BICSI 1 & 2

'Through' and 'membrane' are the two types of - ANS-Penetrations

[Triangle] - ANS-Work Area

0 dB = - ANS-1 mW @ 1004Hz across an impedance of 600 ohm

1 ohm of resistance will allow - ANS-one ampere of current to flow when one volt is applied

1,000 Hz is - ANS-1 kHz

1,000,000 Hz is - ANS-1MHz

1,000,000,000 Hz is - ANS-1GHz

110 frames are available in - ANS-50, 100, 300, and 900 pair count

25 Pair telephone Color Code: - ANS-White, Red, Black, Yellow, Violet

4 Pair cable - ANS-Shielded or non-shielded, 22-26 AWG, Solid conductors for Backbone or
Horizontal cabling

4P4C - ANS-Phone

6P6C - ANS-Phone and modem

8P8C - ANS-Data

A ____ is not a style of splice enclosure - ANS-Bridge

a _____ is not a 25pair modular splicing connector configuration - ANS-Butt

A B Cs - ANS-Airway, Breathing, Circulation

A power strip supporting dual-corded-equipment should be loaded to no more than ____ of the
circuit capacity - ANS-40%

Ablative - ANS-Develops a hard char

Ablative fire-stop materials - ANS-develop a hard char and become rigid

,AHJ - ANS-Athority having jurisdiction

Alien crosstalk(AXT) - ANS-Unwanted signal transfer from one pair in a cable to another pair in
another cable.

An analog signal varies in what two aspects - ANS-Amplitude and tone

An installer must be a highly skilled professional, a ____ member and _____ learner -
ANS-Team, ongoing

Analog signals - ANS-Utilize continuously varying electrical signals

ANSI/J-STD-607-A - ANS-Commercial Building Grounding and Bonding Requirements for
Telecommunications

ANSI/TIA/EIA-568-C.2 - ANS-Balanced Twisted Pair Telecommunications Cabling and
Component Standards

ANSI/TIA/EIA-568-C.3 - ANS-Optical Fiber Cabling Component Standards

ANSI/TIA/EIA-570-B - ANS-Residential Telecommunications Infrastructure Standard 2004

ANSI/TIA/EIA-606-A - ANS-Administration Standard for Commercial Telecommunications
Infrastructure

ANSI/TIA/EIA-606-A Class 1 - ANS-Building Served by single ER

ANSI/TIA/EIA-606-A Class 2 - ANS-Building served by more than one telecommunications
space

ANSI/TIA/EIA-606-A Class 3 - ANS-Multiple building at one site

ANSI/TIA/EIA-606-A Class 4 - ANS-Multiple site or campuses

Area in a Data Center that contains equipment cabinets or racks - ANS-ZDA

Area in a Data Center that contains the core LAN and SAN switches? - ANS-MDA

Area in a Data Center that contains the HC - ANS-HDA

Area in a Data Center that contains the optional interconnect where an equipment outlet or
consolidation point may be located - ANS-ZDA

, Area in a Data Center that containsthe intermediate cross-connect and possibily a second layer
backbone - ANS-IDA

ASTM - ANS-American Society of Testing Materials

Attenuation to crosstalk Ratio(ACR-F) - ANS-Derived from subtracting the insertion loss of the
distributor pair from the cable's FEXT measurement. The higher the dB the better.

AWG - ANS-American wire gauge. 36 AWG(5 mil) smallest, 4/0 AWG largest(460 mil)

Backbone Cables - ANS-Interconnect TRs, ERs, EFs.

Backbone conduits should - ANS-Terminate where they enter the TR or ER, grounding
bushings, 1-3" AFF

Balanced cable(UTP) has - ANS-same voltage on each conductor in reference to ground

Bandwidth is - ANS-The range between the highest and the lowest frequencies of a
communications component

BICSI - ANS-Building Industry Consulting Service International

BICSI recommends only _____ cables be installed inside commercial buildings - ANS-Listed

BICSI recommends what width of cable tray be mounted on backboards - ANS-12 in

Bix frames are available in - ANS-50, 250, 300, and 900 pair count

Cable trays are used - ANS-between TRs, and from TRs to work areas. Made of steel or
aluminum, styles: Tubular, solid bar, Rod.

Cabling companies depend on _____ for new and repeat business - ANS-Customers

Capacitance is - ANS-A property of conductors that allows storage of electrical charges when
potential differences exist

Capacitance is measured in - ANS-farads(micro 1/millionth, nano 1/billionth, pico 1/trillionth)

CAT3 - ANS-16 MHz

CAT5 - ANS-100 MHz

Cat5 UTP has a transmission characteristic of up to - ANS-100MHz

Document information

Uploaded on
June 14, 2025
Number of pages
19
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$15.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Eduhprofe
3.5
(2)
Sold
9
Followers
0
Items
1109
Last sold
7 months ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions