100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4,6 TrustPilot
logo-home
Examen

NCLE ADVANCED CERTIFICATION NCLE ADVANCED CERTIFICATION EXAM STUDY GUIDE. GRADED A+. QUESTIONS AND 100% VERIFIED ANSWERS. LATEST 2025/2026 UPDATE

Puntuación
5.0
(1)
Vendido
1
Páginas
104
Grado
A+
Subido en
27-08-2025
Escrito en
2025/2026

NCLE ADVANCED CERTIFICATION NCLE ADVANCED CERTIFICATION EXAM STUDY GUIDE. GRADED A+. QUESTIONS AND 100% VERIFIED ANSWERS. LATEST 2025/2026 UPDATE NCLE ADVANCED CERTIFICATION NCLE ADVANCED CERTIFICATION EXAM STUDY GUIDE. GRADED A+. QUESTIONS AND 100% VERIFIED ANSWERS. LATEST 2025/2026 UPDATE NCLE ADVANCED CERTIFICATION NCLE ADVANCED CERTIFICATION EXAM STUDY GUIDE. GRADED A+. QUESTIONS AND 100% VERIFIED ANSWERS. LATEST 2025/2026 UPDATE

Mostrar más Leer menos
Institución
NCLE ADVANCED CERTIFICATION NCLE ADVANCED CER
Grado
NCLE ADVANCED CERTIFICATION NCLE ADVANCED CER

Vista previa del contenido

NCLE ADVANCED CERTIFICATION


NCLE ADVANCED
CERTIFICATION EXAM STUDY
GUIDE. GRADED A+.
QUESTIONS AND 100%
VERIFIED ANSWERS. LATEST
2025/2026 UPDATE



The answer is D.

The posterior optical zone will directly affect the lens to cornea relationship of a rigid
gas permeable lens. If the posterior optical zone is steepened, it will increase the
sagittal depth. If it is flattened, it will decrease the sagittal depth. Changing the
power, which is accomplished by changing the anterior optical zone, will not affect
the sagittal depth of the lens, nor will changing its edge design. - Answer 1. The
sagittal depth of a rigid gas permeable contact lens can be altered without changing
the diameter by:

A. Changing the power
B. Changing the edge design
C. Changing the radius of curvature of the anterior optical zone
D. Changing the radius of curvature of the posterior optical zone

The answer is A.

A lens is truncated by removing a segment of the lower edge of a contact lens. This
creates a straight edge that interacts with the lower lid and aids in lens positioning.
Of the lens designs listed in the question, the only one that requires precise
positioning of its optical portions is a translating bifocal lens. - Answer 2. A truncation
is used on a rigid gas permeable contact lens to help enhance the performance of
which type of design?

A. Bifocal
B. Aphakic
C. Bitoric
D. Keratoconus

,NCLE ADVANCED CERTIFICATION
The answer is B.

,NCLE ADVANCED CERTIFICATION
A lenticular or myoflange design will decrease the mass of an aphakic lens as well
as increase the edge profile, which allows it to interact more with the upper lid and
aid in positioning of the lens. - Answer 3. The mass of an aphakic rigid gas
permeable contact lens can be reduced by making the lens design:

A. Spherical
B. Lenticular
C. Tricurve
D. Aspheric

The answer is B.

Increasing the optical zone diameter and increasing the overall lens diameter will
both tighten and steepen the relationship of the lens to the cornea. Decreasing the
optic zone diameter will serve to flatten and loosen the lens to cornea relationship.
Using a prism-ballasted lens design will not affect the lens to cornea relationship as it
relates to sagittal depth. - Answer 4. In order to tighten the fit of a rigid gas
permeable lens you can:
I. Increase the optical zone diameter
2. Decrease the optical zone diameter
3. Increase the overall lens diameter
4. Use a prism ballasted lens design

A. 3 only
B. 1&3
C. 2 only
D. 2&3

The answer is D.

A hyperflange will decrease edge thickness as well as lens awareness . Aspheric
peripheral curves change the posterior design of the lens but do not reduce edge
thickness. A higher Dk material will not change the overall lens edge thickness. A
myoflange will actually add thickness to the lens edge and is used for high plus
lenses not high minus lenses. - Answer 5. A high minus rigid gas permeable lens will
be thin centrally with relatively thick edges. To reduce the edge thickness, and
increase overall comfort, use:

A. Aspheric peripheral curves
B. A myoflange
C. A higher Dk material
D. A hyperflange

The answer is C.

One would rarely polish or attempt to manipulate the central posterior surface of a
rigid lens. Applying polishing pressure to the mid-peripheral and the peripheral
anterior surface would add plus power. Applying polishing pressure to the central
anterior surface would add minus power. - Answer 6. To add minus power to a rigid
contact lens with a rotating modifying spindle, one would:

, NCLE ADVANCED CERTIFICATION
A. Polish the posterior surface of the rigid lens
B. Polish the mid peripheral anterior surface
C. Polish the central anterior surface
D. Polish the peripheral anterior surface

The answer is A.

The keratometer readings indicate the need for a spherical back surface, which
would rule out the use of a bitoric lens. A soft spherical lens would not correct the
moderate amount of refractive astigmatism that is present, nor would the spherical
rigid gas permeable lens. A front surface toric RGP would best meet this patient's
needs since it has a spherical back surface, but has a toric front surface which would
correct the residual astigmatism. - Answer 7. Which lens design would provide the
best visual acuity for a patient with the following information?
K's 42.00@ 180/ 42.50@90
Rx -6.75 +1.75 cx 90

A. Front surface toric rigid gas permeable
B. Spherical rigid gas permeable
C. Soft sphere
D. Bitoric rigid gas permeable

The answer is A.

The wetting angle of a rigid gas permeable material describes how a fluid spreads
over the surface. It is important to remember, however, that wetting angle is a
description of the material outside of the patient's natural ocular environment. Within
minutes of insertion, a rigid lens is encapsulated in the natural tear mucin and the
wetting angle of the material is no longer important. - Answer 8. Which of the
following describes the angle that the edge of a bead of water makes with the
surface of a plastic?

A. Wetting angle
B. Surface angle
C. Bead angle
D. Reflection angle

The answer is B.

The back surface of a rigid lens will usually correct only the astigmatism that is found
on the surface of the cornea. Therefore, when there is significantly more astigmatism
in the refraction than on the surface of the cornea, residual astigmatism is
anticipated. - Answer 9. If a patient has 1.50 D of refractive cylinder and keratometer
readings of 44.00@ 180/ 44 .50 @ 90, a spherical rigid gas permeable lens will:

A. Give the patient their best correctable vision
B. Usually result in residual astigmatism
C. Fit poorly
D. Be uncomfortable

Escuela, estudio y materia

Institución
NCLE ADVANCED CERTIFICATION NCLE ADVANCED CER
Grado
NCLE ADVANCED CERTIFICATION NCLE ADVANCED CER

Información del documento

Subido en
27 de agosto de 2025
Número de páginas
104
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

$22.99
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Reseñas de compradores verificados

Se muestran los comentarios
3 meses hace

2 meses hace

Thank you for the review.

5.0

1 reseñas

5
1
4
0
3
0
2
0
1
0
Reseñas confiables sobre Stuvia

Todas las reseñas las realizan usuarios reales de Stuvia después de compras verificadas.

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
BESTGRADE32 Chamberlain College Of Nursing
Ver perfil
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
10
Miembro desde
1 año
Número de seguidores
2
Documentos
1986
Última venta
6 días hace
BESTGRADE32

EXCELLENT HOMEWORK HELP AND TUTORING,ALL KIND OF QUIZ AND EXAMS WITH GUARANTEE OF A EXCELLENT HOMEWORK HELP AND TUTORING,ALL KIND OF QUIZ AND EXAMS WITH GUARANTEE OF A Am an expert on major courses especially;psychology,nursing,human resource management and mathematics assisting students with quality work is my first priority.i ensure scholarly standards in my documents.

3.0

3 reseñas

5
1
4
0
3
1
2
0
1
1

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes