MRI registry (MRI safety) EXAMVERIFIED | LATEST UPDATE A+ PASS ACR recommended Zone 1 signage designates an area intended for _________________. A. Screened MRI patients/personnel B. General public C. Screened MRI patients under constant direct supervision of trained MR personnel D. Unscreened MRI patients - Answer- B. General public The intensity limit for a static magnetic field by the FDA for the entire population is? A. 5 Gauss B. 1.0Tesla C. 3.0 Tesla D. 4.0 Tesla E. 8.0 Tesla - Answer- D. 4.0 Tesla The intensity limit for a static magnetic field in clinical use is limited by the Food and Drug Administration (FDA) to 4.0 tesla (T)field strength for the entire population.(Clinical imaging in patients over one month of age and above limited to 8Tesla) ACR recommended Zone 4 signage designates an area intended for: A. Screened MRI patients/personnel B. General public C. Screened MRI patients under constant direct supervision of trained MR personnel D. Unscreened MRI patients - Answer- C. Screened MRI patients under constant direct supervision of trained MR personnel The fringe magnetic field: A. Is eliminated by magnetic shielding B. Is eliminated by shimming C. Poses no safety risks if proper shielding is utilized D. Can cause nearby medical devices to malfunction - Answer- D. Can cause nearby medical devices to malfunction What type of pulse sequence transmits the most RF to the patient and consequently can potentially have more SAR restrictions? A. Gradient echo B. Fast spin echo C. Inversion recovery D. Spin echo - Answer- B. Fast spin echo Fast spin echo sequences utilize ETL (echo train lengths/180° RF pulses) to reduce scan time, at the expense of increased RF power/absorption to the patient Which of the following is regulated by the FDA? A. Billable amounts per procedure B. Aperture of the magnet construction C. Resolution maximums D. Acoustic noise - Answer- D. Acoustic noise FDA safety levels for RF exposure during MR examination are defined by SAR restrictions, which are imposed to reduce the risk of: A. Panic attacks or anxiety during the MR procedure B. Induction of current within the surface receiver coils C. Systemic and/or thermal injury to patient D. Gradient induced acoustic noise overexposure - Answer- C. Systemic and/or thermal injury to patient ACR recommended Zone 2 signage designates an area intended for: A. Screened MRI patients/personnel B. General public C. Screened MRI patients under constant direct supervision of trained MR personnel D. Unscreened MRI patients - Answer- D. Unscreened MRI patients The FDA recommends posting warning signs to indicate the _________ line. A. Mendoza B. 5 Gauss C. 3 Tesla D. 0.5 Gauss - Answer- B. 5 Gauss FDA guidelines dictate a level of concern when RF energy absorption produces an increase in body temperature of: A. 0.1° Fahrenheit B. 1° Fahrenheit C. 0.1° Celsius D. 1° Celsius - Answer- D. 1° Celsius ACR recommended Zone 3 signage designates an area intended for: A. Screened MRI patients/personnel B. General public C. Screened MRI patients under constant direct supervision of trained MR personnel D. Unscreened MRI patients - Answer- A. Screened MRI patients/personnel The magnetic field that the MR technologist is most exposed to would be the: A. Static magnetic field B. Radiofrequency field C. Time varying magnetic field D. Shim Coil - Answer- A. Static magnetic field Risk factors of MR exposure with regards to SAR include all of the following EXCEPT: A. Cardiovascular disease B. Hypotension C. Obesity D. Geriatric patients - Answer- B. Hypotension The intensity limit for a static magnetic field in clinical use is limited by the FDA to what field strength? (Clinical imaging in patients over one month of age and above) A. 5 Gauss B. 1.0Tesla C. 3.0 Tesla D. 4.0 Tesla E. 8.0 Tesla - Answer- E. 8.0 Tesla

Content preview

MRI registry (MRI safety)
EXAMVERIFIED | LATEST UPDATE A+
PASS
ACR recommended Zone 1 signage designates an area intended for
_________________.
A. Screened MRI patients/personnel
B. General public
C. Screened MRI patients under constant direct supervision of trained MR personnel
D. Unscreened MRI patients - Answer- B. General public

The intensity limit for a static magnetic field by the FDA for the entire population is?
A. 5 Gauss
B. 1.0Tesla
C. 3.0 Tesla
D. 4.0 Tesla
E. 8.0 Tesla - Answer- D. 4.0 Tesla

The intensity limit for a static magnetic field in clinical use is limited by the Food and
Drug Administration (FDA) to 4.0 tesla (T)field strength for the entire population.(Clinical
imaging in patients over one month of age and above limited to 8Tesla)

ACR recommended Zone 4 signage designates an area intended for:
A. Screened MRI patients/personnel
B. General public
C. Screened MRI patients under constant direct supervision of trained MR personnel
D. Unscreened MRI patients - Answer- C. Screened MRI patients under constant direct
supervision of trained MR personnel

The fringe magnetic field:
A. Is eliminated by magnetic shielding
B. Is eliminated by shimming
C. Poses no safety risks if proper shielding is utilized
D. Can cause nearby medical devices to malfunction - Answer- D. Can cause nearby
medical devices to malfunction

What type of pulse sequence transmits the most RF to the patient and consequently
can potentially have more SAR restrictions?
A. Gradient echo
B. Fast spin echo
C. Inversion recovery
D. Spin echo - Answer- B. Fast spin echo

, Fast spin echo sequences utilize ETL (echo train lengths/180° RF pulses) to reduce
scan time, at the expense of increased RF power/absorption to the patient

Which of the following is regulated by the FDA?
A. Billable amounts per procedure
B. Aperture of the magnet construction
C. Resolution maximums
D. Acoustic noise - Answer- D. Acoustic noise

FDA safety levels for RF exposure during MR examination are defined by SAR
restrictions, which are imposed to reduce the risk of:
A. Panic attacks or anxiety during the MR procedure
B. Induction of current within the surface receiver coils
C. Systemic and/or thermal injury to patient
D. Gradient induced acoustic noise overexposure - Answer- C. Systemic and/or
thermal injury to patient

ACR recommended Zone 2 signage designates an area intended for:
A. Screened MRI patients/personnel
B. General public
C. Screened MRI patients under constant direct supervision of trained MR personnel
D. Unscreened MRI patients - Answer- D. Unscreened MRI patients

The FDA recommends posting warning signs to indicate the _________ line.
A. Mendoza
B. 5 Gauss
C. 3 Tesla
D. 0.5 Gauss - Answer- B. 5 Gauss

FDA guidelines dictate a level of concern when RF energy absorption produces an
increase in body temperature of:
A. 0.1° Fahrenheit
B. 1° Fahrenheit
C. 0.1° Celsius
D. 1° Celsius - Answer- D. 1° Celsius

ACR recommended Zone 3 signage designates an area intended for:
A. Screened MRI patients/personnel
B. General public
C. Screened MRI patients under constant direct supervision of trained MR personnel
D. Unscreened MRI patients - Answer- A. Screened MRI patients/personnel

The magnetic field that the MR technologist is most exposed to would be the:
A. Static magnetic field
B. Radiofrequency field
C. Time varying magnetic field

Document information

Uploaded on
July 26, 2025
Number of pages
7
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$12.44

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
ScholarExams
3.8
(73)
Sold
396
Followers
186
Items
11539
Last sold
1 hour ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions