2015 INTERNATIONAL FUEL GAS CODE EXAM NEWEST 2025 ACTUAL EXAM QUESTIONS AND CORRECT DETAILED ANSWERS (VERIFIED ANSWERS) |ALREADY GRADED A+ A valve designed to activate when fuel gas passing through it exceeds a prescribed flow rate is a . - CORRECT ANSA. Excess flow valve An appliance that operates with a non-positive vent static pressure and with a vent gas temperature that is capable of causing excessive condensate production in the vent is a appliance. - CORRECT ANSB. Category II Holes bored in a floor joist shall not exceed their depth. - CORRECT ANSC. 1/3 Bored holes shall no be greater than of the stud depth in non-load bearing walls where each bored stud is doubled. - CORRECT ANSB. 60% Gas appliances shall not be located in a unless it meets one of the approved exceptions. - CORRECT ANSC. Bathroom A single wall mounted unvented natural gas room heater equipped with an oxygen depletion safety system may be installed in a . - CORRECT ANSA. bathroom if it is 6,000 btu's or less Indoor combustion air for gas appliances using the standard method is sized based on cubic feet per 1,000 btu/h of the appliance input rating. - CORRECT ANSA. 50 How many cubic feet of space would be required to use the standard method of combustion air for gas appliances if you had a space with a 60,000 btu fan assisted furnace, 34,000 btu natural draft water heater, and 28,000 btu gas dryer? - CORRECT ANSC. 6,100 cu ft 2 What would the maximum gas appliance btu input be for an open basement measuring 26'x52' with an 8' ceiling to be able to use the standard combustion air method? - CORRECT ANSA. 216,320 When combing spaces on the same story to obtain the required combustion air for gas appliances, each opening shall be sized a minimum 1 sq. in for the total input rating of all gas appliances but not less than sq. in. - CORRECT ANSD. 100 The minimum dimension of air openings for combustion air for gas appliances is - CORRECT ANSA. 3" When using two permanent openings to provide combustion air for gas appliances and communicating directly with the outdoors, each opening shall have a minimum free area of 1 sq. in for every total input rating of all equipment in the enclosure. - CORRECT ANSB. 4,000 btu When installing all gas appliances, combustion air is allowed to utilize one permanent opening commencing within 12" from the top of the enclosure. The opening must be a minimum 1 sq. in for every total appliance input. - CORRECT ANSB. 3,000 btu

Content preview

1


2015 INTERNATIONAL FUEL GAS CODE EXAM
NEWEST 2025 ACTUAL EXAM QUESTIONS AND
CORRECT DETAILED ANSWERS (VERIFIED
ANSWERS) |ALREADY GRADED A+
A valve designed to activate when fuel gas passing through it exceeds a prescribed flow rate
is a .
- CORRECT ANS>>A. Excess flow valve


An appliance that operates with a non-positive vent static pressure and with a vent gas
temperature that is capable of causing excessive condensate production in the vent is a
appliance.
- CORRECT ANS>>B. Category II


Holes bored in a floor joist shall not exceed their depth.
- CORRECT ANS>>C. 1/3


Bored holes shall no be greater than of the stud depth in non-load bearing walls where
each bored stud is doubled.
- CORRECT ANS>>B. 60%


Gas appliances shall not be located in a unless it meets one of the approved exceptions.
- CORRECT ANS>>C. Bathroom


A single wall mounted unvented natural gas room heater equipped with an oxygen depletion
safety system may be installed in a .
- CORRECT ANS>>A. bathroom if it is 6,000 btu's or less


Indoor combustion air for gas appliances using the standard method is sized based on cubic
feet per 1,000 btu/h of the appliance input rating.
- CORRECT ANS>>A. 50


How many cubic feet of space would be required to use the standard method of combustion
air for gas appliances if you had a space with a 60,000 btu fan assisted furnace, 34,000 btu
natural draft water heater, and 28,000 btu gas dryer?
- CORRECT ANS>>C. 6,100 cu ft

, 2

What would the maximum gas appliance btu input be for an open basement measuring
26'x52' with an 8' ceiling to be able to use the standard combustion air method?
- CORRECT ANS>>A. 216,320


When combing spaces on the same story to obtain the required combustion air for gas
appliances, each opening shall be sized a minimum 1 sq. in for the total input rating of all gas
appliances but not less than sq. in.
- CORRECT ANS>>D. 100

The minimum dimension of air openings for combustion air for gas appliances is
- CORRECT ANS>>A. 3"


When using two permanent openings to provide combustion air for gas appliances and
communicating directly with the outdoors, each opening shall have a minimum free area of 1
sq. in for every total input rating of all equipment in the enclosure.
- CORRECT ANS>>B. 4,000 btu


When installing all gas appliances, combustion air is allowed to utilize one permanent
opening commencing within 12" from the top of the enclosure. The opening must be a
minimum 1 sq. in for every total appliance input.
- CORRECT ANS>>B. 3,000 btu


When mechanical combustion air is provided for gas appliances, the combustion air shall be
supplied from the outdoors at a rate not less than cfm per 1,000 btu/h of total input rating of
all appliances located within the space.
- CORRECT ANS>>C. .35


Where exhaust fans are installed, air shall be provided to replace the exhausted air.
- CORRECT ANS>>D. make up


Where the design free area of louvers and grilles are not known, it shall be assumed that
wood louvers will have % free area and metal louvers will have % free area.
- CORRECT ANS>>D. 25; 75


Combustion air ducts for gas appliances shall not be where terminating in an attic.
- CORRECT ANS>>A. screened


Condensate waste and drain line size shall not be less then .
- CORRECT ANS>>D. 3/4" internal diameter

Document information

Uploaded on
July 16, 2025
Number of pages
7
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$13.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Nurslink
3.5
(27)
Sold
237
Followers
72
Items
1693
Last sold
2 weeks ago


Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions