What is the maximum pressure to be placed on a FRP tank during a pre-installation test? A. 3 pounds B. 10 pounds C. 50 pounds D. 15 pounds - ACCURATE ANSWERS A. 3 pounds In absence of local requirements, the recommended minimum distance between a tank excavation and adjacent structures or property lines? A. 10 feet. B. 50 feet C. 2 feet D. 5 feet - ACCURATE ANSWERS D. 5 feet According to FRP tank manufactures' specifications, the burial depth for an FRP tank should not exceed? A. 2 feet B. 12 feet C. 7 feet D. 4 feet - ACCURATE ANSWERS C. 7 feet Industry codes, as well as the specification of individual manufactures, do not entirely agree as to the minimum space that should be maintained between tanks in stable soil conditions. Listed below are ranges of minimum spacing between tanks, derived from various industry codes and manufactures specifications. which range is most accurate? A. From 30 to 40 inches. B. From 12 to 24 inches. C. From 6 to 10 inches. D. From 36 to 48 inches. - ACCURATE ANSWERS B. From 12 to 24 inches. When installing a steel tank which has zinc anodes welded directly onto the tank for cathodic protection, you should? A. Take care not to touch the anodes, in order to avoid danger of electrical shoc

Content preview

UST TEST PREP QUESTIONS |
REVISION MATERIALS 2025|26 |
GUARANTEED ACCURATE
ANSWERS |VERIFIED |LATEST
VERSION

What is the maximum pressure to be placed on a FRP tank during a pre-
installation test?
A. 3 pounds
B. 10 pounds
C. 50 pounds
D. 15 pounds - ACCURATE ANSWERS✔✔ A. 3 pounds


In absence of local requirements, the recommended minimum distance
between a tank excavation and adjacent structures or property lines?
A. 10 feet.
B. 50 feet
C. 2 feet
D. 5 feet - ACCURATE ANSWERS✔✔ D. 5 feet


According to FRP tank manufactures' specifications, the burial depth for
an FRP tank should not exceed?

,A. 2 feet
B. 12 feet
C. 7 feet
D. 4 feet - ACCURATE ANSWERS✔✔ C. 7 feet


Industry codes, as well as the specification of individual manufactures,
do not entirely agree as to the minimum space that should be maintained
between tanks in stable soil conditions. Listed below are ranges of
minimum spacing between tanks, derived from various industry codes
and manufactures specifications. which range is most accurate?
A. From 30 to 40 inches.
B. From 12 to 24 inches.
C. From 6 to 10 inches.
D. From 36 to 48 inches. - ACCURATE ANSWERS✔✔ B. From 12 to
24 inches.


When installing a steel tank which has zinc anodes welded directly onto
the tank for cathodic protection, you should?
A. Take care not to touch the anodes, in order to avoid danger of
electrical shock.
B. Securely wrap the anodes in plastic, so they will remain dry after
installation, regardless of depth of the water table.
C. Connect each of the anodes to all others with an insulated wire.


EXAMLINKS
STUDY SMART,

, D. Remove the plastic wrappings around the anodes prior to installation.
- ACCURATE ANSWERS✔✔ D. Remove the plastic wrappings around
the anodes prior to installation.


If local authorities and tank manufactures permit a sand slurry mixture
to be used for backfilling a tank, what steps should be taken to insure
that use of the slurry is proper?
A. Use only personnel trained in the sand slurry method by the tank
manufacturer, and use the method only with the manufacturer's prior
approval.
B. Combine the sand slurry mixture with two parts of crushed stone.
C. Use salt water in preparing the slurry mixture.
D. Pump the slurry mixture into the excavation through a 1/2 inch hose.
- ACCURATE ANSWERS✔✔ A. Use only personnel trained in the sand
slurry method by the tank manufacturer, and use the method only with
the manufacturer's prior approval.


What is the minimum depth of bedding required for a pipe trench in
traffic areas?
A. 12 inches.
B. 6 inches.
C. 2 inches.
D. 18 inches. - ACCURATE ANSWERS✔✔ B. 6 inches.



EXAMLINKS
STUDY SMART,

Document information

Uploaded on
May 8, 2025
Number of pages
30
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$19.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
EXAMLINKS
3.1
(17)
Sold
65
Followers
6
Items
3522
Last sold
4 weeks ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions