Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4,6 TrustPilot
logo-home
Document preview thumbnail
Preview 2 out of 5 pages
Exam (elaborations)

Oil burner test || A+ GRADED!!!

Document preview thumbnail
Preview 2 out of 5 pages

A fuel oil storage tank cannot be installed: correct answers In the furnace room 5 feet within heating unit What temperature does a thermal wheel automatically activate at correct answers 165°F Who inspects an oil burner installation correct answers State fire marshal Any valve used on a oil burner install must be: correct answers Fusible valve What form is used to pull an oil burner permit correct answers CMR.4 What size pipe is used to CrossConnect tank outlet piping correct answers 1/2 inch When is an oil safety valve used correct answers On an existing installation when a burner boiler furnace or tank is replaced. When must you install a draft regulator correct answers When not exempt by manufacturer What type of boiler must be equipped with a low water cut off correct answers Water boilers over 500,000 BTUs & all steam boilers All new oil burner controls must be: correct answers Interrupted ignition How far must continuous concrete slab extend beyond the tank perimeter correct answers 8 inches All protective control and emergency devices shall be series connected from the electrical distribution panel: correct answers Through the emergency switch, through the terminal switch, to the service switch in the ungrounded line conductor If the ceiling above the burner boiler or burner furnace exceeds 12 feet in height, and additional thermal switch shall be installed at a height of_______ and connected in series with the lower switch. correct answers 10 feet An oil safety valve can perform the following functions: correct answers Reduce pressure from its inlet to its outlet & prevent gravity flow Fuel oil filters should be selected for the following: correct answers Micron range & flow rate Ultra low sulfur fuel has no benefit to a fuel oil system correct answers False To ensure the best mechanical seal throughout a fuel oil delivery system the following should be used: correct answers Flared fittings and pipe dope Adding a pre-heater to an oil burner will correct answers Allow oil with a high paraffin base to flow more easily & decrease the viscosity of a fuel oil A probe type low-water cut off for steam should be checked correct answers Once a year

Content preview

Oil burner test || A+ GRADED!!!
A fuel oil storage tank cannot be installed: correct answers In the furnace room 5 feet within
heating unit

What temperature does a thermal wheel automatically activate at correct answers 165°F

Who inspects an oil burner installation correct answers State fire marshal

Any valve used on a oil burner install must be: correct answers Fusible valve

What form is used to pull an oil burner permit correct answers CMR.4

What size pipe is used to CrossConnect tank outlet piping correct answers 1/2 inch

When is an oil safety valve used correct answers On an existing installation when a burner
boiler furnace or tank is replaced.

When must you install a draft regulator correct answers When not exempt by manufacturer

What type of boiler must be equipped with a low water cut off correct answers Water boilers
over 500,000 BTUs & all steam boilers

All new oil burner controls must be: correct answers Interrupted ignition

How far must continuous concrete slab extend beyond the tank perimeter correct answers 8
inches

All protective control and emergency devices shall be series connected from the electrical
distribution panel: correct answers Through the emergency switch, through the terminal
switch, to the service switch in the ungrounded line conductor

If the ceiling above the burner boiler or burner furnace exceeds 12 feet in height, and
additional thermal switch shall be installed at a height of_______ and connected in series
with the lower switch. correct answers 10 feet

An oil safety valve can perform the following functions: correct answers Reduce pressure
from its inlet to its outlet & prevent gravity flow

Fuel oil filters should be selected for the following: correct answers Micron range & flow rate

Ultra low sulfur fuel has no benefit to a fuel oil system correct answers False

To ensure the best mechanical seal throughout a fuel oil delivery system the following should
be used: correct answers Flared fittings and pipe dope

Adding a pre-heater to an oil burner will correct answers Allow oil with a high paraffin base
to flow more easily & decrease the viscosity of a fuel oil

A probe type low-water cut off for steam should be checked correct answers Once a year

, The proper value for a resistor used to verify the F-F terminals of a Honeywell primary
control should be correct answers 1500 ohms

Oil tanks can be produced as correct answers Steel, fiberglass, epoxy coated steel

Black colored residue on a combustion head tells you correct answers All the above

A white material in the flue pipe resembling beach sand is an indicator of correct answers
Unit that is under fired

Flame quality has no effect on the cad cell correct answers False

A material that will easily allow electrons to pass is described as correct answers Conductor

The safety ground is required by UL to be colored correct answers Green

A solenoid valve operates on the following principle correct answers Electromagnetism

What type of meter requires a battery correct answers Ohmmeter

The purpose of a limit control is correct answers Safety

Switching relays for heating systems can be found in the following switching configurations
correct answers SP-ST, DP-ST, DP-DT. All the above

Fuel oil contains approximately the following percentages of chemicals correct answers 79%
nitrogen and 21% oxygen

Mechanical draft is described as correct answers Forced draft

As stack temperature goes down the ability of a chimney to produce thermal draft drops
correct answers True

Oil burners can make CO even when no smoke is present correct answers True

The best way to detect CO is correct answers Test for it

A yellow spot on test paper may indicate CO correct answers True

Adequate breaching draft will always reduce the risk of CO in a structure correct answers
True

The oil line should always be flushed from the tank all the way through the nozzle correct
answers True

The safety switch of a primary should be checked by: correct answers Closing a oil valve,
pulling a cad cell lead, disconnecting the motor lead.
All the above

Document information

Uploaded on
July 2, 2025
Number of pages
5
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$12.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
ProPerfomer
3.8
(84)
Sold
443
Followers
322
Items
8859
Last sold
3 weeks ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their exams and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can immediately select a different document that better matches what you need.

Pay how you prefer, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card or EFT and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions