Construction 3
INTRO

- construction 3: site, space plan and services

Lecture 01 - Site Design (use of sun, wind (and precipitation))

Principles & theoretical background

- natural factors:
- sunlight: electromagnetic radiotion – infrared, visible & UV light
-> diffused – atmosphere
- measure: Solar irradiance [W/m²]: power/ unit area
(a) mean solar irradiation -> top of Earth's atmosphere -->
(b) Annual insolation -> reach Earth surface after atmosphere
-> used most by designers
-> measured with pyranometer -->
<- hrs of sunlight/ day -> belgium:
-> winter solstice ) day least light – base for design (critical)

- Wind: in Belgium no cyclones/ hurricanes -> take less into account
- classification: spatial scale, speed and direction
- long duration winds: breeze, gale, storm, hurricane
- design conditions: use https://globalwindatlas.info/en/area/Belgium
for parameters place -> consider height – building
- measure: anemometers (most often w rotating cups – propellers)
-> by propagation s - ultrasnd signal/ effect vent on heated wire

- Temperature: chart L: average surface air temperature
- design parameter: winter solstice
- rise of temp since industrial revolution
- In cities – extra increase temp
- buildings, pavement, -- vegetation, activities, energy usage…
-> Be less than ex. LA, NYC …

- Precipitation: Be: moderate all year round/ Equator: ++ but extreme seasons
-measure: rain gauge or pluviometer

- precipitation and temperature classification: Koppen Climate classification sys
-> based temp, precip and vegetation patterns -> Be= Cfb (temperate oceanic)

- humidity= concentration of water vapour present in air
- relative humidity: ratio 2 pressures; partial pressure of water vapour in
ambient sat pressure of water at temp of ambient
-> most used in design
- measure: hygrometer (- Da Vinci) – humidistat (humid-triggered switch)

- Meteorolical stations: RMI – 20 station BE
(www.meteo.be/en/weather/observations/belgium)

-> other factor(s): Vapour diffusion from in- to outside (noise, fire, earthquake –
less in Belgium)

1

, Culture and history

- ancient city of Olynthus (Greece): oriented towards sun
- Code of Justinian: sunshine may not be blocked from reaching a helio-caminus
<- arabic/ middle eastern cities: high, small streets -> bend sunlight – reduce temp
- asia: used L-shaped windbreakers – protect cold wind -->
- America (honduras): passive vent by setting houses far apart ->

Current practice

- main focus: sunlight (thermal energy) & wind (kinetic energy)
- other focusses: site selection; wind and site design; sun-driven (solar acces; shadow patterns;
site planning; solar zoning)

- site selection: keep in mind: tilt earth’s axis, seasons (winter solstice as design base)
-> orientation
- slope different condition and sun:
- mntn: shaded slope inconvenient (at least Be)

- solar acces (boundry): conical surface generated – sunrays (winter)
- best no large trees too close to south of building – block sun (panels, daylight)
- shadow patterns: desirable – no overlap
-> angle 45°, length: h.7 (in belgium) -> in middle: h.2,5
- streets: east-west streets best, try avoid north-south
-> try avoid uneven setbacks :




- when solar acces not possible – can use roof windows
- maquette see lighting - heliodon

- wind & site design:
- a small reduct.- wind velocity (wind-breaker (tree)) -> high reduct of heat loss
- when gap -> wind velocity % increases (consider 4 ppl walk thru – comfort)
- ex. pilotis
- tall building -> ground level redirection wind
-> can be avoided by extensions
- tallest buildings best -> south => protect cold northern wind + no block sunlight
- protect wind in cold climate: row housing or cluster housing
-> hot climates: lead wind thru home (natural vent)-> use vegetation -->
-> use staggered buildings (geschrankt) – promote nat vent
- maximize summer wind -> trees w high canopies




2

Geschreven voor

Instelling
Studie
Vak

Documentinformatie

Geüpload op
26 augustus 2025
Aantal pagina's
13
Geschreven in
2024/2025
Type
SAMENVATTING

Onderwerpen

$7.74
Krijg toegang tot het volledige document:

100% tevredenheidsgarantie
Direct beschikbaar na je betaling
Lees online óf als PDF
Geen vaste maandelijkse kosten


Ook beschikbaar in voordeelbundel

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
emelineb Universiteit Antwerpen
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
32
Lid sinds
1 jaar
Aantal volgers
2
Documenten
19
Laatst verkocht
21 uur geleden
Architectuur UA

Studente Architectuur aan de UA, startjaar 2023

3.8

6 beoordelingen

5
0
4
5
3
1
2
0
1
0

Populaire documenten

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Veelgestelde vragen