Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Exam (elaborations)

Radiation Therapy Registry Study Guide || Graded A+.

Rating
-
Sold
-
Pages
32
Grade
A+
Uploaded on
20-08-2025
Written in
2025/2026

Which is not used to achieve a uniform dose by compensating for missing or curved tissue? A. wedges B. shielding blocks C. MLC D. Bolus correct answers C. MLC Collimator indicator agreement checks should be performed ___ and have a tolerance of _____ correct answers monthly : 1 degree A light/radiation field coincidence check should be performed _____ and has a tolerance of ________ correct answers monthly : 2 mm MLC transmission should be within: correct answers .5% The xray output constancy measured during daily warm up procedure of a medical accelerator has a tolerance of +/- ? correct answers 3% It is recommended that medical accelerators with arc therapy capability require dosimetry checks _____ correct answers annually Multileaf collimators must be thick enough to reduce beam transmission through the leaf itself to less than? correct answers 2% Mechanical accuracy for stereotactic radiosurgery with regard to isocenter displacement from the target is : +/- ? correct answers +/- 1 mm

Show more Read less
Institution
Radiation Therapy
Course
Radiation Therapy

Content preview

Radiation Therapy Registry Study Guide || Graded A+.


Which is not used to achieve a uniform dose by compensating for missing or curved tissue?
A. wedges
B. shielding blocks
C. MLC
D. Bolus correct answers C. MLC


Collimator indicator agreement checks should be performed ___ and have a tolerance of _____
correct answers monthly : 1 degree


A light/radiation field coincidence check should be performed _____ and has a tolerance of
________ correct answers monthly : 2 mm


MLC transmission should be within: correct answers .5%


The xray output constancy measured during daily warm up procedure of a medical accelerator
has a tolerance of +/- ? correct answers 3%


It is recommended that medical accelerators with arc therapy capability require dosimetry checks
_____ correct answers annually


Multileaf collimators must be thick enough to reduce beam transmission through the leaf itself to
less than? correct answers 2%


Mechanical accuracy for stereotactic radiosurgery with regard to isocenter displacement from the
target is : +/- ? correct answers +/- 1 mm

,The recommended tolerance for CT number accuracy for water checked on a daily basis is?
correct answers +/- 5HU


Level II axillary lymph nodes lie: correct answers under the pectoralis muscle


As SSD increases, TAR _____ correct answers remains the same


What all applies to the concept of isocenter? correct answers - fixed reference point in space;
- couch, collimator and gantry all rotate about the isocenter;
- on a LINAC it is 100cm from the target


What factors affect the shape of the isodose curve? correct answers - beam energy
- SSD
- Field Size
- Source Size


The central Hounsfield Unit within a group of CT numbers is known as: correct answers Window
Level


Using a system of closed circuit cameras and intercoms during radiation treatments is
considered? correct answers indirect monitoring


What type of lung cancer is centrally located in the right or left mainstem bronchus? correct
answers squamous cell carcinoma


Which studies involve ionizing radiation? correct answers radiography, CT, Nuc Med Bone scan
(Not doppler/sonography/MRI)

,Ratio of dose rate with a scattering medium to the dose rate at the same point without a medium
(in air) at dmax. correct answers backscatter factor


Aka TAR at Dmax


Lymph leaving the cisterna chyli travels to the: correct answers Thoracic Duct


During a set up of a left breast tx, the therapist did not cover up the patient's right breast. This is
considered: correct answers invasion of privacy


As SSD increases, PDD correct answers increases


The TNM staging system assists in all of the following ways except: correct answers the
agressiveness of the tumor


In radiation therapy, there are two communication standards that are applied to the electronic
medical record for transfer of data and images. those are (2 answers) correct answers DICOM &
HL7


During what gestation period would radiation most likely cause death to an embryo or fetus?
correct answers 2-3 weeks and after 20 weeks


The TD 5/5 for lens of the eye is? correct answers 500 cGy


The production of free radicals in living tissue most often occurs from irradiation of correct
answers water


The para-aortic lymph nodes become the common iliac nodes at the vertebral level of correct
answers L4

, The range of penetration of 12 MEV electrons is correct answers 6 cm


The addition of programmable localization lasers to a CT simulator enable the radiation
oncology team to: correct answers Choose the exact isocenter during the simulation process in
order to hopefully reduce the amount of port films required on the patient's first day.


The most common subtype of renal cancer is correct answers Clear cell carcinoma


The NCRP report No 116 recommends the total dose equivalent limit for a fetus-embryo not
exceed: correct answers 5 mSv
or
0.5 rem


Which of the following cells are most radio-sensitive? correct answers erythroblasts


Dry and/or moist desquamation typically begins to occur at doses of: correct answers 4000-6000
cGy


Transportation of radioactive materials is primarily the concern of the: correct answers
Department of Transportation


Absorbed dose at a depth divided by the dose at D/max at different distances from the radiation
source is? correct answers PDD


If you are transferring a patient from a wheelchair to the table you should? correct answers - Put
one foot slightly in front of the other
- flex your knees
- stand directly in front of the patient

Written for

Institution
Radiation Therapy
Course
Radiation Therapy

Document information

Uploaded on
August 20, 2025
Number of pages
32
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$15.89
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF


Also available in package deal

Thumbnail
Package deal
Radiation Therapy || Get it Correct.
-
31 2025
$ 171.23 More info

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
SirAnton NURSING, ECONOMICS, MATHEMATICS, BIOLOGY, AND HISTORY MATERIALS BEST TUTORING, HOMEWORK HELP, EXAMS, TESTS, AND STUDY GUIDE MATERIALS WITH GUARANTEED A+ I am a dedicated medical practitioner with diverse knowledge in matters
View profile
Follow You need to be logged in order to follow users or courses
Sold
786
Member since
3 year
Number of followers
438
Documents
39304
Last sold
2 weeks ago
Reign Supreme Scholarly || Enlightened.

Get your revised study materials available here and elevate your educational outcomes. I have numerous verified learning materials (Research, Exams Questions and answers, Assignments, notes etc) for different courses guaranteed to boost your academic results. I am dedicated to offering you the best and unique learning content. You are encouraged to inquire further assistance from this end whenever need be. Kindly remember to leave your review, understanding your satisfaction is essential . We highly appreciate clients who always come back for more of the study content we offer, you are extremely valued. All the best.

Read more Read less
3.7

116 reviews

5
49
4
20
3
23
2
8
1
16

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions