NFPA 10 UPDATED EXAM QUESTIONS WITH CORRECT ANSWERS AND VERIFIEDLOW PRESSURE CYLINDER - CORRECT ANSWERCONTAINS FIRE EXTINGUISHER AGENT (MEDIUM), NITROGEN, COMPRESSED AIR, OR OTHER COMPRESSED GASES AT A SERVICE PRESSURE OF 500 PSI OR LOWER AT 70 DEGREES F. DOT - CORRECT ANSWERU.S. DEPARTMENT OF TRANSPORTATION ELECTRONIC MONITORING - CORRECT ANSWERA METHOD OF ELECTRONIC COMMUNICATION (DATA TRANSMISSION) BETWEEN AN IN-PLACE FIRE EXTINGUISHER AND AN ELECTRONIC MONITORING DEVICE/SYSTEM. FILM-FORMING FOAM AGENTS - CORRECT ANSWERAQUEOUS FILM-FORMING FOAM (AFFF) AND FILM-FORMING FLUOROPROTEIN FOAM (FFFP). HYDRO-STATIC TESTING - CORRECT ANSWERPRESSURE TESTING OF THE EXTINGUISHER TO VERIFY ITS STRENGTH AGAINST UNWANTED RUPTURE.

Content preview

NFPA 10 UPDATED EXAM QUESTIONS WITH
CORRECT ANSWERS AND VERIFIED.

HIGH PRESSURE CYLINDER - CORRECT ANSWER✅✅✅CONTAINS NITROGEN, COMPRESSED AIR,
CARBON DIOXIDE OR OTHER GASES AT A PRESSURE HIGHER THAN 500 PSI AT 70 DEGREES F.



LOW PRESSURE CYLINDER - CORRECT ANSWER✅✅✅CONTAINS FIRE EXTINGUISHER AGENT
(MEDIUM), NITROGEN, COMPRESSED AIR, OR OTHER COMPRESSED GASES AT A SERVICE PRESSURE OF
500 PSI OR LOWER AT 70 DEGREES F.



DOT - CORRECT ANSWER✅✅✅U.S. DEPARTMENT OF TRANSPORTATION



ELECTRONIC MONITORING - CORRECT ANSWER✅✅✅A METHOD OF ELECTRONIC COMMUNICATION
(DATA TRANSMISSION) BETWEEN AN IN-PLACE FIRE EXTINGUISHER AND AN ELECTRONIC MONITORING
DEVICE/SYSTEM.



FILM-FORMING FOAM AGENTS - CORRECT ANSWER✅✅✅AQUEOUS FILM-FORMING FOAM (AFFF)
AND FILM-FORMING FLUOROPROTEIN FOAM (FFFP).



HYDRO-STATIC TESTING - CORRECT ANSWER✅✅✅PRESSURE TESTING OF THE EXTINGUISHER TO
VERIFY ITS STRENGTH AGAINST UNWANTED RUPTURE.



LOADED STREAM CHARGE - CORRECT ANSWER✅✅✅A WATER-BASED EXTINGUISHING MEDIUM
THAT USES AN ALKALI METAL SALT AS A FREEZING POINT DEPRESSANT.



ICC - CORRECT ANSWER✅✅✅THE INTERSTATE COMMERCE COMMISSION, WHICH HAD
JURISDICTION OVER HIGH-PRESSURE CYLINDERS AND CARTRIDGES PRIOR TO 1967.



MILD STEEL SHELL - CORRECT ANSWER✅✅✅ALL STEEL SHELLS OTHER THAN STAINLESS STEEL AND
STEEL SHELLS USED FOR HIGH-PRESSURE CYLINDERS.

,PERFORMANCE STANDARDS-DRY CHEMICAL - CORRECT ANSWER✅✅✅ANSI/UL 299, STANDARD FOR
DRY CHEMICAL FIRE EXTINGUISHERS; CAN/ULC-S504, STANDARD FOR DRY CHEMICAL FIRE
EXTINGUISHERS



FIRE EXTINGUISHER LABEL - CORRECT ANSWER✅✅✅CONTENT'S PRODUCT NAME AS IT APPEARS ON
MSDS.

LIST OF HAZARDOUS MATERIAL IDENTIFICATION.

MANUFACTURER'S OR SERVICE AGENCY:

NAME, MAILING ADDRESS, AND PHONE NUMBER.



OBSOLETE FIRE EXTINGUISHER - CORRECT ANSWER✅✅✅SHALL BE REMOVED FROM SERVICE...

PRESSURIZED WATER FIRE EXTINGUISHERS MANUFACTURED PRIOR TO 1971.

ANY EXTINGUISHER THAT NEEDS TO BE INVERTED TO OPERATE.

ANY STORED PRESSURE EXTINGUISHER MANUFACTURED PRIOR TO 1955.

ANY EXTINGUISHERS WITH 4B, 6B, 8B, 12B AND 16B FIRE RATINGS.

STORED PRESSURE WATER EXTINGUISHERS WITH FIBERGLASS SHELLS (PRE-1976).

DRY CHEMICAL STORED PRESSURE EXTINGUISHERS MANUFACTURED PRIOR TO OCTOBER 1984 SHALL BE
REMOVED FROM SERVICE AT THE NEXT 6 YEAR MAINTENANCE OR THE NEXT HYDROTEST INTERVAL.

ANY FE THAT CAN NO LONGER BE SERVICED IN ACCORDANCE WITH THE MANUFACTURER'S
MAINTENANCE MANUAL.



CLASSIFICATION OF FE:

CLASS A (A IS IN ASH) - CORRECT ANSWER✅✅✅ORDINARY COMBUSTIBLE MATERIAL: WOOD,
CLOTH, PAPER, RUBBER, MANY PLASTICS.



CLASSIFICATION OF FE:

CLASS B

(B AS IN BARREL-ITEMS STORED IN BARRELS) - CORRECT ANSWER✅✅✅FLAMMABLE LIQUIDS,
COMBUSTIBLE LIQUIDS, PETROLEUM GREASES, TARS, OILS, OIL-BASED PAINTS, SOLVENTS, LACQUERS,
ALCOHOLS, AND FLAMMABLE GASES.

, CLASSIFICATION OF FE:

CLASS C (ELECTRICAL CURRENT) - CORRECT ANSWER✅✅✅ELECTRICAL EQUIPMENT



CLASSIFICATION OF FE:

CLASS D - CORRECT ANSWER✅✅✅COMBUSTIBLE METALS, SUCH AS: MAGNESIUM, TITANIUM,
ZIRCONIUM, SODIUM, LITHIUM, AND POTASSIUM.



CLASSIFICATION OF FE:

CLASS K (KITCHENS) - CORRECT ANSWER✅✅✅COMBUSTIBLE COOKING MEDIA (VEGETABLE OR
ANIMAL OILS AND FATS).



CLASS A OR CLASS B FIRE EXTINGUISHERS - CORRECT ANSWER✅✅✅REQUIRED TO HAVE RATING
NUMBER AFTER LETTER(INDICATES EFFECTIVENESS).



CLASS C , CLASS D, OR CLASS K

FIRE EXTINGUISHERS - CORRECT ANSWER✅✅✅NO NUMBER REQUIRED PRECEDING LETTER.



HALOGENATED FIRE EXTINGUISHERS - CORRECT ANSWER✅✅✅AGENT USED TO EXTINGUISH FIRE
WITHOUT DAMAGING EQUIPMENT.



CLASSIFY OCCUPANCY HAZARD - CORRECT ANSWER✅✅✅ROOMS OR AREAS CLASSIFIED BY

LIGHT (LOW)

ORDINARY (MODERATE)

EXTRA (HIGH)



LIGHT (LOW) OCCUPANCY HAZARD - CORRECT ANSWER✅✅✅CLASS A COMBUSTIBLES (WOOD,
CLOTH, PAPER, RUBBER, PLASTICS)

Document information

Study
Uploaded on
June 16, 2025
Number of pages
26
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$9.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Sold
1
Followers
0
Items
934
Last sold
9 months ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.