100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.6 TrustPilot
logo-home
Exam (elaborations)

Ultrasound Physics - Mock Exam Questions for SPI Exam Questions with Answers

Rating
-
Sold
-
Pages
20
Grade
A+
Uploaded on
22-06-2025
Written in
2024/2025

Ultrasound Physics - Mock Exam Questions for SPI Exam Questions with Answers-A 6 foot tall supine patient has normal hemodynamics. The patient's arterial blood pressure is 140 mmHg. The patient extends their right arm high above their head. What is the hydrostatic pressure at the ankle of this patient? a. 0 mmHg b. -50 mmHg c. 92 mmHg d. 50 mmHg e. 6 mmHg - 0 mmHg A higher mechanical index is consistent with an increased likelyhood of cavitation. Which of these choices is associated with a high mechanical index? a. extreme peak rarefactional pressure and short wavelength b. extreme peak rarefactional pressure and extremely short wavelength c. extreme peak rarefactional pressure and high frequency d. extreme peak compression pressure and high frequency e. extreme peak rarefactional pressure and low frequency - extreme peak rarefactional pressure and low frequency A linear sequential array probe has 128 crystals. In this case, how many of these will be fire silmultaneously for each sound pulse penetrating into the body? a, 1 b. 6 c. 128 d. 64 - 6 A single, disc shaped transducer crystal is 8 mm in diameter. The focal depth is 3 cm. The beam is unfocused. What is the diameter of the sound beam as it leaves the transducer? a. 2 mm b. 8mm c. 32 mm d. 16 mm e. 3 mm - 8mm A sonographer adjusts the outout of an ultrasound system by increasing the amplitude by a factor of three. Which of the following statements is true? a. power is increased by a factor of three b. wavelength is increased by a factor of nine c. power is increased by a factor of nine d. frequency in increased by a factor of three e. period is decreased by a factor of three - power is increased by a factor of nine A sonographer decreases the number of foci in an image from 4 to 2. Which of the following statements is most correct? a. lateral resolution decreases and temporal resolution increases b. lateral resolution increases and axial resolution increases c. axial resolution increases and temporal resolution decreases d. axial resolution increases and temporal resolution increases e. lateral resolution increases and temporal resolution decreases - lateral resolution decreases and temporal resolution increases A sonographer increases the number of foci from 1 to 4. Which of the following statements is most correct? a. lateral resolution decreases and temporal resolution increases b. lateral resolution increases and axial resolution increases c. axial resolution increases and temporal resolution decreases d. axial resolution increases and temporal resolution increases e. lateral resolution increases and temporal resolution decreases - Lateral resolution increases and temporal resolution decreases A sonographer is scanning a patient with a 3 MHz probe and replaces it with a 6 MHz probe. All of the following statements are FALSE, except: a. The 6 MHz beam will travel at a lower speed than the 3 MHz beam b. The 6 MHz beam will travel faster than the 3 MHz beam c. The 3 MHz beam will have a higher frequency than the 6 MHz beam d. The 6 MHZ beam will have a longer period than the 3 MHz beam e. The 3 MHz beam will have a longer wavelength than the 6 MHz beam - The 3 MHz beam will have a longer wavelength than the 6 MHz beam A sound beam is travelling from medium B to Medium G. Under which of the following conditions will reflection always occur? a. similar speeds, perpendicular incidence b. identical density and normal incidence c. dissimilar impedence and orthogonal incidence d. different density and oblique incidence e. different impedences and oblique incidence - dissimilar impedance and orthogonal incidence A sound wave is traveling in the body and propagates from muscle to air. What percentage of the sound wave is most likely reflected at the muscle-air boundary? a. 0.5% b. 75% c. 25% d. 5% e. 99% - 75%

Show more Read less
Institution
Ultrasound Physics.
Module
Ultrasound Physics.










Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
Ultrasound Physics.
Module
Ultrasound Physics.

Document information

Uploaded on
June 22, 2025
Number of pages
20
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
ProfMiaKennedy Arizona State University
View profile
Follow You need to be logged in order to follow users or courses
Sold
1990
Member since
5 year
Number of followers
1609
Documents
3279
Last sold
1 week ago

We all get stuck sometimes, you feel frustrated about exams coming up and not fully prepared? Worry no more mate, with my documents i assure you atleast an A, get unstuck with the most recent, analyzed and graded exams with just a simple mouse click... Download and crash those exams!!

3.9

380 reviews

5
195
4
57
3
56
2
25
1
47

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their exams and reviewed by others who've used these revision notes.

Didn't get what you expected? Choose another document

No problem! You can straightaway pick a different document that better suits what you're after.

Pay as you like, start learning straight away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and smashed it. It really can be that simple.”

Alisha Student

Frequently asked questions