Prophylactic cranial irradiation for ALL is administered to a total dose of: A. 1200 cGy B. 1800 cGy C. 3000 cGy D. 4500 cGy E. 6000 cGy - ANS B. 1800 cGy The treatment time for a field requiring 350 monitor units while the linear acellerator dose rate is 220 units/minute is: A. .394 minutes B. .629 minutes C. 1.59 minutes D. 2.52 minutes - ANS C. 1.59 minutes Placing marks on the central axis only is: A. Sufficient for daily realignment and targeting B. Sufficient when target margins are small C. Adequate for treating small fields RADIATION THERAPY BOARD REVIEW EXAM 2025 QUESTIONS AND ANSWERS COPYRIGHT © 2025 THESTAR ALL RIGHTS RESERVED 2 D. Insufficient for daily realignment and targeting - ANS D. Insufficient for daily realignment and targeting *Marks should be placed on the central axis and along coordinate planes to assure the patient and location target is accurately reproduced. During total CNS irradiation, the patient is: A. Supine with an extended chin B. Supine with chin flexed C. Prone with chin slightly extended D. Prone with chin flexed - ANS C. Prone with chin slightly extended Electron contamination from high energy photon beams may result from photon interactions with the: A. Room air B. Collimators C. Bolus D. Lucite trays - ANS B. Collimators Lucite is often used as the material for positioning devices. One major concern when this material is in the path of the treatment beam is: A. Electron contamination B. Beam attenuation C. Decreased rigidity D. Acquired radioactivity - ANS B. Beam attenuation COPYRIGHT © 2025 THESTAR ALL RIGHTS RESERVED 3 Advantages of networked digital image management do not include: A. Dispersed access to images B. Multiple users can share images C. Physical storage space is minimized D. Computer disk space is not an issue - ANS D. Computer disk space is not an issue In the treatment of seminoma, an external testicular shield should be used for the remaining testicle. This is Important since the TD 5/5 for the testis is as low as: A. 1 Gy B. 10 Gy C. 20 Gy D. 40 Gy - ANS A. 1 Gy Which of the following cannot produce a 3 dimensional image? A. MRI B. CT C. Ultrasound D. Electronic portal imaging - ANS D. Electronic portal imaging A procedure in which an implant is made using a trocar, with radioactive sources introduced into the trocar

Content preview

RADIATION THERAPY BOARD REVIEW
EXAM 2025 QUESTIONS AND ANSWERS


Prophylactic cranial irradiation for ALL is administered to a total dose of:


A. 1200 cGy
B. 1800 cGy
C. 3000 cGy
D. 4500 cGy

E. 6000 cGy - ANS B. 1800 cGy


The treatment time for a field requiring 350 monitor units while the linear acellerator dose rate
is 220 units/minute is:


A. .394 minutes
B. .629 minutes
C. 1.59 minutes

D. 2.52 minutes - ANS C. 1.59 minutes


Placing marks on the central axis only is:


A. Sufficient for daily realignment and targeting
B. Sufficient when target margins are small
C. Adequate for treating small fields

COPYRIGHT © 2025 THESTAR ALL RIGHTS RESERVED 1

,D. Insufficient for daily realignment and targeting - ANS D. Insufficient for daily realignment
and targeting


*Marks should be placed on the central axis and along coordinate planes to assure the patient
and location target is accurately reproduced.


During total CNS irradiation, the patient is:


A. Supine with an extended chin
B. Supine with chin flexed
C. Prone with chin slightly extended

D. Prone with chin flexed - ANS C. Prone with chin slightly extended


Electron contamination from high energy photon beams may result from photon interactions
with the:


A. Room air
B. Collimators
C. Bolus

D. Lucite trays - ANS B. Collimators


Lucite is often used as the material for positioning devices. One major concern when this
material is in the path of the treatment beam is:


A. Electron contamination
B. Beam attenuation
C. Decreased rigidity

D. Acquired radioactivity - ANS B. Beam attenuation


COPYRIGHT © 2025 THESTAR ALL RIGHTS RESERVED 2

,Advantages of networked digital image management do not include:


A. Dispersed access to images
B. Multiple users can share images
C. Physical storage space is minimized

D. Computer disk space is not an issue - ANS D. Computer disk space is not an issue


In the treatment of seminoma, an external testicular shield should be used for the remaining
testicle. This is Important since the TD 5/5 for the testis is as low as:


A. 1 Gy
B. 10 Gy
C. 20 Gy

D. 40 Gy - ANS A. 1 Gy


Which of the following cannot produce a 3 dimensional image?


A. MRI
B. CT
C. Ultrasound

D. Electronic portal imaging - ANS D. Electronic portal imaging


A procedure in which an implant is made using a trocar, with radioactive sources introduced
into the trocar and then the trocar is removed is called:


A. Self-attenuation
B. Interstitial preloading
COPYRIGHT © 2025 THESTAR ALL RIGHTS RESERVED 3

, C. Intracavitary microloading

D. Interstitial afterloading - ANS D. Interstitial afterloading


The precise daily reproduction of patient position depends on:


1. Patient age
2. Type of treatment machine
3. Anatomical site treated
4. Patients overall health


A. 1 & 2
B. 2 & 3
C. 3 & 4

D. 1 & 4 - ANS C. 3 & 4


The linear scales on the treatment table are used as an aid for:


A. Translation of patient position on the table
B. Verifying filament voltage
C. Verifying gantry readout accuracy

D. Documentation of treatment dose - ANS A. Translation of patient position on the table


Compared to water, the density of bone is:


A. 1.00
B. 1.65-1.85
C. 0.33-0.35

COPYRIGHT © 2025 THESTAR ALL RIGHTS RESERVED 4

Document information

Uploaded on
June 16, 2025
Number of pages
66
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$14.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
TheStar
3.7
(140)
Sold
710
Followers
178
Items
26818
Last sold
1 day ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions