RESIDENTIAL ELECTRICAL INSPECTOR EXAM |QUESTIONS
WITH CORRECT DETAILED ANSWERS




Electrical devices operating at less than ___ volts and not supplying more than ___
watts of energy shall be exempt from requiring an electrical permit. - ANSWER-25,50


Section R105.2 Electrical #4


Who has the authority to give permission to provide temporary power? - ANSWER-
Building Official


Section R107.3


An approved enclosure shall be used to guard people against accidental contact with
energized parts that operate at a minimum of ______ volts. - ANSWER-50


Section E3404.9

,A ______ conductor is a conductor that is encased within a material or has a
thickness NOT recognized by the IRC as electrical insulation. - ANSWER-Covered


Definitions Section E3501 - Conductor, Covered



When splicing, terminating, or connecting a conductor to a fixture or device the
minimum length of free conductor required at an outlet, junction box, or switch point
shall be at least ____ inches? - ANSWER-6


Section E3406.11.3


Electrical copper conductors used for feeders and branch circuits shall have a
minimum size of ______. - ANSWER-No. 14 AWG


Section E3406.3


An overhead service conductor spanning over a driveway shall maintain a minimum
vertical clearance of ____ feet from final grade. - ANSWER-12


Section E3604.2.2 #2


The mounting supports used to support service-entrance cables shall be located
within ____ inches of the service head and at intervals no greater than ____ inches. -
ANSWER-12,30


Section E3605.7

, A minimum clearance not less than ____ feet shall be provided between the side of a
door and an open service conductor without an overall outer jacket. - ANSWER-3


Section E3604.1


An open service conductor shall have a minimum vertical clearance of no less than
___ feet above a roof that has a 5:12 roof slope. - ANSWER-3


Section E3604.2.1 Exception 2


True or False. The disconnecting means for an electrical service cannot be installed
in a bathroom. - ANSWER-True


Section E3601.6.2


A metal underground water pipe must be in direct contact with the earth for a
minimum of ___ feet to be considered as a grounding electrode. - ANSWER-10


Section E3608.1.1


A ground ring can be used as a grounding electrode if located a minimum ___ inches
below the earth and at least ___ feet of bare copper wire no smaller than ___ AWG is
used. - ANSWER-30, 20, 2


Section E3608.1.3


Two grounding rods used in one grounding electrode system must be located at least
___ feet apart. - ANSWER-6

Document information

Uploaded on
May 4, 2025
Number of pages
25
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$11.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
NurseShanit
5.0
(275)
Sold
19
Followers
8
Items
488
Last sold
3 months ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions