• Wrong document? Swap it for free
  • Written by students who passed
  • Immediately available after payment
  • Read online or as PDF
Sell
Where do you study
Your language
Document preview thumbnail
Preview 4 out of 31 pages
Exam (elaborations)

Mosby's Exam Review Image Production 2025 Questions and Answers

Document preview thumbnail
Preview 4 out of 31 pages

Mosby's Exam Review Image Production 2025 Questions and Answers

Content preview

Mosby's Exam Review Image
Production 2025 Questions and Answers


Which of the following reduces the scatter radiation reaching the detectors? - --

CORRECT ANSWER--both a and c

(Pre-detector collimation and post-patient collimation are synonymous. Both terms

describe a device designed to remove scatter radiation before it reaches the

detector.)

Which of the following is the primary interaction between x-ray photons and tissue

during computed tomography? - --CORRECT ANSWER--Compton effect

(Owing to the high-energy beam used in CT, the Compton effect is the

predominant interaction between x-ray and matter. CT scanners use between 120

and 140 kVp, yielding x-ray energies with averages between 70 and 80 keV.)

The process by which electrons are produced at the cathode of a CT x-ray tube is

known as: - --CORRECT ANSWER--thermionic emission

(When the cathode of an x-ray tube is heated, electrons are released through the

process of thermionic emission. It is these electrons that are then accelerated

toward the anode for x-ray production.)


....COPYRIGHT ©️ 2025 ALL RIGHTS RESERVED...TRUSTED & VERIFIED 1

,The assignment of different generations to CT scanners is based on the

configuration of the: - --CORRECT ANSWER--tube and detectors

(CT scanners are often placed into one of several different "generations." The

differences in generations are based on the relationship of the tube and detectors

and the position of each during data acquisition.)

When one is using a third-generation CT scanner, it is important that reference

detectors positioned at the peripheral portions of the detector array be exposed to:

- --CORRECT ANSWER--unattenuated radiation

(Reference detectors are used to measure incident radiation intensity. This

information is used by the computer during the calculation of the linear

attenuation coefficient. If the patient is placed incorrectly within the gantry, the

reference detectors may be partially blocked, causing an out-of-field artifact.)

In 1979, the scientists __________ and __________ shared the Nobel Prize for

their research in computed tomography. - --CORRECT ANSWER--Hounsfield

and Cormack

(Dr. Godfrey Hounsfield and Dr. Allan Cormack shared the Nobel Prize for their

work on the development of computed tomography in 1979.)

The type of compensating filter used at the x-ray tube of a CT scanner is called a: -

--CORRECT ANSWER--bow-tie filter




....COPYRIGHT ©️ 2025 ALL RIGHTS RESERVED...TRUSTED & VERIFIED 2

,(The bow-tie filter used at the x-ray tube of a CT scanner absorbs a larger amount

of radiation at the periphery of the patient, where the part thickness is reduced.

The center of the patient is placed at the center of the filter, where the largest

amount of radiation is allowed to pass through. The use of this type of filter

attempts to compensate for the differences in thickness of the often oval-shaped

patient.)

The interaction between x-ray and matter that is responsible for the production of

the scatter radiation absorbed by the patient and detectors is: - --CORRECT

ANSWER--Compton effect

(In the Compton interaction, an x-ray photon ejects an outer-shell electron of an

atom. The photon loses some of its energy in the collision and then continues on

in a different, scattered direction. This interaction is the major source of the scatter

radiation involved in the formation of the CT image.)

The types of detectors used in computed tomography are:

1. Gas ionization

2. Stimulable phosphor

3. Scintillation - --CORRECT ANSWER--1 and 3 only

(The types of detectors used in computed tomography are scintillation and gas

ionization detectors. Both operate by measuring the amount of transmitted

radiation passed through the patient and transmitting this information to the


....COPYRIGHT ©️ 2025 ALL RIGHTS RESERVED...TRUSTED & VERIFIED 3

, computer for image reconstruction. Newer MDCT systems utilize solid-state

scintillation detectors exclusively.)

Which of the following is used in gas ionization CT detectors? - --CORRECT

ANSWER--xenon

(Gases with high atomic numbers, such as xenon, are used in ionization-type CT

detector systems. The high atomic number of the xenon gas (Z = 54) increases the

incidence of interaction with x-ray photons, thus improving the efficiency of the

detector.)

Which of the following statements concerning the translate-rotate mode of CT

data acquisition is/are correct?1. 360-degree circular detector arrays are used.2.

Data are collected only during translation.3. Was used in first- and second-

generation CT scanners. - --CORRECT ANSWER--2 and 3 only

(The first- and second-generation CT scanners used a translate-rotate method of

data acquisition. The x-ray tube and detector(s) translated across the patient's head,

recording transmission measurements. The entire system then rotated 1 degree.

This process of translation-rotation then repeated itself for a total of 180 degrees.

First- and second-generation CT scanners used anywhere from 2 to 30 detectors.)

Which of the following terms accurately describes the type of x-ray beam used in a

third-generation CT scanner? - --CORRECT ANSWER--Fan beam




....COPYRIGHT ©️ 2025 ALL RIGHTS RESERVED...TRUSTED & VERIFIED 4

Document information

Uploaded on
August 1, 2025
Number of pages
31
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$12.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
KatelynWhitman
3.6
(260)
Sold
1259
Followers
485
Items
43943
Last sold
23 hours ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions