What must you have signed by the customer before entering into a contract on a
property that is currently under an active wdo warranty? - (ANSWER)Form 13671
(consumer consent form)
The eastern sub termite belongs to what family? - (ANSWER)Rhinotermitidae
Drywood and dampwood termites belong to the family? -
(ANSWER)Kalotemritidae
according to the revised taxonomy of termites, these insects belong in the order
____ along with cockroaches - (ANSWER)Blattodae
the Old House Borer is a example of? - (ANSWER)Longhorned wood borer
which is required to be reported on the Form 13645? - (ANSWER)Evidence,
Damage and live organisms
When must you use a form 13645 inspection report? - (ANSWER)For real estate
transactions,
and for real estate transactions when a written report is requested
,which is the minimum amount of errors on omissions liability insurance? -
(ANSWER)$500,000/$250,00
which are the two documents that can give you guidance on completing a form
13645 inspection report? - (ANSWER)The industry baseline practices and the
guidelines for the use and completion of the form 13645
Under the definition as they pertain to wdo inspections, live or living would
include all of the following EXCEPT? - (ANSWER)powerpost beetle frass streaming
out of holes
under the definitions as they pertain to wdo inspections, structures would include
all of the following but not? - (ANSWER)detached private fences
you would report damage and deterioration to particle board and masonry siding
caused by exposure to water and sunlight, including the delamination water
stains, peeling, separation and other break down cellulose materials on a form
13645 inspection report - (ANSWER)false
which of these items could be stated as areas excluded from an exterior of a
structure from the form 13645 inspection report? - (ANSWER)stored items and
debris stacked against the structure
which of the following is not an example of a conducive condition that may lead
to the presence of wood destroying organisms? - (ANSWER)wood roof shingles
, which would not be a valid reason for excluding the inspection of the entire attic
of a structure? - (ANSWER)insulation covers trust trails
conducive conditions for termite or wood decaying fungi infestations would
include all of the following but not? - (ANSWER)oak trees located on the property
if you do not properly check any boxes in Section 3 (obstructions and inaccessible
areas) on form 13645, then you have indicated that? - (ANSWER)the area was
inspected and considered accessible
as part of the wdo inspection, evidence of a wood destroying organism would not
include? - (ANSWER)Ambrosia Beetle stains
the purpose of the wdo inspection report is to communicate information about
the presence or absence of wood destroying organisms at the time of the
inspection, therefore, it is considered to be warrantied for? - (ANSWER)none of
the above
according to the industry Baseline practices, what is the minimum opening size
for an attic entrance? - (ANSWER)20" x 20"
according to the industry Baseline practices what is the minimum opening size
through the truss webbing in the Attic? - (ANSWER)22" x 48"
COMPLETE QUESTIONS With 100% Verified Solutions,
What must you have signed by the customer before entering into a contract on a
property that is currently under an active wdo warranty? - (ANSWER)Form 13671
(consumer consent form)
The eastern sub termite belongs to what family? - (ANSWER)Rhinotermitidae
Drywood and dampwood termites belong to the family? -
(ANSWER)Kalotemritidae
according to the revised taxonomy of termites, these insects belong in the order
____ along with cockroaches - (ANSWER)Blattodae
the Old House Borer is a example of? - (ANSWER)Longhorned wood borer
which is required to be reported on the Form 13645? - (ANSWER)Evidence,
Damage and live organisms
When must you use a form 13645 inspection report? - (ANSWER)For real estate
transactions,
and for real estate transactions when a written report is requested
,which is the minimum amount of errors on omissions liability insurance? -
(ANSWER)$500,000/$250,00
which are the two documents that can give you guidance on completing a form
13645 inspection report? - (ANSWER)The industry baseline practices and the
guidelines for the use and completion of the form 13645
Under the definition as they pertain to wdo inspections, live or living would
include all of the following EXCEPT? - (ANSWER)powerpost beetle frass streaming
out of holes
under the definitions as they pertain to wdo inspections, structures would include
all of the following but not? - (ANSWER)detached private fences
you would report damage and deterioration to particle board and masonry siding
caused by exposure to water and sunlight, including the delamination water
stains, peeling, separation and other break down cellulose materials on a form
13645 inspection report - (ANSWER)false
which of these items could be stated as areas excluded from an exterior of a
structure from the form 13645 inspection report? - (ANSWER)stored items and
debris stacked against the structure
which of the following is not an example of a conducive condition that may lead
to the presence of wood destroying organisms? - (ANSWER)wood roof shingles
, which would not be a valid reason for excluding the inspection of the entire attic
of a structure? - (ANSWER)insulation covers trust trails
conducive conditions for termite or wood decaying fungi infestations would
include all of the following but not? - (ANSWER)oak trees located on the property
if you do not properly check any boxes in Section 3 (obstructions and inaccessible
areas) on form 13645, then you have indicated that? - (ANSWER)the area was
inspected and considered accessible
as part of the wdo inspection, evidence of a wood destroying organism would not
include? - (ANSWER)Ambrosia Beetle stains
the purpose of the wdo inspection report is to communicate information about
the presence or absence of wood destroying organisms at the time of the
inspection, therefore, it is considered to be warrantied for? - (ANSWER)none of
the above
according to the industry Baseline practices, what is the minimum opening size
for an attic entrance? - (ANSWER)20" x 20"
according to the industry Baseline practices what is the minimum opening size
through the truss webbing in the Attic? - (ANSWER)22" x 48"