Ohio fire alarm

A ____ is an unwanted alarm that occurred when there is no hazard condition present - ANS -Unwanted alarm
\A _____ is an unwanted activation of signaling or an alarm initiating device in response to a stimulus or condition that is
not the result of potentially hazardous condition - ANS -Nuisance Alarm
\A ______ is an unwanted activation of an alarm initiating or system output function where the cause is not been identified
- ANS -Unknown alarm
\A bi-metallic heat detector is an example of a - ANS -spot type detector
\A coded alarm signal shall consist of not less than _____ rounds of the number transmitted - ANS -3
\A detector should not be recessed in any way unless they have been tested for such a mounting - ANS -True
\A device which detects the visible particles of combustion is a ____ detector - ANS -Smoke
\a fire alarm system is required to have _____ sources of power - ANS -2
\a fire alarm system must operate on standby for a period of not less than ______ days followed by at least ______
minutes of alarm - ANS -7/4
\A flow switch is an ____ type of device - ANS -On / Off
\a heat detector integrally mounted on a smoke detector shall be listed and approved for not less than - ANS -50'
\A line-type obsucration smoke detector, where the light beam is projected across the area to be protected - ANS
-projected beam smoke detector
\A person with a fire alarm license may supervise ____ provisional certification personnel - ANS -One
\A pressure supervisory signal initiating devices for a dry pipe pipe sprinkler system shall indicate both... - ANS -True
\A pressure tank supervisory signal initiating device for a pressurized limited water supply such as a pressure tank shall
indicate both high- and low-pressure conditions - ANS -True
\A secondary power supply shall have sufficient capacity to operate the system under a non alarm condition for a
minimum of ___ hours and ____ minutes under a full load - ANS -24/5
\a signaling method characterized by simultaneous or sequential transmission on both, and reception of multiple signals
on a signaling line circuit, a transmission channel, or a communications channel, including means for positively identifying
each signal. - ANS -Multiplexing

, \A spot-type heat detector located on a wall shall not be more than _____ inches from the ceiling - ANS -12''
\A type of smoke detector which uses a small amount of radioactive material is an - ANS -ionization detector
\A water flow device should be field adjusted so that an alarm is initiated in no more than _____ seconds - ANS -90
seconds
\Actuation of alarm notification appliances or emergency voice communications. fire alarm safety functions, and
annunciation at the protected premises shall occur within _____ seconds after the activation of the initiating device - ANS
-10 seconds
\Actuation of alarm, notification appliances, or emergency communication and enunciation shall occur within ____ after
the activation of ana intuiting device - ANS -10 seconds
\Alarm signals shall take precedence over any other signal or first non fire signal if activated first - ANS -True
\All fire detection devices shall be listed or approved for the purpose for which they are intended - ANS -True
\All household fire alarm equipment should have enough back up power to sound an alarm for _____ minutes - ANS -4
minutes
\All notification appliances, including voice, textual, and visual are required to be listed for the purpose for which they are
used - ANS -True
\All pneumatic line type heat detectors shall be tested for leak and proper operations at six month intervals - ANS -False
\An average ambient sound level greater than ______ shall require the use of a visible notification appliance - ANS
-105dba
\Are smoke detectors permitted to be in air stream - ANS -No
\Area smoke detectors within smoke compartments shall be used to control the spread of smoke by initiating operating
controls and other equipment - ANS -True
\Audible alarm notification devices shall provide a sound level of _____ dBa above the average ambient sound level or
___ dBa above the maximum sound level having a duration of at least 60 seconds, whichever is greater, in every
occupied space - ANS -15/5 dBa
\Carbon monoxide signal requires what kind of action - ANS -Immediate Action
\Carbon monoxide signals shall be permitted to take precedence over ___ - ANS -supervisory and trouble signals
\Central stations are offices which provide alarm and supervisory service and are located on the protected premises -
ANS -False

Document information

Uploaded on
May 20, 2025
Number of pages
8
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$14.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
ALICE12
3.9
(33)
Sold
141
Followers
16
Items
2062
Last sold
1 week ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions