Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Document preview thumbnail
Preview 2 out of 15 pages
Exam (elaborations)

HERS Rater exam questions with correct answers

Document preview thumbnail
Preview 2 out of 15 pages

HERS Rater exam questions with correct answers

Content preview

HERS Rater exam questions with correct \| \| \| \| \| \|




answers


What do HERS Providers provide? - CORRECT ANSWERS ✔✔They provide
\| \| \| \| \| \| \| \| \| \|




software, oversight, marketing assistance, and quality assurance for the Rater.
\| \| \| \| \| \| \| \| \|




What role does a HERS Trainer play? - CORRECT ANSWERS ✔✔The Trainer
\| \| \| \| \| \| \| \| \| \| \| \|




trains Raters on how to perform HERS ratings.
\| \| \| \| \| \| \|




What are some of the responsibilities of a HERS Rater? - CORRECT
\| \| \| \| \| \| \| \| \| \| \| \|




ANSWERS ✔✔The Rater's responsibilities include inspecting and testing the
\| \| \| \| \| \| \| \| \|




minimum rated features of the home, entering the data into a RESNET
\| \| \| \| \| \| \| \| \| \| \| \|




accredited software tool, and providing the client with reports generated by the
\| \| \| \| \| \| \| \| \| \| \|




software.
\|




Why was RESNET created and by whom? - CORRECT ANSWERS
\| \| \| \| \| \| \| \| \| \|




✔✔RESNET was created to use a scoring system that could compare the
\| \| \| \| \| \| \| \| \| \| \| \|




energy use of different houses with each other on a level playing field. It was
\| \| \| \| \| \| \| \| \| \| \| \| \| \| \|




created to oversee the HERS industry, provide standards for accreditation of
\| \| \| \| \| \| \| \| \| \| \|




Raters, Providers and Trainers, ethics and protocols for inspection, testing and
\| \| \| \| \| \| \| \| \| \| \|




software analysis. It was created by the National Association of State Energy
\| \| \| \| \| \| \| \| \| \| \| \|




Officers (NASEO) and Energy Rated Homes of America.
\| \| \| \| \| \| \|




What are the minimum rated features of a home? - CORRECT ANSWERS
\| \| \| \| \| \| \| \| \| \| \| \|




✔✔The minimum rated features of a home include but are not limited to the
\| \| \| \| \| \| \| \| \| \| \| \| \| \|

, foundation, walls, roof-ceiling, rim joist, doors, windows, skylights, air
\| \| \| \| \| \| \| \| \|




infiltration, heating and cooling equipment, heating and cooling distribution
\| \| \| \| \| \| \| \| \|




system, duct leakage, domestic water heating, passive solar design, and solar
\| \| \| \| \| \| \| \| \| \| \|




water heating. \|




Can any energy analysis software be used to produce a HERS rating? -
\| \| \| \| \| \| \| \| \| \| \| \| \|




CORRECT ANSWERS ✔✔No -- The software must be a RESNET accredited\| \| \| \| \| \| \| \| \| \| \|




software tool. \|




Is a Home Energy Rater required to verify compliance with the local energy
\| \| \| \| \| \| \| \| \| \| \| \| \|




code? - CORRECT ANSWERS ✔✔No - The rater is not required to determine
\| \| \| \| \| \| \| \| \| \| \| \| \|




compliance with regulatory requirements such as construction codes. \| \| \| \| \| \| \|




If a Rater enters an existing home to perform inspections and testing and the
\| \| \| \| \| \| \| \| \| \| \| \| \| \|




owner's 9 foot Burmese python is loose, does the Rater have to complete the
\| \| \| \| \| \| \| \| \| \| \| \| \| \|




inspection and testing? - CORRECT ANSWERS ✔✔No - The Rater is not
\| \| \| \| \| \| \| \| \| \| \| \|




required to enter any area or perform any procedure that is likely to be
\| \| \| \| \| \| \| \| \| \| \| \| \| \|




dangerous to the Rater. \| \| \|




Is a Rater required to perform Manual J load calculations? - CORRECT
\| \| \| \| \| \| \| \| \| \| \| \|




ANSWERS ✔✔No - The Rater is not required to offer or perform HVAC\| \| \| \| \| \| \| \| \| \| \| \| \|




system design or sizing consultation.
\| \| \| \|




What is a British thermal unit? - CORRECT ANSWERS ✔✔A British thermal
\| \| \| \| \| \| \| \| \| \| \| \|




unit (Btu) is the amount of heat required to raise the temperature of one
\| \| \| \| \| \| \| \| \| \| \| \| \| \|




pound of water on degree Fahrenheit at sea level when the water is 39.2°F.
\| \| \| \| \| \| \| \| \| \| \| \| \|

Document information

Uploaded on
May 31, 2025
Number of pages
15
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$19.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
EXAMSTUDYPLUG
4.5
(242)
Sold
381
Followers
108
Items
20774
Last sold
3 days ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions