MKC SWE EXAM QUESTIONS AND ANSWERS 100% CORRECTMKC SWE EXAM QUESTIONS AND ANSWERS 100% CORRECTMKC SWE EXAM QUESTIONS AND ANSWERS 100% CORRECT TCTO - ANSWER-Technical Change Training Order Non-Self Righting Small Boats less than 65 feet in length for - ANSWER-Changes that create more than a 0.002 ft change in the center of gravity in any direction (vertical, longitudal or transverse) or net weight changes of more than 1/5 of 1% of the full load displacement All other Assets require TCTO for - ANSWER-Changes that create more than a 0.001 ft change in center of gravity (vertical, long, trans) or net weight changes of more than 1/20 of 1% of the full load displacement require TCTO. Weight Change Threshold - ANSWER-1/5 of 1% of full load displacement for small boats. TCTO Requirement for Other Assets - ANSWER-0.001 ft center of gravity change triggers TCTO.

Content preview

MKC SWE EXAM QUESTIONS AND
ANSWERS 100% CORRECT
TCTO - ANSWER-Technical Change Training Order

Non-Self Righting Small Boats less than 65 feet in length for - ANSWER-Changes that
create more than a 0.002 ft change in the center of gravity in any direction (vertical,
longitudal or transverse) or net weight changes of more than 1/5 of 1% of the full load
displacement

All other Assets require TCTO for - ANSWER-Changes that create more than a 0.001 ft
change in center of gravity (vertical, long, trans) or net weight changes of more than
1/20 of 1% of the full load displacement require TCTO.

Weight Change Threshold - ANSWER-1/5 of 1% of full load displacement for small
boats.

TCTO Requirement for Other Assets - ANSWER-0.001 ft center of gravity change
triggers TCTO.

Changes to hull structure, space allocation, watertight integrity or compartmentation
require - ANSWER-TCTO

Change to any system that affects spare parts allowance require - ANSWER-TCTO

Fluid or Paint System Changes require - ANSWER-TCTO

Changes that require Electromagnetic Compatibility EMC or TEMPEST Inspection
require - ANSWER-TCTO

Form fit or function changes require - ANSWER-TCTO

Changes in software MODS require - ANSWER-TCTO

All cutter and boats operating machine machinery, Shelby inspected how often -
ANSWER-Every hour and reading shall be recorded

How often do cutters equipped with video and electronic control systems that monitor
space is for fire and flooding need to be inspected - ANSWER-Every 4 hours

How often should machine machinery be checked in port? - ANSWER-Every four hours

,How often should Electrical short ties be inspected? - ANSWER-During the hours of 6
AM to 10 PM

All propulsion machinery shall be attended during - ANSWER-Main engine start, warm
up, securing, and during other than normal operating conditions

Coast Guard requires certified welding, brazing, and non-destructive task procedures to
- ANSWER-Provide standard across Coast Guard, ensure high-quality welds, provide
an adequate level of safety, develop a valid method to measure knowledge and skill,
provide consistent requirements between organic commercial service providers

All critical welds must be welded by a blank and inspected at a minimum by a blank -
ANSWER-Certified Coast Guard welder
Level two non-destructive test qualified INSPECTOR

What is the safety and environmental health manual? - ANSWER-COMDINST space
M5100.47

Do not itemize fuel when using it as a what - ANSWER-Solvent

PD 680, type two flashpoint 140 F and biotech HI SOLV space are available from where
- ANSWER-NSS

Never use what as a solvent - ANSWER-Gas

What is considered a hot surface for fuel? - ANSWER-400°

What is a hot surface for lube or hydraulic oil? - ANSWER-650°

What is the reference temperature for insulated surfaces - ANSWER-The temperature
under the insulation

Coast Guard to float gas, free engineers are not authorized to certified spaces as gas
free for blank - ANSWER-Commercial contract work

Coast Guard, afloat, gas, free engineers, a float, gas, free engineer, petty officers that
have obtained and maintained qualifications are authorized to certify spaces for work
only for who - ANSWER-Coast Guard civilian and DOD persons

EPO must issue how many gas free engine engineering certificates per year to keep
qualifications current - ANSWER-Four

What is alternative maintenance? - ANSWER-Changes to equipment or systems that
change the design or design capabilities to improve inherent, reliability, or functionality

What is availability? - ANSWER-The percent of time that a system is ready for use

, What is corrective maintenance? - ANSWER-Maintenance required to restore operation
of systems and equipment to design parameters when functional failure has occurred

What is inherent availability? - ANSWER-The percent of time that a system is
theoretically available for use

What is functional failure? - ANSWER-Failure of an item to perform normal of
characteristic actions within specified limits

What is maintenance manager? - ANSWER-Any person responsible for managing
alternative, preventative, or corrective maintenance

What is operational availability? - ANSWER-Percent of time operational system is ready
for use

What is preventative maintenance? - ANSWER-Actions taken to minimize conditions
that causes unacceptable degradation of functions, prior to the occurrence of actual
failure

EAL unscheduled maintenance - ANSWER-AMMIS supply management, ACS
configuration management

Unscheduled maintenance without MPC's are documented where - ANSWER-EAL

What does SFLC use to identify trends and potential reliability deficiencies - ANSWER-
Supply and demand rates/failure data

What is FRACAS - ANSWER-Failure reporting and corrective action system

What is a time directed task? - ANSWER-Life renewal, regardless of condition

A blank fault safety shorting probe shall be conspicuously located in all engineering
spaces containing switch boards or other installed high-voltage electrical equipment -
ANSWER-25,000 V

What is a normal operating station? - ANSWER-The place where the watch stands or
the position from which he or she shifts duplex strainers

NSTM chapter 635 provides guidance on what - ANSWER-Piping insulation and
protective covers

What must shields be made of? - ANSWER-Sheet metal, or three layers of aluminized
glass cloth secured withdrawals string

Document information

Uploaded on
May 14, 2025
Number of pages
20
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$20.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
NursingTutor1
3.9
(460)
Sold
1703
Followers
1073
Items
18454
Last sold
2 days ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions