what improves temporal resolution - ✔ ✔ low line density, high
frame rate, narrow sector line, fewer pulse per frame
which of the following is true when the dynamic aperature is
increased - ✔ ✔ near zone length increases
Which of the following is the standard protocol for digital imaging
that allows compatibility and communication between computers,
workstations, and network hardware provided by various
manufacturers of CT, MRI, and ultrasound - ✔ ✔ DICOM
the beam of an unfocused transducer diverges in the - ✔ ✔
fraunhofer zone
A technique that uses an ensemble of pulses to improve penetration
and contrast resolution. - ✔ ✔ coded excitation
The Doppler shift frequency is - ✔ ✔ directly proportional to the
velocity of the reflector
A non-English-speaking patient presented for an ultrasound-guided
breast biopsy in which an informed consent is required. What is the
most appropriate step to take? - ✔ ✔ use a certified language line
The intensity of the ultrasound beam is usually greater at the focal
zone because of - ✔ ✔ smaller beam diameter
the operating frequency depends on the - ✔ ✔ crystal thickness
,the dynamic range of a system - ✔ ✔ Ratio of smallest to largest
power level
What term describes a digital imaging system that enables
ultrasound, x-ray, MRI, and CT images to be stored electronically and
viewed remotely on a workstation? - ✔ ✔ PACS
Which of the following best describes autocorrelation? - ✔ ✔ A
mathematical process in which a waveform is multiplied by time-shift
versions of itself
The acoustic impedance of a material is - ✔ ✔ equal to the product
of density and velocity
Ultrasound transducers convert - ✔ ✔ mechanical to electrical
A long near zone can be obtained by - ✔ ✔ using a higher
frequency transducer
What is the ratio of particle pressure to particle velocity at a given
point within the ultrasonic field? - ✔ ✔ impedance
The principle that states that all points on a wavefront can be
considered as point sources for the production of spherical secondary
wavelets was postulated by - ✔ ✔ huygens
Which of the following types of scan converter is used in current
ultrasound systems? - ✔ ✔ digital
Which of the following is a system performance parameter that is
assessed using a multipurpose phantom to determine the minimum
echo amplitude that can be detected? - ✔ ✔ sensitivity
, The major factor in determining the acoustic power output of the
transducer is the - ✔ ✔ magnitude of the pulser voltage spike
The extraneous beams of ultrasound not in the direction of the main
axis specific to multielement transducer arrays are called - ✔ ✔
Grating lobes result from multielement structures of transducer
arrays. Side lobes are similar to grating lobes but are created by
mechanical or single element transducers.
The refractive index of water is slightly altered when a sound beam
passes through it, thus causing compression and rarefaction of the
water molecules.
The phenomenon is the basis for what technique used to make
ultrasound beam measurements? - ✔ ✔ Schlieren photography
artifact deeper than it actually is - ✔ ✔ propagation speed error
the optimum operating frequency for a broad bandwidth transducer
is - ✔ ✔ 10
which of the following is not significantly affected by the limited field
of view when imaging superficial structures like the breasts - ✔ ✔
temporal res
the dynamic range of the display is teh - ✔ ✔ output power
amplitude of the transmitted voltag - ✔ ✔ output power
when you divide negative exponents you - ✔ ✔ divide
when you multiply negative exponents you - ✔ ✔ add