Journeyman Plumbing Test Study Guide Questions with Correct Answers

Document preview thumbnail
Preview 3 out of 20 pages

more restrictive provisions apply - ANSWERSwhere conflicts occur between code and manufacture instructions. what shall be 3rd party certified as conforming to NSF 14 - ANSWERSall plastic pipe, fittings and components. all strainer plates on drain inlets shall be designed and installed so that all openings are..? - ANSWERSnot greater than 1/2 inch (12.7) in least dimension. pipes through foundation walls need..? - ANSWERSa relieving arch or a pipe sleeve which is 2 pipe sized bigger. waterproofing joints at the roof and around vent pipes shall be made water tight by use of....? - ANSWERSlead, copper, steel, aluminum, plastic, or approved flashing/flashing material. exterior wall opening must be made...? - ANSWERSwater tight. T or F: buried piping needs to be supported throughout it entire length. - ANSWERSTrue When backfilling the trench, that was over excavated - ANSWERSbackfill up to installation level of bottom of pipe w/sand or gravel in layers no more than 6" in depth and compacted after each placement. when a rock is encountered trenching - ANSWERSremoved to not less than 3 inches below installation level. backfill with tamped sand. when backfilling pipe systems crown of the pipe must be covered by...? - ANSWERS12 inches of tamped earth. T or F: truss members and components may be cut, drilled, notched or spliced. - ANSWERSfalse. unless they obtain approval from a design professional. hanger spacing: steel pipe - ANSWERSevery 12 ft horizontal 15 vertical where hot water piping is bundled w/cold or hot water piping... - ANSWERSeach hot water pipe shall be insulated. pipe sizes great than 4 inch need restraints for drain pipes at.. - ANSWERSall changes in direction and changes in diameter greater that 2 pipe sizes. testing gauge required for 10 psi or less? - ANSWERShas increments of .10psi or less. testing gauge required for 10 psi up to 100 psi - ANSWERSincrements of 1 psi testing gauge required for greater than 100 psi - ANSWERSincrements of 2 psi tests shall last not less than..? - ANSWERS15 minutes 2 ways you can test a drainage system. - ANSWERSin its entirety or in sections. if testing entire drainage system, all openings in piping shall be tightly closed except..? - ANSWERSthe highest opening, and system shall be filled to point of overflowing. if drainage system is tested in sections, no section shall be tested with less than..? - ANSWERSa 10 foot head of water. T or F: plastic piping shall not be tested using air. - ANSWERStrue. when testing drainage system w/air, force air into system until there is... - ANSWERSa uniform pressure of 5 psi or sufficient to balance a 10 inch colum of mercury. (no air test on plastic piping ) drainage and vent final test shall be... - ANSWERSvisual (smoke) gravity sewer test consists of plugging building sewer at point of connection w/ public sewer, filling building sewer with water testing with not less than... - ANSWERS10 foot head of water. maintain for 15 minutes. shower liner test. fill with water not less than... - ANSWERS2 inches measured at threshold. hanger spacing: lead pipe - ANSWERScontinuous horizontal, 4 feet vertical liquid combustion byproducts of condensing appliances shall be collected and discharged to... - ANSWERSan approved plumbing fixture or disposal area in accordance with manufacturer's instructions. appliances containing evaporator or cooling coils must be provided with... - ANSWERScondensate drain systems.

Content preview

Journeyman Plumbing Test Study
Guide Questions with Correct
Answers
more restrictive provisions apply - ANSWERSwhere conflicts occur between code and
manufacture instructions.

what shall be 3rd party certified as conforming to NSF 14 - ANSWERSall plastic pipe,
fittings and components.

all strainer plates on drain inlets shall be designed and installed so that all openings
are..? - ANSWERSnot greater than 1/2 inch (12.7) in least dimension.

pipes through foundation walls need..? - ANSWERSa relieving arch or a pipe sleeve
which is 2 pipe sized bigger.

waterproofing joints at the roof and around vent pipes shall be made water tight by use
of....? - ANSWERSlead, copper, steel, aluminum, plastic, or approved flashing/flashing
material.

exterior wall opening must be made...? - ANSWERSwater tight.

T or F: buried piping needs to be supported throughout it entire length. -
ANSWERSTrue

When backfilling the trench, that was over excavated - ANSWERSbackfill up to
installation level of bottom of pipe w/sand or gravel in layers no more than 6" in depth
and compacted after each placement.

when a rock is encountered trenching - ANSWERSremoved to not less than 3 inches
below installation level. backfill with tamped sand.

when backfilling pipe systems crown of the pipe must be covered by...? - ANSWERS12
inches of tamped earth.

T or F: truss members and components may be cut, drilled, notched or spliced. -
ANSWERSfalse. unless they obtain approval from a design professional.

hanger spacing: steel pipe - ANSWERSevery 12 ft horizontal 15 vertical

where hot water piping is bundled w/cold or hot water piping... - ANSWERSeach hot
water pipe shall be insulated.

,pipe sizes great than 4 inch need restraints for drain pipes at.. - ANSWERSall changes
in direction and changes in diameter greater that 2 pipe sizes.

testing gauge required for 10 psi or less? - ANSWERShas increments of .10psi or less.

testing gauge required for >10 psi up to 100 psi - ANSWERSincrements of 1 psi

testing gauge required for greater than 100 psi - ANSWERSincrements of 2 psi

tests shall last not less than..? - ANSWERS15 minutes

2 ways you can test a drainage system. - ANSWERSin its entirety or in sections.

if testing entire drainage system, all openings in piping shall be tightly closed except..? -
ANSWERSthe highest opening, and system shall be filled to point of overflowing.

if drainage system is tested in sections, no section shall be tested with less than..? -
ANSWERSa 10 foot head of water.

T or F: plastic piping shall not be tested using air. - ANSWERStrue.

when testing drainage system w/air, force air into system until there is... - ANSWERSa
uniform pressure of 5 psi or sufficient to balance a 10 inch colum of mercury. (no air test
on plastic piping )

drainage and vent final test shall be... - ANSWERSvisual (smoke)

gravity sewer test consists of plugging building sewer at point of connection w/ public
sewer, filling building sewer with water testing with not less than... - ANSWERS10 foot
head of water. maintain for 15 minutes.

shower liner test. fill with water not less than... - ANSWERS2 inches measured at
threshold.

hanger spacing: lead pipe - ANSWERScontinuous horizontal, 4 feet vertical

liquid combustion byproducts of condensing appliances shall be collected and
discharged to... - ANSWERSan approved plumbing fixture or disposal area in
accordance with manufacturer's instructions.

appliances containing evaporator or cooling coils must be provided with... -
ANSWERScondensate drain systems.

, condensate disposal piping shall maintain a horizontal slope in the direction of
discharge not less than - ANSWERS1/8 unit vertical in 12 units horizontal (1 percent
slope)

sheet copper for general applications shall not weigh less than... - ANSWERS12 oz per
sq. ft.

T or F: separate facilities shall be required for dwelling units and sleeping units. -
ANSWERSfalse

separate facilities are not required in structures or tenant spaces with a total occupant
load including employees and customers of... - ANSWERS15 or fewer.

separate facilities are not required in Mercantile occupancies in which the max occupant
load is.. - ANSWERS100 or fewer

in occupancies other than malls, the public/employee toilet facilities shall be located...? -
ANSWERSno more than 1 story above or below and path of travel not more than 500
feet.

where should public and employee toilet facilities be located in malls? - ANSWERSnot
more than 1 story above or below with path of travel no more than 300 feet.

what type of facilities shall be in excess of required minimum? - ANSWERSpay facilities

T or F: egress door for multiple occupant toilet room other than family or assisted use
rooms should be lockable from the inside - ANSWERSFalse

directional signage to required public toilet facilities. - ANSWERSposted in a
lobby,corridor, aisle or similar space so the sign can be readily seen from main
entrance.

drinking fountains distance from individual tenant space that doesn't have a drinking
fountain. - ANSWERSwithin 500 feet of the most remote location in tenant space, and
not more than one story above or below. if in a mall within 300 feet.

accessible plumbing fixtures shall be installed with ____, ____,____ and _____ in
accordance with ICC A117.1 - ANSWERSclearances, heights, spacing and
areangements

water supply and drain pipes under accessible lavatories and sinks shall be ____? -
ANSWERScovered or otherwise configured to protect against contact.

the supply lines and fittings for every plumbing fixture shall be installed so as to prevent
what? - ANSWERSbackflow

Document information

Uploaded on
August 22, 2025
Number of pages
20
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$16.29

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Bestgrades2
3.8
(5)
Sold
38
Followers
0
Items
5114
Last sold
3 weeks ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions