel inspector to correct a deficiency or to vacate a building or structure may appeal the order by filling a written notice of appeal with the board within ____ days after receipt of the order - ANSWER 30 6. An apprentice oil burner technician may assist in making oil installations and repairing/servicing of oil burning equipment under the ____________ of a master or journeyman oil tech who holds the same or higher authority - ANSWER Direct supervision 7. an apprentice oil burner tech may - ANSWER Bleed an oil burner without direct supervision 8. For a waste oil system, the minimum vent piping size is required to be ___ inches - ANSWER 1 1/4 inches 9. The minimum wall thickness for an outside rank is ___ gauge - ANSWER 12 gauge 10. The oil supply tank shall be mounted on steel pipe legs not exceeding ____ inches in height - ANSWER 12 inches 11. Manhole covers of 16 inches in diameter or larger shall be installed in the top of fuel oil tanks that have a capacity of _____ gallons or more - ANSWER 5000 gallons 12. A leaking oil tank may be temporarily repaired with a tank patch and any tank so repaired must be replaced within ____ days of the repair - ANSWER 30 days 13. The minimum oil tank size inside a building that requires a vent alarm is ____ gallons - ANSWER 11 gallons 14. Where a tank or tank system is not located in a dedicated room or enclosure, the maximum capacity in the building shall not exceed ____ gallons - ANSWER 1,320 gallons 15. An auxiliary rank shall be located at a level ____ of the supply tank from which it is filled - ANSWER Above the top 16. Plugs for oil tanks shall be constructed of - ANSWER Threaded steel 17. The concrete pad supporting an outside vertical oil tank shall rest on a bed of compacted gravel of ____ inches minimum - ANSWER 6 inches 18. The vent and fill pipe connecting to an oil tank must terminate at least __ feet from a window - ANSWER 2 feet 19. The overflow pipe on an auxiliary tank shall - ANSWER Not have any valve or an obstruction 20. The fuel oil tank must be pitched - ANSWER Toward the opening with a slope no less than 1/4" per foot 21. Two oil tanks connect with seperste fulls and one common vent, the common vent shall be - ANSWER Same size as largest individual tank vent 22. When converting fuel but leaving the oil tank for future use, what must be done - ANSWER The vent piping must remain intact and open to house, the full pipe must be removed completely/ plugged at the tank, the burner supply line must be removed and the valves on tank/burner must be capped or plugged 23. An _____ is to be installed between the outlet of the tank and the burner - ANSWER Oil filter, and two thermal shutoff valves ( one at tank one at burner) 24. Copper oil supply and return lines installed under cement, sub floors, or beneath any surface, shall be e faded in conduit a minimum of ____ pipe sizes larger than the oil supply and return lines - ANSWER 1 pipe size larger 25. The maine fuel board rules lists two types of thermally activated supply oil shut off valves as wheel and - ANSWER Lever 26. When inside tanks are used and the oil supply tank is installed in a seperate room a ____ must be installed where the line enters the room where appliance is located - ANSWER Thermally operated shutoff valve 27. In a centralized oil distribution system, a readily accessible and labeled _____ shall be installed either inside or outside the structure in each branch supply pipeline that enters a building or other structure - ANSWER Manually operated shutoff valve 28. A centralized oil distribution system with a vacuum reading in excess of 10hg at the burger requires a - ANSWER Transfer pump 29. A check valve for an oil like can not be installed in - ANSWER The return piping of a two pipe system 30. What gets oil from the tank to the burner - ANSWER Fuel unit (pump) 31. An _____ is used to prevent air particles from entering the return air supply - ANSWER Air filter 32. Cracks in the heat exchanger may be sealed for a maximum of ___ days with furnace cement or other materials (obsolete) - ANSWER 45 days 33. A service disconnect switch for the control of the burner while observing the flame shall be placed at the unit, within ________ - ANSWER Within arms reach of the technician 34. The low water control may be installed in the boiler at the level reccommended by the boiler manufacturer but in no case shall the low water control be installed - ANSWER Below the crown sheet 35. The emergency switch shall be located ______ of and adjacent to the entrance to the room where the appliance is located - ANSWER Outside 36. Hot water boilers installed or converted after January 1st 1996 must be provided with a - ANSWER Low water cutoff control 37. The settings on a fan control for a hot air furnace are - ANSWER High limit, blower (on), and blower (off)

Content preview

Master Oil Burner TEST STUDY GUIDE
2025/2026 ACCURATE QUESTIONS AND
CORRECT DETAILED ANSWERS WITH
RATIONALES || 100% GUARANTEED PASS
<NEWEST VERSION>

1. The continued use of an existing connection of a solid fuel burning
appliance to a chimney flue to which another appliance burning oil or solid
fuel is connected for any chimney existing and in use before feb 2, 1998
shall be permitted assuming... - ANSWER ✓ Sufficent draft for each
appliance, the chimney is lined and structuraly intact, a carbon monoxide
detector is installed near a bedroom

2. The connection of a solid fuel burning appliance to a chimney flue to which
another appliance burning oil or solid fuel is connected for any chimney
existing and in use on or after February 2, 1998 shall be permitted as long
as... - ANSWER ✓ Sufficient draft is available for each appliance, the
chimney is lined and structurally intact, a carbon monoxide detector installed
near a bedroom, the solid fuel appliance has been listed by an independent
nationally recognized testing lab approved by the board, the solid fuel
burning appliance is installed in accordance with manufacturers specs.

3. Fuel oil licenses expire... - ANSWER ✓ Every 2 years

4. If the owner, occupant of any building or an installer neglects or refuses
without justification for more than ____ days to comply with any order of a
state fuel inspector, the person commits a civil violation for a fine of $100
each day neglected - ANSWER ✓ 10

5. A person ordered by a state fuel inspector to correct a deficiency or to vacate
a building or structure may appeal the order by filling a written notice of
appeal with the board within ____ days after receipt of the order - ANSWER
✓ 30

,6. An apprentice oil burner technician may assist in making oil installations
and repairing/servicing of oil burning equipment under the ____________ of
a master or journeyman oil tech who holds the same or higher authority -
ANSWER ✓ Direct supervision

7. an apprentice oil burner tech may - ANSWER ✓ Bleed an oil burner without
direct supervision

8. For a waste oil system, the minimum vent piping size is required to be ___
inches - ANSWER ✓ 1 1/4 inches

9. The minimum wall thickness for an outside rank is ___ gauge - ANSWER ✓
12 gauge

10.The oil supply tank shall be mounted on steel pipe legs not exceeding ____
inches in height - ANSWER ✓ 12 inches

11.Manhole covers of 16 inches in diameter or larger shall be installed in the
top of fuel oil tanks that have a capacity of _____ gallons or more -
ANSWER ✓ 5000 gallons

12.A leaking oil tank may be temporarily repaired with a tank patch and any
tank so repaired must be replaced within ____ days of the repair - ANSWER
✓ 30 days

13.The minimum oil tank size inside a building that requires a vent alarm is
____ gallons - ANSWER ✓ 11 gallons

14.Where a tank or tank system is not located in a dedicated room or enclosure,
the maximum capacity in the building shall not exceed ____ gallons -
ANSWER ✓ 1,320 gallons

15.An auxiliary rank shall be located at a level ____ of the supply tank from
which it is filled - ANSWER ✓ Above the top

16.Plugs for oil tanks shall be constructed of - ANSWER ✓ Threaded steel

,17.The concrete pad supporting an outside vertical oil tank shall rest on a bed of
compacted gravel of ____ inches minimum - ANSWER ✓ 6 inches

18.The vent and fill pipe connecting to an oil tank must terminate at least __
feet from a window - ANSWER ✓ 2 feet

19.The overflow pipe on an auxiliary tank shall - ANSWER ✓ Not have any
valve or an obstruction

20.The fuel oil tank must be pitched - ANSWER ✓ Toward the opening with a
slope no less than 1/4" per foot

21.Two oil tanks connect with seperste fulls and one common vent, the
common vent shall be - ANSWER ✓ Same size as largest individual tank
vent

22.When converting fuel but leaving the oil tank for future use, what must be
done - ANSWER ✓ The vent piping must remain intact and open to house,
the full pipe must be removed completely/ plugged at the tank, the burner
supply line must be removed and the valves on tank/burner must be capped
or plugged

23.An _____ is to be installed between the outlet of the tank and the burner -
ANSWER ✓ Oil filter, and two thermal shutoff valves ( one at tank one at
burner)

24.Copper oil supply and return lines installed under cement, sub floors, or
beneath any surface, shall be e faded in conduit a minimum of ____ pipe
sizes larger than the oil supply and return lines - ANSWER ✓ 1 pipe size
larger

25.The maine fuel board rules lists two types of thermally activated supply oil
shut off valves as wheel and - ANSWER ✓ Lever

26.When inside tanks are used and the oil supply tank is installed in a seperate
room a ____ must be installed where the line enters the room where
appliance is located - ANSWER ✓ Thermally operated shutoff valve

, 27.In a centralized oil distribution system, a readily accessible and labeled
_____ shall be installed either inside or outside the structure in each branch
supply pipeline that enters a building or other structure - ANSWER ✓
Manually operated shutoff valve

28.A centralized oil distribution system with a vacuum reading in excess of
10hg at the burger requires a - ANSWER ✓ Transfer pump

29.A check valve for an oil like can not be installed in - ANSWER ✓ The
return piping of a two pipe system

30.What gets oil from the tank to the burner - ANSWER ✓ Fuel unit (pump)

31.An _____ is used to prevent air particles from entering the return air supply -
ANSWER ✓ Air filter

32.Cracks in the heat exchanger may be sealed for a maximum of ___ days with
furnace cement or other materials (obsolete) - ANSWER ✓ 45 days

33.A service disconnect switch for the control of the burner while observing the
flame shall be placed at the unit, within ________ - ANSWER ✓ Within
arms reach of the technician

34.The low water control may be installed in the boiler at the level
reccommended by the boiler manufacturer but in no case shall the low water
control be installed - ANSWER ✓ Below the crown sheet

35.The emergency switch shall be located ______ of and adjacent to the
entrance to the room where the appliance is located - ANSWER ✓ Outside

36.Hot water boilers installed or converted after January 1st 1996 must be
provided with a - ANSWER ✓ Low water cutoff control

37.The settings on a fan control for a hot air furnace are - ANSWER ✓ High
limit, blower (on), and blower (off)

Document information

Uploaded on
September 7, 2025
Number of pages
61
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$14.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
ProfBenjamin
3.8
(157)
Sold
789
Followers
19
Items
4135
Last sold
3 hours ago


Reviews from verified buyers

1 week ago

Thank you for your great feedback! Wishing you the best in your studies. If you ever need support with exam prep, assignments, research, test banks, or study resources, feel free to reach out or check out my page. I'm here to help! Warm regards




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions