Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Document preview thumbnail
Preview 4 out of 148 pages
Exam (elaborations)

The best tool for adjusting and setting the pressure on an appliance regulator: a. Manometer b. Velometer c. Psychrometer d. An analyzer - Manometer 3/8 NPS black iron pipe shall? a. Not be used for propane b. Not be used in a concealed location

Document preview thumbnail
Preview 4 out of 148 pages

The best tool for adjusting and setting the pressure on an appliance regulator: a. Manometer b. Velometer c. Psychrometer d. An analyzer - Manometer 3/8 NPS black iron pipe shall? a. Not be used for propane b. Not be used in a concealed location c. Not be used for natural gas d. Not be used for indoors - Not be used in a concealed location (6.3.9) A corrugated metal gas connector connected to a range must not exceed? a. 6' b. 5' c. 3' d. 4' - 6' (6.21.3) A manual shut-off valve shall be installed? a. only on natural gas appliances b. in either drop of riser of a residential appliance c. downstream of the union d. at the drip pocket - In either drop of riser of a residential appliance (6.18.2) Black iron pipe 2 1/2 NPS at 150' long shall be pressure tested to? a. The greater of 50psig or 1.5 times the maximum operation pressure for 180 minutes b. 50 psig for 180 minutes c. 1.5 times the maximum operation pressure for 180 minutes d. 50 psig for 60 minutes - 50 psig for 60 minutes (Table 6.3) Buried piping or tubing shall be? a. only copper type L coated, type G coated, type K uncoated b. only copper type K, L or type G c. schedule 50 ASTM A-53 d. only copper type L or G coated - Only copper type L coated, type G coated, type K uncoated (6.2.7) What is pressure drop? a. The difference in the static pressure at the meter, and the working pressure at the appliance regulator b. The difference between the U tube manometer is the end that is open to the atmosphere and the pressurized side when the appliance regulator is working c. The difference between supply pressure and appliance manifold pressure when the appliance calls for heat d. The difference in the working pressure at the gas meter, and the working pressure at the appliance regulator - The difference in the working pressure at the gas meter, and the working pressure at the appliance regulator Fittings used for steel piping may be made from? a. brass or iron b. copper to malleable iron c. steel and plastic d. malleable iron and steel - Malleable iron and steel (6.2.2) Posts protecting piping and tubing entering a building from vehicular damage shall be? a. clearly marked and identified with yellow paint b. Be spaced not more than 48" apart c. Buried not less than 36" below grade d. Made from 6x6 pressure treated wood - Buried not less than 36" below grade (6.16.15) The equivalent length of a 2 1/2 NPS forged tee is?

Content preview

G2 Exam Prep Verified And Complete
Questions and Answers Graded A+



The best tool for adjusting and setting the pressure on an appliance regulator:



a.

Manometer



b.

Velometer



c.

Psychrometer



d.

An analyzer - Manometer



3/8 NPS black iron pipe shall?



a. Not be used for propane

b. Not be used in a concealed location

c. Not be used for natural gas

d. Not be used for indoors - Not be used in a concealed location (6.3.9)



A corrugated metal gas connector connected to a range must not exceed?

,a. 6'

b. 5'

c. 3'

d. 4' - 6' (6.21.3)



A manual shut-off valve shall be installed?



a. only on natural gas appliances

b. in either drop of riser of a residential appliance

c. downstream of the union

d. at the drip pocket - In either drop of riser of a residential appliance (6.18.2)



Black iron pipe 2 1/2 NPS at 150' long shall be pressure tested to?



a. The greater of 50psig or 1.5 times the maximum operation pressure for 180 minutes

b. 50 psig for 180 minutes

c. 1.5 times the maximum operation pressure for 180 minutes

d. 50 psig for 60 minutes - 50 psig for 60 minutes (Table 6.3)



Buried piping or tubing shall be?



a. only copper type L coated, type G coated, type K uncoated

b. only copper type K, L or type G

c. schedule 50 ASTM A-53

d. only copper type L or G coated - Only copper type L coated, type G coated, type K
uncoated (6.2.7)

,What is pressure drop?



a. The difference in the static pressure at the meter, and the working pressure at the
appliance regulator

b. The difference between the U tube manometer is the end that is open to the atmosphere
and the pressurized side when the appliance regulator is working

c. The difference between supply pressure and appliance manifold pressure when the
appliance calls for heat

d. The difference in the working pressure at the gas meter, and the working pressure at the
appliance regulator - The difference in the working pressure at the gas meter, and the
working pressure at the appliance regulator



Fittings used for steel piping may be made from?



a. brass or iron

b. copper to malleable iron

c. steel and plastic

d. malleable iron and steel - Malleable iron and steel (6.2.2)



Posts protecting piping and tubing entering a building from vehicular damage shall be?



a. clearly marked and identified with yellow paint

b. Be spaced not more than 48" apart

c. Buried not less than 36" below grade

d. Made from 6x6 pressure treated wood - Buried not less than 36" below grade

(6.16.15)



The equivalent length of a 2 1/2 NPS forged tee is?

, a. 9.25'

b. 12.4'

c. 15.3'

d. 10.3' - 9.25' (Table A 16)



What is the maximum horizontal spacing of supports for N.P.S. 1 1/4 inch gas pipe?



a. 8'

b. 15'

c. 6'

d. 10' - 10' (3m) (Table 6.2)



When gas piping enters a building, it must?



a. Enter above grade

b. Be taped, painted, and sleeved

c. Have a tracer wire

d. Enter below grade - Enter above grade (6.15.8)



When sizing a branch line, what is the minimum size of job fabricated welding fittings that
can be used on a NPS 6 gas supply header?



a. 2" NPS

b. 3/4" NPS

c. 3" NPS

d. 1/2" NPS - 3/4" NPS (6.8.8)



A dirt pockets shall be installed at the bottom of any piping or tubing, on the final drop
serving an appliance other than a(n)

Document information

Uploaded on
August 1, 2025
Number of pages
148
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$11.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Examset
4.0
(1)
Sold
4
Followers
2
Items
458
Last sold
9 months ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions