• Wrong document? Swap it for free
  • Written by students who passed
  • Immediately available after payment
  • Read online or as PDF
Sell
Where do you study
Your language
Document preview thumbnail
Preview 2 out of 7 pages
Exam (elaborations)

MDCB Exam 2 – Verified Advanced Questions and Clinical Dosimetry Answers

Document preview thumbnail
Preview 2 out of 7 pages

This document contains a high-level set of verified questions and answers from MDCB Exam 2, targeting complex dosimetric and radiobiological scenarios. Key concepts include SSD vs SAD treatment errors, Cesium-137 decay, isodose normalization, TMR/TPR/OAR definitions, field matching angles, dose-limiting organs (lungs, spinal cord), QA tolerances (TG-40), craniospinal technique corrections, inhomogeneity corrections, and photoelectric interactions. Also included are advanced electron arc therapy cases, HDR planning, and survival curve interpretations. Ideal for experienced candidates preparing for the MDCB board exam.

Content preview

MDCB EXAM 2 questions with verified answers
A dose of 30 Gy in 10 fractions to a depth of 7 cm from a 6 MV single
posterior field using an isocentric technique at 100 cm source-to-axis
distance (SAD). The patient was incorrectly treated five times at 100 cm
source-to-surface distance (SSD). The approximate dose at 7 cm after
five fractions is: Ans✓✓✓ 13.1 Gy


A four-field isocentric isodose plan normalized to 100% at the isocenter
shows the entire target volume encompassed by the 97% isodose line.
The target volume is to receive 65 Gy; however, it is required that the
dose be prescribed at the isocenter. The dose prescription should be
written for: Ans✓✓✓ 67 Gy to the isocenter


A patient is inadvertently treated using the 18 MV photon energy
instead of the prescribed 6 MV. The prescribed dose is 200 cGy to 5 cm
depth at 100 cm SSD. If the calculated monitor units (MUs) were
delivered, what is the dose delivered to 5 cm depth?
18 MV unit 6 MV unit
tray factor = 0.981 tray factor 0.970
output factor = 0.989 cGy/MU output factor = 0.994 cGy/MU
%DD (5 cm) = 96.5% %DD (5 cm) = 86.6% Ans✓✓✓ 225 cGy


A patient is treated to the left chest wall with electron arc therapy. In
order to sharpen the distribution at the medial and lateral field borders,
the medical dosimetrist should: Ans✓✓✓ shape the field on the skin
surface with lead strips

, A simulation is done for a treatment to be given isocentrically, source-
axis distance 80 cm, and with a field size of 5 cm x 12.5 cm. The image
of the field size on the radiograph measures 6 cm x 15 cm. What is the
actual size of an object placed on the patient's surface, 72 cm from the
source, if the image of the object on the radiograph measures 4 cm?
Ans✓✓✓ 3 cm


According to the American Association of Physicists in Medicine (AAPM)
standards (TG40), when periodic linear accelerator quality assurance
procedures are performed, which of the following is the acceptable
tolerance for an optical distance indicator? Ans✓✓✓ ± 2.0 mm


According to the American Association of Physicists in Medicine (AAPM)
standards (TG40), when periodic linear accelerator quality assurance
procedures are performed, which of the following is the acceptable
tolerance for field size indicators? Ans✓✓✓ ± 2.0 mm


According to the National Council on Radiation Protection and
Measurements (NCRP) guidelines (#116), the annual equivalent dose
limit for the hands of an occupational worker in 1 year is: Ans✓✓✓ 500
mSv (50 rem)


After 6.5 years, the activity of a 25 mCi Cesium-137 source will be:
Ans✓✓✓ 21.5 mCi

Document information

Uploaded on
June 9, 2025
Number of pages
7
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$16.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
cracker
3.8
(402)
Sold
2180
Followers
1346
Items
50083
Last sold
3 days ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their exams and reviewed by others who've used these revision notes.

Didn't get what you expected? Choose another document

No problem! You can straightaway pick a different document that better suits what you're after.

Pay as you like, start learning straight away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and smashed it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions