• Wrong document? Swap it for free
  • Written by students who passed
  • Immediately available after payment
  • Read online or as PDF
Sell
Where do you study
Your language
Document preview thumbnail
Preview 1 out of 2 pages
Exam (elaborations)

Iahcsmm Crcst Chapter 13 || 100% Solved Solutions!!

Document preview thumbnail
Preview 1 out of 2 pages

IUSS correct answers immediate use steam sterilization(flash sterilization) Point of use processing correct answers Processing a medical device immediately before use, and/or close to patient care area IUSS correct answers Process designed for the cleaning, steam sterilization and delivery of patient care items for immediate use. Terminal Sterilization correct answers Sterilizing wrapped instruments in a full cycle. AORN does not recognize IUSD sterilization for implants correct answers According to the FDA, an implant is an item that is placed into a surgically or naturally formed body cavity to remain for 30 days or more. correct answers 4 IUSS Cycles correct answers 1. Gravity Displacement 2. Pre-vacuum 3. Steam-Flush Pressure-pulse 4. Express (Not always available) IUSS Cycle Times correct answers 12-30 mins gravity sterilizer conditions correct answers temp 250-254 degrees f, 15-17 psi, and minimum exposed of fifteen minutes Pre vac and Gravity time correct answers 270 4 min 20-30 dry time Pre-vac 250 30 min 15-30 dry time gravity Pre-Vacuum Steam Sterilizer Steam Flush Pressure-Pulse (SFPP) correct answers Steam sterilizers that use an active air removal system. Gravity displacement sterilizer correct answers A type of sterilizer that removes air by gravity. condition phase correct answers steam enters chamber, air is forced out or mechanically removed. temperature and pressure increase. Exposure Phase of Steam Sterilization correct answers When steam is exposed for 3, 4 or 10 mins Exhaust Phase of Steam Sterilization correct answers filtered air enters, steam is removed from chamber, and pressure inside returns to atm pressure in chamber correct answers Steam pressure and jacket gauges pressure must both be equal during exposure phases

Content preview

IAHCSMM CRCST Chapter 13 || 100% SOLVED
SOLUTIONS!!
IUSS correct answers immediate use steam sterilization(flash sterilization)

Point of use processing correct answers Processing a medical device immediately before use,
and/or close to patient care area

IUSS correct answers Process designed for the cleaning, steam sterilization and delivery of
patient care items for immediate use.

Terminal Sterilization correct answers Sterilizing wrapped instruments in a full cycle.

AORN does not recognize IUSD sterilization for implants correct answers

According to the FDA, an implant is an item that is placed into a surgically or naturally
formed body cavity to remain for 30 days or more. correct answers

4 IUSS Cycles correct answers 1. Gravity Displacement
2. Pre-vacuum
3. Steam-Flush Pressure-pulse
4. Express (Not always available)

IUSS Cycle Times correct answers 12-30 mins

gravity sterilizer conditions correct answers temp 250-254 degrees f, 15-17 psi, and minimum
exposed of fifteen minutes

Pre vac and Gravity time correct answers 270 4 min 20-30 dry time Pre-vac
250 30 min 15-30 dry time gravity

Pre-Vacuum Steam Sterilizer
Steam Flush Pressure-Pulse (SFPP) correct answers Steam sterilizers that use an active air
removal system.

Gravity displacement sterilizer correct answers A type of sterilizer that removes air by
gravity.

condition phase correct answers steam enters chamber, air is forced out or mechanically
removed. temperature and pressure increase.

Exposure Phase of Steam Sterilization correct answers When steam is exposed for 3, 4 or 10
mins

Exhaust Phase of Steam Sterilization correct answers filtered air enters, steam is removed
from chamber, and pressure inside returns to atm

pressure in chamber correct answers Steam pressure and jacket gauges pressure must both be
equal during exposure phases

Document information

Uploaded on
May 23, 2025
Number of pages
2
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$8.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
ProPerfomer
3.8
(84)
Sold
448
Followers
322
Items
8858
Last sold
11 hours ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions