To pass a Certification Test, a 1000 gpm pumper must deliver: a) 1000 gpm at 200 psi for two hours b) 700 gpm at 200 psi for one-half hour c) 500 gpm at 150 psi for one-half hour d) 500 gpm at 150 psi for two hours - CORRECT ANSWER-b) 700 gpm at 200 psi for one-half hour The test of an engine pump which is done by the Fire Department is known as: a) the certification test b) the hydrostatic test c) the service test d) the manufacture's test - CORRECT ANSWER-c) the service test The auxiliary cooling system on a pump: a) acts as a heat exchanger b) cools the pump directly c) cools the engine by changing engine coolant with pump water d) uses ram air to keep the engine cool - CORRECT ANSWER-a) acts as a heat exchanger If you are pumping into a standpipe to a fire on the 10th floor, how many pounds must you provide to overcome the back pressure? a) 25 psi b) 45 psi c) 70 psi d) 75 psi - CORRECT ANSWER-b) 45 psi The driving test which tests the ability to travel in a straight line is: a) the straight line test b) the serpentine test c) the diminishing clearance test d) the alley dock test - CORRECT ANSWER-c) the diminishing clearance test

Aperçu du contenu

FAE Questions ILLINOIS Latest Update
With Complete Solutions
To pass a Certification Test, a 1000 gpm pumper must deliver:
a) 1000 gpm at 200 psi for two hours
b) 700 gpm at 200 psi for one-half hour
c) 500 gpm at 150 psi for one-half hour
d) 500 gpm at 150 psi for two hours - CORRECT ANSWER-b) 700 gpm at 200 psi for
one-half hour

The test of an engine pump which is done by the Fire Department is known as:
a) the certification test
b) the hydrostatic test
c) the service test
d) the manufacture's test - CORRECT ANSWER-c) the service test

The auxiliary cooling system on a pump:
a) acts as a heat exchanger
b) cools the pump directly
c) cools the engine by changing engine coolant with pump water
d) uses ram air to keep the engine cool - CORRECT ANSWER-a) acts as a heat
exchanger

If you are pumping into a standpipe to a fire on the 10th floor, how many pounds must
you provide to overcome the back pressure?
a) 25 psi
b) 45 psi
c) 70 psi
d) 75 psi - CORRECT ANSWER-b) 45 psi

The driving test which tests the ability to travel in a straight line is:
a) the straight line test
b) the serpentine test
c) the diminishing clearance test
d) the alley dock test - CORRECT ANSWER-c) the diminishing clearance test


The name of the gauge which shows the incoming pressure to a pump:
a) Pilot Gauge
b) Bourden Gauge
c) Compound Gauge
d) Combination Gauge - CORRECT ANSWER-c) Compound Gauge

, If the pump sounds like stones are rattling around inside, it is most likely that the pump:
a) is in cavitation
b) does not have sufficient lubrication
c) has a loose pump packing
d) is overheating - CORRECT ANSWER-a) is in cavitation

The Fire apparatus driver/operator is responsible for all the following except:
a) Safe transportation of firefighters.
b) Mechanical and Electrical repairs on the apparatus
c) Operating the apparatus properly and swiftly.
d) Ensuring readiness of the equipment on the apparatus. - CORRECT ANSWER-b)
Mechanical and Electrical repairs on the apparatus

Because of the critical time factor and nature of fire, a fire apparatus is one of the few
emergency vehicles that is not required to stop for school buses disembarking or
boarding children; it is required that the vehicle slow to maximum speed of 20 MPH
through the zone.
a) True
b) False - CORRECT ANSWER-b) False

Atmospheric pressure plays an important role for the pump operator when:
a) working from a hydrant
b) working in a relay operation
c) working from a positive pressure source
d) working from draft - CORRECT ANSWER-d) Working from Draft

The Pressure at the base of a column of water is based on:
a) The Weight of the water
b) The atmospheric pressure
c) The diameter of the column
d) The temperature of the water - CORRECT ANSWER-a)The Weight of the water

The change from pressure mode to volume mode should be made:
a) When the pump Must deliver more than 25% of its rated capacity
b) When the pump must deliver more than 50% of its rated capacity
c) When the pump must deliver more than 75% of its rated capacity
d) When the pump must deliver more than 100% of its rated capacity - CORRECT
ANSWER-b)When the pump must deliver more than 50% of its rated capacity

What is the total work done by the pump to get water into, through and out of the pump?
a) Static Pressure
b) Residual Pressure
c) Net Pump Pressure
d) Compound Pressure - CORRECT ANSWER-c)Net Pump Pressure

Infos sur le Document

Publié le
18 avril 2025
Nombre de pages
12
Écrit en
2024/2025
Type
Examen
Contenu
Questions et réponses
$9.99

Mauvais document ? Échangez-le gratuitement Dans les 14 jours suivant votre achat et avant le téléchargement, vous pouvez choisir un autre document. Vous pouvez simplement dépenser le montant à nouveau.
Rédigé par des étudiants ayant réussi
Disponible immédiatement après paiement
Lire en ligne ou en PDF

Seller avatar
quizletquizizzy
5.0
(1)
Vendu
9
Abonnés
0
Éléments
517
Dernière vente
6 mois de cela



Pourquoi les étudiants choisissent Stuvia

Créé par d'autres étudiants, vérifié par les avis

Une qualité sur laquelle compter : rédigé par des étudiants qui ont réussi et évalué par d'autres qui ont utilisé ce document.

Le document ne convient pas ? Choisis un autre document

Aucun souci ! Tu peux sélectionner directement un autre document qui correspond mieux à ce que tu cherches.

Paye comme tu veux, apprends aussitôt

Aucun abonnement, aucun engagement. Paye selon tes habitudes par carte de crédit et télécharge ton document PDF instantanément.

Student with book image

“Acheté, téléchargé et réussi. C'est aussi simple que ça.”

Alisha Student

Vous travaillez sur vos références ?

Créez des citations précises en APA, MLA et Harvard avec notre générateur de sources gratuit.

Vous travaillez sur vos références ?

Foire aux questions