BICSI TECHNICIAN EXAM LATEST QUESTIONS WITH 100% CORRECT ANSWERS

Rating
-
Sold
-
Pages
6
Grade
A+
Uploaded on
29-04-2025
Written in
2024/2025

Residential - ANSWER -570 Data Centers - ANSWER -942 Class 1 - ANSWER -Single building with one equipment room Class 2 - ANSWER -Single building with multiple telecom spaces Class 3 - ANSWER -Multiple buildings on a single campus Class 4 - ANSWER -Multiple sites with multiple buildings Labels - ANSWER -Consist of face stock material Tags - ANSWER -Attached to the mounting surface Electronic identifieres - ANSWER -Prevent potential intruders from identifying the location of key components What is the minimum bend radius for a 50 mm (2in) conduit? - ANSWER -12 inches When installing optical fiber, consider placing three innerducts in a 103mm (4 trade size) conduit with the following sizes: - ANSWER -two 38 mm (1.5in), one 25mm (1in) Open top cable supports should be installed to provide a minimum of ________________ clearance above ceilings - ANSWER -3 inches PBB - ANSWER -dedicated extension of the building ac grounding (earthing) electrode system for the telecom bonding infrastructures TBC - ANSWER -bonds the electrical systems grounding (earthing) electrode system to the PBB TBB - ANSWER -interconnects the PBB to the SBB BBC - ANSWER -used to equalize potentials between SBBs on the same floor of a structure. Which is better for an "L" rating? High or Low Numbers - ANSWER -Low F rating- how many hours - ANSWER -1-4 Hrs T rating- how many hours - ANSWER -0-3 Hrs Electric motors and transformers - ANSWER -48" Fluorescent Lamps - ANSWER -6" Arc Welders - ANSWER -31.5" Frequency Induction Heating - ANSWER -39" Which OLTS testing method stimulates the loss of two mated pairs and an

Show more Read less
Institution
BICSI TECHNICIAN 2
Course
BICSI TECHNICIAN 2









Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
BICSI TECHNICIAN 2
Course
BICSI TECHNICIAN 2

Document information

Uploaded on
April 29, 2025
Number of pages
6
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

BICSI TECHNICIAN EXAM LATEST QUESTIONS WITH
100% CORRECT ANSWERS


Residential - ANSWER -570

Data Centers - ANSWER -942

Class 1 - ANSWER -Single building with one equipment room

Class 2 - ANSWER -Single building with multiple telecom spaces

Class 3 - ANSWER -Multiple buildings on a single campus

Class 4 - ANSWER -Multiple sites with multiple buildings

Labels - ANSWER -Consist of face stock material

Tags - ANSWER -Attached to the mounting surface

Electronic identifieres - ANSWER -Prevent potential intruders from identifying
the location of key components

What is the minimum bend radius for a 50 mm (2in) conduit? - ANSWER -12
inches

When installing optical fiber, consider placing three innerducts in a 103mm (4 trade
size) conduit with the following sizes: - ANSWER -two 38 mm (1.5in), one 25mm
(1in)

Open top cable supports should be installed to provide a minimum of
________________ clearance above ceilings - ANSWER -3 inches

PBB - ANSWER -dedicated extension of the building ac grounding (earthing)

, electrode system for the telecom bonding infrastructures
TBC - ANSWER -bonds the electrical systems grounding (earthing) electrode
system to the PBB

TBB - ANSWER -interconnects the PBB to the SBB

BBC - ANSWER -used to equalize potentials between SBBs on the same floor of
a structure.

Which is better for an "L" rating? High or Low Numbers - ANSWER -Low

F rating- how many hours - ANSWER -1-4 Hrs

T rating- how many hours - ANSWER -0-3 Hrs

Electric motors and transformers - ANSWER -48"

Fluorescent Lamps - ANSWER -6"

Arc Welders - ANSWER -31.5"

Frequency Induction Heating - ANSWER -39"

Which OLTS testing method stimulates the loss of two mated pairs and an
installed optical fiber link? - ANSWER -One jumper method

What can cause a gain splice on an OTDR trace? - ANSWER -Mismatch in the
fibers
L Rating - ANSWER -A firestops ability to provide a smoke stop. (air leakage
rate)

To avoid damaging cable jacket, how often must you securely fasten electrical
nonmetallic tubing (ENT) - ANSWER -3 Feet so it does not damage the cable What
$10.99
Get access to the full document:

100% satisfaction guarantee
Immediately available after payment
Both online and in PDF
No strings attached

Get to know the seller
Seller avatar
rachaelmumbi

Get to know the seller

Seller avatar
rachaelmumbi Teachme2-tutor
View profile
Follow You need to be logged in order to follow users or courses
Sold
0
Member since
9 months
Number of followers
0
Documents
53
Last sold
-

0.0

0 reviews

5
0
4
0
3
0
2
0
1
0

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions