This system keeps supply air always at the same temperature, and delivers more or less
air as required to maintain or change the temperature in the space - answer ( )Constant
volume

(x)Variable air volume

( )Fan-based temperature control

( )Constant density

This system always delivers the same airflow but the air may be hotter or colder as
required to maintain or change the temperature in the space - answer (x)Constant
volume

( )Variable air volume

( )Thermostatic temperature control

( )Constant density

How can a single-duct system be divided into zones with different thermal
requirements? - answer ( )Reheat method - Cool the airflow to meet the needs of the
zone that needs most cooling, and then reheat it for the other zones using a heating
terminal at the point of entry to each space

( )VAV method - Cool the airflow to meet the needs of the zone that needs most cooling,
and then reduce the volume of air supplied to the other zones using a VAV box at the
point of entry to each space

( )Provide separate hot and cold air flows to each zone

(x)Either reheat method or VAV method could be used

An air-side economizer is used when: - answer ( )Most zones in the system require
cooling and only one or two require heating. The system makes cold air to satisfy the
majority of the zones and reheat is applied in the one or two zones that need heating

( )The return air from the space is relatively free from contaminants and CO2. The return
air is then recycled into the space, since it has already been conditioned and will require
less energy to treat.

( )The price of electricity from the grid is greater than the price of on-site generation. An
on-site generator is then used to produce electricity for air-conditioning at lower cost.

, (x)The enthalpy of outdoor air is lower than that of the return air. The outdoor air is then
used to provide free cooling, by bringing in more outdoor air than is required to meet
needs for fresh air ventilation.

Reheat systems have many advantages - they permit simple zone control for areas with
different loads, can provide heating or cooling to different areas at the same time,
maintains close control over humidity and offers flexibility when zones are selected at
design stage. What is the main disadvantage? - answer (x)The system uses energy to
cool air and then uses energy again to heat it back up. This is wasteful of energy and
uneconomical

( )The system can't be easily changed to provide more zones once it is installed.

( )The system can't be easily metered to determine which zones consumed the most
energy

( )The system can't be easily adapted to allow for heat recovery.

Which of the following is/are disadvantages of a zoned variable air volume system? -
answer ( )Poor energy efficiency since so much energy is used for fans

(x)Possibly poor ventilation if a zone does not require much air for cooling

( )Difficult to adapt to an air-side economizer

( )Difficult to control to achieve the desired effect in each zone

Which of the following approaches has the lowest energy consumption: - answer
(x)Single-duct zoned variable air volume

( )Single-duct zoned-reheat constant volume

( )Dual-duct

( )Multizone

Select the answer which best describes this system. Air is supplied to an undivided
conditioned space by a system capable of providing a warm or cool airflow as required.
- answer (x)Single-duct single-zone variable air volume

( )Single-duct single-zone constant volume

( )Dual-duct

( )Multizone

Select the answer which best describes this system. Air is supplied to a conditioned
space by a system capable of providing a warm airflow and a cool airflow which is then
mixed by a box at the point of entry to the space. - answer ( )Single-duct zoned variable
air volume

Document information

Uploaded on
August 18, 2025
Number of pages
5
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$16.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Zayla
3.4
(18)
Sold
134
Followers
13
Items
16883
Last sold
2 days ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions