Based on ANSI/ASHRAE/IESNA Standard 90.1, Energy Standard for Building Except Low-Rise Residential Buildings, which method is the MOST direct and easiest to use to determine the maximum allowable lighting power density (LPD)? (A) space-by-space method (B) lighting system method (C) building area method (D) energy cost budget method - ANS (C) building area method To confirm that a particular project meets material flammability requirements, and interior designer should (A) contact each manufacturer whose materials are used B) refer to state flammability regulations (C) contact the authority having jurisdiction (AHJ) (D) review the International Building Code (IBC) - ANS (C) contact the authority having jurisdiction (AHJ) An interior designer has just finished reviewing the plans for a large office suite when the building department states that the lighting budget has been NCIDQ PRACTICE TESTS EXAM 2025 QUESTIONS AND ANSWERS 2 Copyright ©2025 SIRJOEL ALL RIGHTS RESERVED exceeded. If the design is composed of 80% fluorescent lighting and 20% incandescent lighting, what is the BEST course of action to begin redesign (A) Reduce the number of luminaires by spacing them (B) Substitute all incandescent lights (C) Change to a task-ambient lighting system. (D) Investigate whether lamps with higher efficacies will br - ANS (D) Investigate whether lamps with higher efficacies will bring the design within the budget. What are the MOST important design elements to incorporate into a hotel to provide safe egress for people with physical disabilities? (A) visual alarms and audible alarms (B) visual alarms and flashing smoke detectors (C) audible alarms and large emergency lettering (D) audible alarms and tactile signage - ANS (A) visual alarms and audible alarms When a project includes both fixed partition walls and a full-height movable partition system, on what plan should the movable partition system be shown? (A) a separate moveable partition plan (B) the construction floor plan (C) the furniture plan (D) both the floor and furniture plans - ANS (B) the construction floor plan The method of constructing a fire-rated partition is typically indicated in the 3 Copyright ©2025 SIRJOEL ALL RIGHTS RESERVED (A) partition details (B) floor plan keynotes (C) partition schedule (D) contract specifications - ANS (A) partition details Sharing common information in the same CAD file to create different types of drawings is known as (A) building modeling (B) using the drawing modules standard (C) layering of drawings (D) using the U.S. National CAD Standard (NCS) - ANS (C) layering of drawings Changing a ceiling from gypsum wallboard to acoustic tile would MOST affect the room's (A) reverberation time (B) sound transmission (C) decibel loss (D) impact insulation class - ANS (A) reverberation time Which of the following are effective strategies for controlling moisture when detailing the area around a spa pool? (Choose the four that apply.) (A) adhesives (B) drainage (C) slip resist

Content preview

NCIDQ PRACTICE TESTS EXAM 2025
QUESTIONS AND ANSWERS


Based on ANSI/ASHRAE/IESNA Standard 90.1, Energy Standard for
Building Except Low-Rise Residential Buildings, which method is the MOST
direct and easiest to use to determine the maximum allowable lighting power
density (LPD)?


(A) space-by-space method
(B) lighting system method
(C) building area method

(D) energy cost budget method - ANS (C) building area method


To confirm that a particular project meets material flammability requirements,
and interior designer should


(A) contact each manufacturer whose materials are used
B) refer to state flammability regulations
(C) contact the authority having jurisdiction (AHJ)

(D) review the International Building Code (IBC) - ANS (C) contact the authority having
jurisdiction (AHJ)


An interior designer has just finished reviewing the plans for a large office
suite when the building department states that the lighting budget has been

1 Copyright ©2025 SIRJOEL ALL RIGHTS RESERVED

,exceeded. If the design is composed of 80% fluorescent lighting and 20%
incandescent lighting, what is the BEST course of action to begin redesign


(A) Reduce the number of luminaires by spacing them
(B) Substitute all incandescent lights
(C) Change to a task-ambient lighting system.

(D) Investigate whether lamps with higher efficacies will br - ANS (D) Investigate whether
lamps with higher efficacies will bring the design within the budget.


What are the MOST important design elements to incorporate into a hotel to
provide safe egress for people with physical disabilities?


(A) visual alarms and audible alarms
(B) visual alarms and flashing smoke detectors
(C) audible alarms and large emergency lettering

(D) audible alarms and tactile signage - ANS (A) visual alarms and audible alarms


When a project includes both fixed partition walls and a full-height movable
partition system, on what plan should the movable partition system be
shown?


(A) a separate moveable partition plan
(B) the construction floor plan
(C) the furniture plan

(D) both the floor and furniture plans - ANS (B) the construction floor plan


The method of constructing a fire-rated partition is typically indicated in the

2 Copyright ©2025 SIRJOEL ALL RIGHTS RESERVED

,(A) partition details
(B) floor plan keynotes
(C) partition schedule

(D) contract specifications - ANS (A) partition details


Sharing common information in the same CAD file to create different types
of drawings is known as


(A) building modeling
(B) using the drawing modules standard
(C) layering of drawings

(D) using the U.S. National CAD Standard (NCS) - ANS (C) layering of drawings


Changing a ceiling from gypsum wallboard to acoustic tile would MOST
affect the room's


(A) reverberation time
(B) sound transmission
(C) decibel loss

(D) impact insulation class - ANS (A) reverberation time


Which of the following are effective strategies for controlling moisture when
detailing the area around a spa pool? (Choose the four that apply.)


(A) adhesives
(B) drainage
(C) slip resistance

3 Copyright ©2025 SIRJOEL ALL RIGHTS RESERVED

, (D) flashing
(E) tile selection
(F) sealants(B) drainage
(D) flashing
(E) tile selection

(F) sealants - ANS (B) drainage
(D) flashing
(E) tile selection
(F) sealants


In working with an electrical engineer on a project, what information would
the designer MOST likely put on the interior designer power plan?


(A) switch locations
(B) dedicated outlets
(C) conduit sizing

(D) speaker locations - ANS (B) dedicated outlets


What is one feature of inclusive design that differentiates it from accessibility
and universal design?


(A) conforms to ADA requirements
(B) considers cultural and social needs
(C) does not include a broad range of diversity

(D) responds to a broad range of users - ANS (B) considers cultural and social needs


Which furniture test requires that an actual piece of furniture, or an accurate

4 Copyright ©2025 SIRJOEL ALL RIGHTS RESERVED

Document information

Uploaded on
July 26, 2025
Number of pages
33
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$13.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
sirjoel
3.6
(18)
Sold
133
Followers
13
Items
12780
Last sold
2 months ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions