and Usable Buildings and Facilities
ICC A117.1-2017 Standard for Accessible
and Usable Buildings and Facilities
The _______________ of carpet or carpet tile shall be ____ inches maximum in height? - ANSWER pile,
1/2
Changes in level of ____ inches _______________ in height shall be permitted to be _______________?
- ANSWER 1/4, maximum, vertical
Changes in level greater than ____ inches in _______________ and not more than ____ inches
maximum in height shall be _______________ with a slope not _______________ than 1:2? - ANSWER
1/4, level, 1/2, beveled, steeper
The maximum slope of any floor surface shall not be permitted to be greater than ____? - ANSWER 1:48
Objects with leading edges not more than ____ inches and not more than ____ inches above the
_________________ shall protrude ____ inches horizontally into a ________________ path? - ANSWER
27, 80, floor, 4, horizontally, circulation
Operable parts shall be operable with ____ hand and shall not require tight _________________,
_______________, or ________________ of the wrist. The force required to activate operable parts
shall be ____ pounds maximum? - ANSWER 1, grasping, pinching, twisting, 5
The minimum clear width of an interior accessible route shall be ____ inches minimum? - ANSWER 36
The minimum clear width of an exterior accessible route shall be ____ inches minimum? - ANSWER 48
For maneuvering clearances at manual swinging doors, front approach, pull-side reference? - ANSWER
ICC A117.1-2017, page 26