It has a high water content that absorbs a great deal of
Why is gypsum unique?
heat as the moisture evaporates
Interior laugh and plaster Very dificult
walls can be ____
_ _ to penetrate with axes or
hand tools
_ _ is typically used for Fiberglass
insulation
Most plastic will and Melt
contribute to the
fuel load
Why are composite or Because they are cost effective and fairly easy to manufacture
engineered
materials frequently used to
substitute for wood or
steel framing found in
older
buildings?
The structural failure of a Structural collapse
building or any portion of
it, resulting from a fire,
snow, wind, water, or
damage from other forces,
is referred to as __________
Church steeples, water Collapse hazard
tanks, chimneys, and false
facades that extend above
the structure must be
viewed as a potential
_ ______ even if the structure
1/66
,6/29/25, 5:07 PM TCFP FF2
is not
Type I construction high-rise Flying glass from windows
buildings are not likely to
collapse, making the
primary concern the hazard of
_______ _______ ______ ______ or
curtain walls
If Type I structural collapse Localized
does occur, it will be
_______ and not
structure wide
When exposed the 1000 degrees
temperatures above
_ _ , and protect still will
expand and
twist, pushing out walls, and
when cool, will slightly
constrict
Masonry construction can One piece or crumble
collapse in ___
_____ or _____
When masonry construction The collapse of other structures or objects
collapses, the debris can
travel some distance and
cause what?
Walls in type V construction Inward or outward
may collapse
________ or _________
You should plan for a Type V
collapse zone at any fire
incident with what type of
building construction?
2/66
,6/29/25, 5:07 PM TCFP FF2
What is a curtain collapse? Materials fall straight down
Lightweight trusses and Minutes
engineered floor systems can
fail in _________
Collapse of structures using Lightweight
_________ construction can
occur early in the incident
without warning
What type of buildings can Abandoned buildings
pose an even greater
danger of fire in collapse?
- building size
What features will affect the - compartmentation
length of time the structure - construction type
will maintain integrity under - fuel load
- Materials
heat exposure? (5 total)
The ______ can easily indicate Stage of the fire
the
quantity of heat that the
structure has been exposed
to and the potential for
structural collapse
Why is collapse more likely Due to the weakened state of structural members and the build
in the decay stage and up of water
during post-suppression
activities?
- generating higher temperatures
How can the contents within
- adding dead weight
the structure contribute to
- increasing weight from water retention
collapse? (3 total)
What are two ways you - preincidentplans
can gain knowledge of the - inspections
contents within a
structure?
A _______ must be established Collapse zone
adjacent to any exposed
exterior walls of the
3/66
, 6/29/25, 5:07 PM TCFP FF2
structure
Traditionally, collapse 1-1/2
zones have been
estimated by multiplying
the height of the structure
by a factor of ______
- indications that prolonged fire or heat has weakened the
structure
Collapse zones should be
established when: (3 -A defensive strategy has been adopted
total)
- Interior operations cannot be justified
- type of building construction
The size of a collapse zone
- other exposures
must take into
- safest location for apparatus and personnel
consideration the
following: (3 total)
- begin exiting the building, and inform command and all others
What 3 immediate action
inside
steps must be taken if
- establish and clear the collapse zone
firefighters suspect a - roll call
collapse?
When a collapse is To cautiously place unstaffed master stream devices and then
suspected, what is the only immediately withdraw
exception to personnel
working in the collapse
zone?
What are the two primary - conditions that contribute to the spread and intensity of the fire
types of
dangerous conditions that - conditions that make the building susceptible to collapse
may be posed by a
particular building?
What is one danger HVAC Ducts can move heated air and products of combustion
systems pose during a from involved compartments to other compartments
structure fire? within the structure
Every U.S. gallon of water 8 to 10
used to suppress fire adds
4/66