2025 LATEST RHODE ISLAND JOURNEYMAN/MASTER
PLUMBER EXAM. COMPLETE TEST BANK WITH
ACTUAL QUESTIONS AND CORRECT VERIFIED
ANSWERS. GUARANTEED EXAM EXCLLENCE
State of Rhode Island Plumbing Code is known as:
Plumbing Code Regulation SBC-3
Water Services Shall Be Installed Not Less Than:
4' 6" Below Grade
Piping installed in exterior walls or areas subject to freezing must:
Insulated/Heated or Both
Building Sewers connected to a public sewer shall have a minimum coverage of:
36" Below Grade
A safe waste pan shall be installed
Under a water heater 6 gallons or greater that is elevated
,A safe waste pan shall be at least
2" deep with 2" clearance around heater
Water service piping and building drain/sewer shall be separated by:
10' undisturbed compacted earth
Water service separation distance is not required if:
Water line is installed minimum 12" above sewer line at highest point
Distance for a septic tank/sewer to a private water supply(well) is:
50'
Where frost closure is common an increase in vent size shall take place:
6"below the roof with an approved fitting
High Hazard flood zone is:
"V" zone (subject to wave heights in excess of 3')
,Lead free pipe and fittings contain less than:
8.0% Lead
Hot water is water at temperature greater than or equal to:
110 degrees
Lead free solder and flux contain no more than
0.2% Lead
Strainer plates on drain lines for rodent proofing must have openings:
0.5 inches
Sleeves for pipes passing through foundation walls or under footings shall be:
Two pipe size greater than the pipe passing through it
Travel distance to toilet facilities in merchantile/occupancies are:
500'
, Travel distance to toilet facilities in covered malls are:
300'
Water closets, bidets or lavatories shall have a clearance from center of fixture to
wall of:
15"
The required clearance from front of fixture to a wall, door or other fixture is:
21"
Minimum size floor drains for public laundries or central washing facilities is:
3"
Shower waste outlets shall be minimum of:
1 1/2"
Minimum size removable strainer for shower compartments are:
3"
PLUMBER EXAM. COMPLETE TEST BANK WITH
ACTUAL QUESTIONS AND CORRECT VERIFIED
ANSWERS. GUARANTEED EXAM EXCLLENCE
State of Rhode Island Plumbing Code is known as:
Plumbing Code Regulation SBC-3
Water Services Shall Be Installed Not Less Than:
4' 6" Below Grade
Piping installed in exterior walls or areas subject to freezing must:
Insulated/Heated or Both
Building Sewers connected to a public sewer shall have a minimum coverage of:
36" Below Grade
A safe waste pan shall be installed
Under a water heater 6 gallons or greater that is elevated
,A safe waste pan shall be at least
2" deep with 2" clearance around heater
Water service piping and building drain/sewer shall be separated by:
10' undisturbed compacted earth
Water service separation distance is not required if:
Water line is installed minimum 12" above sewer line at highest point
Distance for a septic tank/sewer to a private water supply(well) is:
50'
Where frost closure is common an increase in vent size shall take place:
6"below the roof with an approved fitting
High Hazard flood zone is:
"V" zone (subject to wave heights in excess of 3')
,Lead free pipe and fittings contain less than:
8.0% Lead
Hot water is water at temperature greater than or equal to:
110 degrees
Lead free solder and flux contain no more than
0.2% Lead
Strainer plates on drain lines for rodent proofing must have openings:
0.5 inches
Sleeves for pipes passing through foundation walls or under footings shall be:
Two pipe size greater than the pipe passing through it
Travel distance to toilet facilities in merchantile/occupancies are:
500'
, Travel distance to toilet facilities in covered malls are:
300'
Water closets, bidets or lavatories shall have a clearance from center of fixture to
wall of:
15"
The required clearance from front of fixture to a wall, door or other fixture is:
21"
Minimum size floor drains for public laundries or central washing facilities is:
3"
Shower waste outlets shall be minimum of:
1 1/2"
Minimum size removable strainer for shower compartments are:
3"