with the condensing pressure and compressor speed remaining constant, a decrease in suction pressure will cause a(n): a. Decrease in compressor capacity and decrease in current. b. Increase in compressor capacity and decrease in current. c. Increase in compressor capacity and increase in current. d. Decrease in compressor capacity and increase in current. - ANSWERD An indication of non-condensable gas in a refrigeration system is significantly: a. Lower-than-normal suction pressures. b. higher-than-normal suction pressures. c. Lower-than-normal head pressures. d. higher-than-normal head pressures. - ANSWERD A transformer rated at 40 VA at 24 volts output has a maximum capacity of: a. 0.625 A. b. 0.960 A. c. 1.240 A. d. 1.667 A. - ANSWERD Using the illustration below, what is the pressure drop across the refrigerant distributor and distributor tubes?

Content preview

NATE INDUSTRY COMPETENCY EXAM:
COMMERCIAL REFRIGERATION
QUESTIONS & ANSWERS 100% SOLVED

with the condensing pressure and compressor speed remaining constant, a decrease in
suction pressure will cause a(n):

a. Decrease in compressor capacity and decrease in current.
b. Increase in compressor capacity and decrease in current.
c. Increase in compressor capacity and increase in current.
d. Decrease in compressor capacity and increase in current. - ANSWERD

An indication of non-condensable gas in a refrigeration system is significantly:

a. Lower-than-normal suction pressures.
b. higher-than-normal suction pressures.
c. Lower-than-normal head pressures.
d. higher-than-normal head pressures. - ANSWERD

A transformer rated at 40 VA at 24 volts output has a maximum capacity of:

a. 0.625 A.
b. 0.960 A.
c. 1.240 A.
d. 1.667 A. - ANSWERD

Using the illustration below, what is the pressure drop across the refrigerant distributor
and distributor tubes?

a. 2.5 psi.
b. 35 psi.
c. 71 psi.
d. 120 psi. - ANSWERB

The current that opens the contacts in the current relay is the:

a. Start-winding current.
b. Run-winding current.
c. 24-volt applied voltage.

,d. Back EMF. - ANSWERD

A unit cooler is inspected and found to be completely iced up. The heaters and defrost
timer are found to be working properly. A technician should:

a. Adjust the defrost termination switch to a higher temperature setting.
b. Adjust the thermostatic expansion valve to a higher superheat setting.
c. Clear all of the ice from the coil and find out why the coil is frosted.
d. Increase the frequency of the defrost cycle. - ANSWERA

what is the correct gauge pressure corresponding to an absolute pressure of 24.7 psia
at sea level?

a. 10 psig.
b. 12.6 psig.
c. 39.4 psig.
d. 39.7 psig. - ANSWERA

For a lineup of medium temperature case, an evaporator temperature 0f 23°F is
needed. The following conditions exist:
· The suction line pressure drop is equivalent to approximately 2°F.
· The liquid line pressure drop is equivalent to 1°F.
The compressor capacity should be selected based on a saturated suction temperature
of:

a. 20°F.
b. 21°F.
c. 23°F.
d. 25°F. - ANSWERB

What is true of systems with multiple evaporators at different temperatures?

a. It is required to install evaporator pressure regulator(s).
b. The compressor discharge pressure will be a function of the coldest space.
c. It is required to install a head pressure control valve.
d. It is required to install a crankcase pressure regulator. - ANSWERA

If charging a system by subcooling, what metering devices is installed?

a. Capillary tube.
b. Restrictor.
c. Thermostatic expansion valve.
d. Fixed orifice. - ANSWERC

The most critical refrigerant line with respect to sizing for compressor performance is
the:

, a. Liquid line.
b. Discharge line.
c. Suction line.
d. Bypass line. - ANSWERC

In a liquid line, excess pressure drop can cause:

a. Sweating suction lines.
b. Flash gas.
c. Compressor overload.
d. Liquid subcooling. - ANSWERB

What are the two factors making up the safety classification for refrigerants?

a. Toxicity and time weighted average.
b. Toxicity and flammability.
c. Emergency exposure limit and time weighted average.
d. Flammability and TEWI. - ANSWERB

What would be most affected by the use of an oversized suction line?

a. Discharge temperature.
b. Oil return.
c. Return gas temperature.
d. Refrigerant migration. - ANSWERB

On an electrical diagram, the below symbol represents a control that:

a. Closes on pressure rise.
b. Opens on pressure rise.
c. Closes on temperature fall.
d. Opens on temperature rise. - ANSWERB

During the pulldown periods of single compressor condensing units, compressor
overloading can best be prevented by using a(n):

a. Thermostatic expansion valve.
b. Evaporator pressure regulating valve.
c. Crankcase pressure regulating valve.
d. Head pressure valve. - ANSWERC

The purpose of a crankcase heater is to:

a. Reduce refrigerant migration into the oil during the off cycle.
b. Minimize refrigerant flooding into the compressor.

Document information

Uploaded on
May 8, 2025
Number of pages
18
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$17.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
nursingismylife
3.6
(38)
Sold
265
Followers
174
Items
9114
Last sold
4 weeks ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions