What is G? - -The velocity gradient used in coagulation and flocculation.
What is tapered flocculation? - -Multiple stages have a decreasing velocity gradient in
each successive stage. This is to help form floc and prevent it from breaking
Type II Settling - -- Particles adhere to each other as they bump into each other
- Faster settling particles overtake those that settle more slowly
- Large number of particles form a blanket that overtake other particles
What is the detention time for a sedimentation basin? - -1.5-4 hrs
How is granular filtration layered? Why? - -Anthracite is the top layer and sand is the
bottom layer. It is layered this way to increase the filter effectiveness: Larger particles
get trapped first. It is also due to the backwash process: the sand settles first because it
is denser
What is ripening? - -Occurs immediately after backwashing. The effluent turbidity rises
to a peak and then falls
How are particles captured in rapid granular filtration? - -- Particles are removed by
straining (particles are larger than the void spaces in the filter)
- Van der Waal forces (attractive close range molecular forces)
What is depth filtration? - -Using the whole bed to filter out the particles (large particles
are filtered out first and smaller particles as you go down in layers). Utilizes Van der
Waal forces.
Where is a cross-flow configuration used? - -In industrial wastewater treatment
Where is a dead-end configuration used? - -In municipal wastewater treatment
What is the filtration mechanism of rapid granular filtration? - -Depth filtration
What is the filtration mechanism of membrane filtration? - -Straining
What are some important design parameters of membrane filtration? - -- A membrane
filtration plant needs 100 times the filter area of a rapid granular filtration plant
- Membrane filtration does not require pretreatment
- Membrane filtration performance is not affected by the concentration of the feed water
Water