DAVITA RN EXAM SAMPLE TEST 2025/2026 QUESTIONS
WITH ANSWERS GRADED A+
✔✔Monitor weight and blood pressure - ✔✔Keep a little extra fluid on the patient so it is
available to the kidneys when they start filtering/ ultra filtering on their own

✔✔AKI patients are at increased risk of.... - ✔✔Hypovolemia and hypotension

✔✔What is the proportion of dialysate used at Davita? - ✔✔45X
(Mixture of specific proportions of acid, bicarbonate and dialysis quality water)

✔✔2 most frequent physician prescribed potassium strengths of dialysate concentrate
used at Davita? - ✔✔- 2.0 K+
- 3.0 K+

✔✔Which part of the kidney functions similarly to the dialyzer's semi-permeable
membrane to provide filtration and removal of fluid and toxins? - ✔✔Glomerulus

✔✔What are the 2 waste products removed by dialysis that we monitor with monthly
labs? - ✔✔>blood urea nitrogen (BUN)
> creatinine

✔✔How often are dialysis machine alarm tests performed? - ✔✔Before the initiation of
each patient treatment

✔✔The manual conductivity value - ✔✔>Must match +/- 0.4 mS on the Fresenius
(FMC) 2008K and K2 dialysis delivery system displaced conductivity
>Fresenius 2008T and T BlueStar models don't need to check conductivity
>B Braun machine does not require manual conductivity testing but conductivity must
be verified in the 'ENDLF' machine screen

✔✔What is the safe dialysis pH range? - ✔✔Between 6.9 and 7.6

✔✔Why is it important for patient care teammates to know when the water treatment
system disinfection was performed? - ✔✔Because the end to end disinfection process
will also introduce the disinfectant solution to the dialysis delivery systems through their
water inlet lines.

✔✔Following recirculation, how long can a dialyzer and blood lines be set up? - ✔✔2
hours
(Dialyzer and blood lines are not used for dialysis treatment once recirculating for longer
than 2 hours because of the potential for bacterial growth)

, ✔✔What is the correct procedure for residual bleach testing after the chemical
disinfection of loops and equipment fluid pathways? - ✔✔Residual bleach testing should
be performed
>after each disinfection
>prior to equipment use

✔✔OSHA Vs. CMS infection control requirements - ✔✔OSHA: requires employees to
provide workers with a safe workplace

CMS: concerned with patient care and patient safety

✔✔V-tags - ✔✔State specific regulations to be met within a condition (such as infection
control) providing interpretive guidance for each regulation and citing deficiencies by tag
#

✔✔Hand washing technique when caring for a patient with Clostridioides difficile
infection (C-diff) - ✔✔Soap and water only

✔✔Most common infectious complication in hemodialysis patients - ✔✔Bacterial
vascular access infections

✔✔Organism that causes infection in hemodialysis patients most commonly -
✔✔Methicillin- resistant staphylococcus aureus (MRSA) *viable on surfaces for days

>must pay attention to infection control, proper hand hygiene, cleaning and disinfecting
procedures to prevent the spread of infection (viable on surfaces for days)

✔✔Importance of wearing gloves - ✔✔Reduces the risk of hand contamination and
prevents the transfer of organisms already on hands to a patient.

✔✔Why do you need to perform hand hygiene before and after wearing gloves? -
✔✔Gloves are not impervious and have microscopic pores.

✔✔Who can use clean sinks for hand washing? - ✔✔Teammates and patients

✔✔Is a cleaned dialysis machine considered a 'clean' area? - ✔✔No

✔✔How can you tell if an area or sink is clean or dirty in your facility? - ✔✔It is clearly
labeled with a 'clean' or 'dirty' sign

✔✔What is "strike through" of an external pressure transducer and why is it of concern?
- ✔✔> when fluid could have entered the machine and contaminated the internal
pressure transducer protector providing a reservoir for microorganisms
>causing subsequent patient blood infections

Document information

Uploaded on
April 15, 2025
Number of pages
7
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$11.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
EXAMCAFE
3.5
(42)
Sold
293
Followers
11
Items
36199
Last sold
1 day ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions