Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Document preview thumbnail
Preview 3 out of 16 pages
Exam (elaborations)

ASET CNIM Cards Exam Questions with Correct Answers Graded A+

Document preview thumbnail
Preview 3 out of 16 pages

ASET CNIM Cards Exam Questions with Correct Answers Graded A+ Which nerve should be stimulated for lower limb SSEP as recommended by American Clinical Neurophysiology Society guidelines for short-latency SSEP? - Answers Posterior Tibial Nerve Which nerve should be stimulated for upper limb SSEP as recommended by American Clinical Neurophysiology Society guidelines for short-latency SSEP? - Answers Median Nerve The active electrode is usually placed on the scalp 2cm behind _____ for lower limb SSEP - Answers Vertex (at Cz') The warning criteria for SSEP changes have been generally accepted as - Answers 50% decrease in amplitude and 10% increase in latency Electrode placement on the scalp is based on - Answers 10-20 System Central Conduction Time (CCT) for median nerve is calculated between which peaks? - Answers P14-N20 Peripheral Conduction Time (PCT) for median nerve is calculated between which peaks? - Answers EP-P14 Central Conduction Time (CCT) for posterior tibial nerve is calculated between which peaks? - Answers LP-P37 Peripheral Conduction Time (PCT) for posterior tibial nerve is calculated between which peaks? - Answers PF-LP Peripheral response (PF) to the first response from cord (LP) SSEP is not recordable when cerebral perfusion drops below: - Answers 15cc/min/100 grams of tissue The normal amplitude of SSEP responses recorded from scalp is approximately: - Answers 0.1 microV to 10 microV If there is a sudden loss of ipsilateral Erb's point and contralateral N20 response, what is the first step for troubleshooting? - Answers Check arm positioning Latency and/or amplitude changes in SSEP responses can result from: - Answers Anesthesia, Hypothermia, Surgical manipulation, Technical failure The N20 response is generated from which structure? - Answers Somatosensory cortex (contralateral to the stimulation side) The P14 response is generated from which structure? - Answers Caudal medial lemniscus The N34 subcortical response is a near-field or far-field response? - Answers far-field response Lumbar potential (LP) is a stationary (non-propagated) potential -true -false - Answers True The most reliable criteria for SSEP abnormality is: - Answers Absence of the obligatory waveforms Prolongation of the interpeak latencies The N18 subcortical response is a near-field or far-field response? - Answers Far-field response After stimulation of the median nerve at the wrist, the response recorded at the Erb's point consists of: - Answers An orthodromic sensory and antidromic motor action potentials Obligatory waves of the posterior tibial nerve (PTN) are: - Answers PF, LP, P31, N34, P37 Obligatory waves of the median nerve (MN) are: - Answers N9, N13, P14, N18, N20 What is the location of injury if there is a loss of cortical SSEP responses but intact Erb's point responses? - Answers Brainstem / Thalamus Which of the following sensations are not transferred via dorsal column? -proprioception -stereognosis -temperature - Answers temperature What is the blood supply of cortical responses elicited by median nerve stimulation? - Answers Middle Cerebral Artery (MCA) Ohm's law is mathematically expressed as: - V=I/R - V=IR - I=VR - R=VI - Answers V=IR Good insulating materials that inhibit the current flow are: - Answers Glass, rubber, wood What is the maximum allowable chassis leakage current? - Answers Should be less than 300microA rms with ground open What is the maximum allowable leakage current through patient leads to ground with 120VAC applied? - Answers 10microA rms In order to minimize filter-induced phase shift, the ratio of high-to-low frequency filter should be at least? - Answers 100:1 A large current passing from an external surface to another is known as: - Answers Macroshock A very low current as small as 10 microvolts that can be lethal to the patient if it passes through the heart is known as: - Answers Microshock A band-stop filter is also called: - Answers 60Hz notch filter What is the electrical line frequency in the operating rooms in the USA? - Answers 60Hz The inter stimulus interval (ISI) of a 40Hz stimulation will be: - Answers 25 milliseconds Unequal electrode impedances may result in: - Answers increased noise The electrical charge stored by a capacitor is known as: - Answers capacitanc

Content preview

ASET CNIM Cards Exam Questions with Correct Answers Graded A+

Which nerve should be stimulated for lower limb SSEP as recommended by American Clinical
Neurophysiology Society guidelines for short-latency SSEP? - Answers Posterior Tibial Nerve

Which nerve should be stimulated for upper limb SSEP as recommended by American Clinical
Neurophysiology Society guidelines for short-latency SSEP? - Answers Median Nerve

The active electrode is usually placed on the scalp 2cm behind _____ for lower limb SSEP - Answers
Vertex (at Cz')

The warning criteria for SSEP changes have been generally accepted as - Answers 50% decrease in
amplitude and 10% increase in latency

Electrode placement on the scalp is based on - Answers 10-20 System

Central Conduction Time (CCT) for median nerve is calculated between which peaks? - Answers P14-N20

Peripheral Conduction Time (PCT) for median nerve is calculated between which peaks? - Answers EP-
P14

Central Conduction Time (CCT) for posterior tibial nerve is calculated between which peaks? - Answers
LP-P37

Peripheral Conduction Time (PCT) for posterior tibial nerve is calculated between which peaks? -
Answers PF-LP

Peripheral response (PF) to the first response from cord (LP)

SSEP is not recordable when cerebral perfusion drops below: - Answers 15cc/min/100 grams of tissue

The normal amplitude of SSEP responses recorded from scalp is approximately: - Answers 0.1 microV to
10 microV

If there is a sudden loss of ipsilateral Erb's point and contralateral N20 response, what is the first step
for troubleshooting? - Answers Check arm positioning

Latency and/or amplitude changes in SSEP responses can result from: - Answers Anesthesia,
Hypothermia, Surgical manipulation, Technical failure

The N20 response is generated from which structure? - Answers Somatosensory cortex (contralateral to
the stimulation side)

The P14 response is generated from which structure? - Answers Caudal medial lemniscus

The N34 subcortical response is a near-field or far-field response? - Answers far-field response

Lumbar potential (LP) is a stationary (non-propagated) potential

,-true

-false - Answers True

The most reliable criteria for SSEP abnormality is: - Answers Absence of the obligatory waveforms

Prolongation of the interpeak latencies

The N18 subcortical response is a near-field or far-field response? - Answers Far-field response

After stimulation of the median nerve at the wrist, the response recorded at the Erb's point consists of: -
Answers An orthodromic sensory and antidromic motor action potentials

Obligatory waves of the posterior tibial nerve (PTN) are: - Answers PF, LP, P31, N34, P37

Obligatory waves of the median nerve (MN) are: - Answers N9, N13, P14, N18, N20

What is the location of injury if there is a loss of cortical SSEP responses but intact Erb's point responses?
- Answers Brainstem / Thalamus

Which of the following sensations are not transferred via dorsal column?

-proprioception

-stereognosis

-temperature - Answers temperature

What is the blood supply of cortical responses elicited by median nerve stimulation? - Answers Middle
Cerebral Artery (MCA)

Ohm's law is mathematically expressed as:

- V=I/R

- V=IR

- I=VR

- R=VI - Answers V=IR

Good insulating materials that inhibit the current flow are: - Answers Glass, rubber, wood

What is the maximum allowable chassis leakage current? - Answers Should be less than 300microA rms
with ground open

What is the maximum allowable leakage current through patient leads to ground with 120VAC applied?
- Answers 10microA rms

, In order to minimize filter-induced phase shift, the ratio of high-to-low frequency filter should be at
least? - Answers 100:1

A large current passing from an external surface to another is known as: - Answers Macroshock

A very low current as small as 10 microvolts that can be lethal to the patient if it passes through the
heart is known as: - Answers Microshock

A band-stop filter is also called: - Answers 60Hz notch filter

What is the electrical line frequency in the operating rooms in the USA? - Answers 60Hz

The inter stimulus interval (ISI) of a 40Hz stimulation will be: - Answers 25 milliseconds

Unequal electrode impedances may result in: - Answers increased noise

The electrical charge stored by a capacitor is known as: - Answers capacitance

Opposition to change in current flow is known as: - Answers Inductance

Subdermal electrodes made of platinum have what advantage? - Answers inert stability during
stimulation and MRI compatible

The impedances of subdermal needle electrodes are typically higher than scalp electrodes

-True

-False - Answers True

Where is the best place to put a ground electrode in order to reduce any stimulation artifact? - Answers
Between stimulation and recording electrodes

The cortical grid is made of what type of metal? - Answers Platinum

What is the electrical line frequency in the operating rooms in Europe? - Answers 50Hz

Electrocochleogram (ECochG) consists of combinations of which responses? - Answers Cochlear
microphonic (CM), Summating Potentials (SP), and Auditory nerve compound action potentials

Click stimulations should be delivered unilaterally or bilaterally? - Answers unilaterally

What is the recommended bandpass filter settings for BAEP recordings? - Answers 10-30Hz to 2500-
3000Hz

The filter roll-off for BAEP should not exceed what values for low and high frequency filters? - Answers
12bB/octave for low frequency filter

24dB/octave for high frequency filter

Document information

Uploaded on
April 23, 2025
Number of pages
16
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$10.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
TutorJosh
3.5
(76)
Sold
495
Followers
16
Items
32839
Last sold
1 day ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions