How much extra refrigerant con be stored in a machine room?
A) 330 lbs.
B) The amount equal to the design pressure.
C) 20% above normal charge.
D) 220 lbs. - Correct Answer - C) 20% above normal charge.


A refrigeration compressor has failed to turn on. The refrigeration
engineer on duty verifies that the electrical circuit to the motor,
including all switches and circuit breakers, is complete according to
recommended service practice. The next item to be checked would likely
by the
A) temperature and pressure controls.
B) refrigerant charge.
C) cooling tower operation.
D) liquid-line solenoid valve. - Correct Answer - A) temperature and
pressure controls.


The use of oil in the refrigeration machine is to
A) Add non-condensates to refrigerant.
B) Mix the oil with liquid refrigerant.

pg. 1

,C) Reduce wear and friction in compressor parts.
D) None of the answers are correct. - Correct Answer - C) Reduce wear
and friction in compressor parts.


The heat removed from the refrigerant condenser is
A) latent heat only.
B) sensible heat only.
C) sensible and latent heat.
D) Radiant heat only. - Correct Answer - C) sensible and latent heat.


Which service valve should be installed in a dual pressure release valve
while keeping system in service?
A) Two-way valve.
B) Plug valve.
C) Three-way valve.
D) Stop valve. - Correct Answer - C) Three-way valve.


The monthly quick check of a fire extinguisher does NOT include
A) Checking the extinguisher for damage.
B) Confirming its proper location.
C) Discharging the extinguisher.
D) Ensuring it is clear from any obstructions. - Correct Answer - C)
Discharging the extinguisher.



pg. 2

,Several components of a sprinkler system in an office building need to
be repaired. Which of the following are allowed to perform the repair
work?
A) A Q-01 refrigeration engineer holding S-12 CoF.
B) A Master Fire Suppression Contractor holding S-12 CoF.
C) Any Master Fire Suppression Piping Contractor.
D) A S-12 CoF holder without any other license. - Correct Answer - B) A
Master Fire Suppression Contractor holding S-12 CoF.


A FDNY permit is required to conduct hot work for
A) brazing.
B) welding.
C) use of oxygen and flammable gas.
D) All answers are correct - Correct Answer - D) All answers are correct


Which of the following correctly describes the object in the picture
below?
A) Carbon dioxide system nozzle, to extinguish electrical fires.
B) Cooling tower makeup valve, to put out fires in case of emergency.
C) Standpipe hose outlet, to put out fires in case of emergency.
D) Water chemistry supply station, for condenser water. - Correct
Answer - C) Standpipe hose outlet, to put out fires in case of emergency.




pg. 3

, While on duty, a refrigerant engineer notices that the suction line to the
compressor and part of the compressor is frosted. Of the following, the
most likely reason for this condition is
A) the TEV is almost closed.
B) overcharge.
C) there is a blockage in the liquid line
D) low condenser water temperature. - Correct Answer - B) overcharge.


You find that the check valve on a centrifugal pump is leaking. When
will the most damage be caused to the pump?
A) When another pump is turned on.
B) On shutdown.
C) When servicing the pump.
D) On startup. - Correct Answer - D) On startup.


What is the lowest temperature the water in the cooling tower can be?
A) Ambient.
B) Between wet and dry bulb.
C) Dry bulb.
D) Wet bulb. - Correct Answer - B) Between wet and dry bulb.


The most important reason to subcool the refrigerant in the condenser is
to ensure that
A) liquid slugs will not enter the compressor.


pg. 4

Document information

Uploaded on
July 3, 2025
Number of pages
49
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$19.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
ASSIGNMENT7
3.9
(173)
Sold
939
Followers
29
Items
3841
Last sold
3 days ago


Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions