Answers,2025 A+ Graded.
A room heater installed in either a sleeping area or public area shall be:
j j j j j j j j j j j j j
A. direct vent only
j j j
B. equipped with a regulator
j j j j
C. equipped with a fan
j j j j
D. equipped with an on / off switch on the wall - CORRECT ANSWER✔✔B
j j j j j j j j j j j j j
What type of vent must be used when the vent of a wall furnace will be concealed in a partition wall?
j j j j j j j j j j j j j j j j j j j j
A. B vent
j j
B. L vent
j j
C. BH vent
j j
D. BW vent - CORRECT ANSWER✔✔D
j j j j j
,Single wall vent connectors:
j j j
A. may pass through floors, ceilings or roofs provided a metal thimble is used
j j j j j j j j j j j j j
B. may pass through floors, ceilings or roofs provided the required minimum distance from combustible
j j j j j j j j j j j j j j
material is maintained
j j j
C. may pass through floors, ceilings or roofs provided they are insulated
j j j j j j j j j j j
D. shall not pass through floors, ceilings or roofs - CORRECT ANSWER✔✔D
j j j j j j j j j j j
BW vent shall be used only with an approved:
j j j j j j j j
A. decorative appliance
j j
B. down flow furnace
j j j
C. revertible flue boiler
j j j
D. recessed wall furnace - CORRECT ANSWER✔✔D
j j j j j j
What must be done during the installation of a gas log fireplace?
j j j j j j j j j j j
A. Make sure there is a metal mesh screen in front of the fireplace
j j j j j j j j j j j j j
B. Secure the chimney damper in the open position
j j j j j j j j
C. Install a pressure regulator
j j j j
D. Install a metal chimney liner - CORRECT ANSWER✔✔B
j j j j j j j j
When can a certified hose be used to connect a construction heater to temporary piping?
j j j j j j j j j j j j j j
A. Only if a lever handle shut off valve is installed upstream of the hose
j j j j j j j j j j j j j j
B. Only if the hose is 15 feet long
j j j j j j j j
C. Never - CORRECT ANSWER✔✔A
j j j j
Which of the following is acceptable when a fireplace insert is installed?
j j j j j j j j j j j
,A. A metal chimney linear
j j j j
B. The existing fireplace flue
j j j j
C. BW vent
j j
D. A tile lined fireplace flue? - CORRECT ANSWER✔✔A
j j j j j j j j
An unvented infra-red heater can be installed in ________ application
j j j j j j j j j j
A. A warehouse
j j
B. A commercial building
j j j j
C. An industrial building
j j j
D. All of the above - CORRECT ANSWER✔✔D
j j j j j j j
Dirt pockets are required on:
j j j j
A. Decorative appliances
j j
B. Gas logs
j j
C. Room heaters
j j
D. None of the available choices - CORRECT ANSWER✔✔D
j j j j j j j j
What diameter and length of a dirt pocket is required when a drop line is 3-inch diameter?
j j j j j j j j j j j j j j j j
A. 3 inch diameter by 3 inches long
j j j j j j j
B. 1 inch diameter by 3 inches long
j j j j j j j
C. 3/4 inch diameter by 3 inches long
j j j j j j j
D. 2 inch diameter by 3 inches long - CORRECT ANSWER✔✔D
j j j j j j j j j j
What type of room heater maybe installed in a bathroom?
j j j j j j j j j
A. Natural draft
j j
, B. Direct fired
j j
C. Forced draft
j j
D. Direct vent - CORRECT ANSWER✔✔D
j j j j j
What safety control protects a steam boiler if the condensate pump fails to return water to the boiler?
j j j j j j j j j j j j j j j j j
A. High pressure limit control
j j j j
B. Low pressure limit control
j j j j
C. Flame safeguard control
j j j
D. Low water cut off - CORRECT ANSWER✔✔D
j j j j j j j
The relief valve for a residential low-pressure hot water boiler system should be?
j j j j j j j j j j j j
A. 14.7 psia
j j
B. 15 psia
j j j
C. 30 psig
j j
D. 30 psia - CORRECT ANSWER✔✔C
j j j j j
A backflow prevent used in a boiler system should be located in the:
j j j j j j j j j j j j
A. Over flow line connected to the drain
j j j j j j j
B. Return line close to the boiler
j j j j j j
C. 1/4" line connecting the boiler and cushion tank
j j j j j j j j
D. Make up water line to the system - CORRECT ANSWER✔✔B
j j j j j j j j j j
Automatic chlorinators must be installed: j j j j
A. upstream of the heater
j j j j
B. downstream of the heater
j j j j