Two Towers are both 125 feet high, when full, contain 122 feet of water. Tower 1 holds 150,000
gallons. Tower 2 holds 500,000 gallons. Each has a pressure gauge at the base. Which will
register the most pressure in psi? - (ANSWER)Both will be equal



If the water level in tower 1 is 118 feet what will the pressure reading be at the base -
(ANSWER)51.1 psi



What is the definition of potable water - (ANSWER)Water that does not contain objectable
pollution, contamination, or infective agents and is considered safe for drinking



What is the first item used when installing a service line to a customer? -
(ANSWER)Corporation stop


If a meter to a residence is located in the basement what should be located between the water
main and the house - (ANSWER)curb stop


A 5/8" x 3/4" water meter serves a residence. Over a period of years the meter __________ in
recording actual water used - (ANSWER)Decreases


To isolate part of a distribution system what type of valve is commonly used? -
(ANSWER)Gate valve


Trihalomethanes (THMs) are caused by? - (ANSWER)Reaction of chlorinated water with
numeric materials found in surface water sources

,The longer the contact time water and chlorine residuals enjoy the ________ the THM level will
probably be - (ANSWER)Higher



THM's should be eliminated from finished water because they cause ? - (ANSWER)Cancer



The maximum contaminant level for THM's is? - (ANSWER).080 mg/l


When collecting THM samples one sample must be taken at a site where the water has been in
the distribution system the longest time - (ANSWER)True


An applicant for a class d test who has graduated high school but has no approved training
credits must have ____________ "hands on" experience - (ANSWER)6 months


What type of water main is most likely to become contaminated from gasoline saturated soil -
(ANSWER)PVC



What type of materials must not be used as backfill for water mains? - (ANSWER)Cinders



Nitrate in levels above _________ mg/L can cause "blue baby" disease - (ANSWER)10



A boil order must be issued if systems pressure drops below 20 psi or if contaminated of any part
of the system is suspected. Why? - (ANSWER)It is a regulation of the IEPA, and to protect the
health of water consumers



A boil order should be issued for? - (ANSWER)Until further notice


Upon the issuance of a boil order the IEPA regional office should be notified of the order because
________________? - (ANSWER)It's a state regulation

, The "C" factor of a pipe is _______________? - (ANSWER)The smoothness of the interior of a
pipe



The higher the "C" factor of a pipe the _____________ the pipe and the greater the carrying
capacity of the pipe - (ANSWER)Smoother



A distribution system that is "looped" instead of having dead ends will help prevent -
(ANSWER)Tastes and odors, "dirty" water, and chlorine depletion



Chlorine tablets (calcium hypochlorite) should be used for the disinfection of newly installed
water main. These tablets should be ________________ - (ANSWER)Glued to the top of each
section



What is the definition of a water main? - (ANSWER)Any line that passes one property to reach
another parcel of property



What is the minimum size of a water main required by the IEPA - (ANSWER)4 inches in
diameter



Is a construction permit from the IEPA permit section required for the installation of a water
main? - (ANSWER)Yes



Is a construction permit from the IEPA permit section required for the installation of a water
service? - (ANSWER)No



A three-quarter inch service line is tapped on a water main. The corporation stop should be
installed__________________ - (ANSWER)At an angle between the top and side of the main



A 6 inch PVC Watermain is installed what should be installed at the end of the main -
(ANSWER)Concrete thrusting block

Document information

Uploaded on
June 3, 2025
Number of pages
17
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$16.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
PREMIUMTESTS
4.9
(231)
Sold
1117
Followers
5
Items
1031
Last sold
3 months ago


Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions