CNOR 2024 Zander Notes Questions and Answers Latest 2025/2026 CNOR 2024 Zander Notes Questions and Answers Latest 2025/2026 CNOR 2024 Zander Notes Questions and Answers Latest 2025/2026 CNOR 2024 Zander Notes Questions and Answers Latest 2025/2026 CNOR 2024 Zander Notes Questions and Answers Latest 2025/2026

Content preview

CNOR 2024 Zander Notes Questions and
Answers Latest 2025/2026
Name the 3 Spaulding Classification Systems - CORRECT ANSWERS-Critical
Semi-Critical
Non-Critical

Meaning of Critical Spaulding Classification System - CORRECT ANSWERS-Items
MUST be sterile.
Items will enter -sterile tissue- or -vascular system-

Examples of items in Critical Spaulding Classification System - CORRECT ANSWERS--
Instruments-
-Laparoscopes- -Arthroscopes-
-*Cutting endoscope accessories for biopsy*-
-Cardiac Caths-
-IV caths- - Needles-
-*Urinary Caths-

Meaning of Semi-Critical Spaulding Classification System - CORRECT ANSWERS-
Items SHOULD be sterile.
Items will contact -broken skin- or -MM-

If the manufacturers instructions say it WON'T tolerate sterilization, they CAN be HLD
(but only IF MF SAYS).
-Spores survive HLD-

Examples of items in Semi-Critical Spaulding Classification System - CORRECT
ANSWERS--Bronchoscopes
-GI Scopes/GI endoscopes
-RT equipment (laryngoscope blades)
-Anesthesia equipment

Meaning of Non Critical Spaulding Classification System - CORRECT ANSWERS--Will
be in contact with INTACT SKIN
-Intermediate or Low Level Disinfection or Cleaning.
-Disinfect with an FDA approved disinfectant that's effective against HEP B.

Examples of items in Non Critical Spaulding Classification System - CORRECT
ANSWERS--Furniture
-Laundry/Linens
-OR bed
-BP Cuff/Leads/Monitors/Stethoscopes

,-Tourniquets

Requirement for decontamination area: - CORRECT ANSWERS--Must have a physical
WALL or SEPARATION between decontam and processing areas.
-This includes Immediate Use Areas.
-Why: Because decontam requires NEGATIVE PRESSURE

Sterile Processing Workflow - CORRECT ANSWERS-Decontamination (always 1st) -->
Prep&Pack -->Sterilization
-->Distribute/Store

Most important step to prevent infection: - CORRECT ANSWERS-Cleaning and Pre-
treating with a non-drying enzymatic solution in order to avoid biofilm, which
encapsulates spores.

Decontamination processes - CORRECT ANSWERS--Disassemble everything
-Brush lumens/channels using a brush based on mfr instruction for correct diameter and
length of lumen
-Brush lumens/channels/crevices/joints UNDER WATER
-Automated (washers/ultrasonic) more effective than manual cleaning.

Two Types of Steam Sterilization - CORRECT ANSWERS--Pre-Vac Autoclave/Dynamic
Air Removal
-Gravity Displacement

PreVac settings - CORRECT ANSWERS-270-276

3 min (NON porous instruments/regular instruments)

4 min (POROUS or LUMEN instruments, heavy plastic, rubber, wooden handles, poole
suction)

PreVac/Dynamic Air Removal setting for porous (heavy plastic, rubber, wood handels)
or lumen instruments (poole suction/channels) - CORRECT ANSWERS-270-276 for 4
min

PreVac/Dynamic Air Removal setting for Non Porous instruments - CORRECT
ANSWERS-270-276 for 3 min

How does PreVac/Dynamic Air Removal autoclave work? - CORRECT ANSWERS--
Sucks air out of chamber with a VACCUM then steam is released and snaps down onto
inst/trays.
-DRAINS MUST BE CLEAN
-Most common. Most effective.

Gravity Displacement Autoclave settings - CORRECT ANSWERS-270-276

,3 min: NonPorous/reg instruments

10 min: Porous/Lumens

Gravity Displacement autoclave settings for porous/lumens - CORRECT ANSWERS-
270-276 10 min

Gravity Displacement autoclave settings for NonPorous/reg inst - CORRECT
ANSWERS-270-276 3 min

How does Gravity Displacement autoclave work? - CORRECT ANSWERS-Steam
pushes air down to a thermometer in the drain, the air exits the chamber, drain closes,
cycle starts.

-Not great for trays or packages.

-Rarely used.

Both PreVac/Dynamic Air Removal and Gravity time and temperature requirements are
for the instrument and autoclave only.
For certain containers/systems such as One Tray system or containers with lids: -
CORRECT ANSWERS-I will follow the manufacturers instructions!

3 ways to avoid condensation with steam sterilization items: - CORRECT ANSWERS--
Allow airflow between trays and pkgs and all the way around.
-Remove loads immediately (don't crack the door to cool).
-Don't place items on cooling racks or solid surfaces (can place on lined surfaces).

How many classes of Chemical Integrators? - CORRECT ANSWERS-6

What kind of chemical integrators react to heat? - CORRECT ANSWERS-Class 1
Chemical Indicator
-Reacts to HEAT only. Verifies exposure only.
-Tape-Locks-Filter dots

What kind of chemical integrator is an External Indicator? - CORRECT ANSWERS-
Class 1 Chemical Indicator
External Indicator that reacts to Heat only
-Tape-Locks-Filter dots

What class of Chemical Indicator is the Bowie Dick, and what does it react to? -
CORRECT ANSWERS--Class 2 Chemical Indicator
-Reacts to PRESSURE and ONLY indicates a VACUUM was created.
-Used only with PreVac/Dynamic Air Removal cycles

, What class of chemical indicator measures
-Single Parameter?
-Multi Parameter? - CORRECT ANSWERS--Class 3 Single (Ex: quality of steam)
-Class 4 Multi (Ex: Time+Temp)

-Class 3&4 are usually made by the manufacturer.

Which class of chemical indicator is the most common all inclusive integrator? -
CORRECT ANSWERS-Class 5 Chemical Integrator/Indicator is the
-most common
-covers ALL parameters (time/temp/pressure/steam quality)
-ALL INCLUSIVE
-internal
-placed on each layer and in corner (most challenging area)
-used for implants

Which chemical indicator is used for implants? - CORRECT ANSWERS-Class 5
Integrator

Which class of chemical indicator is used for a particular tray/cycle? - CORRECT
ANSWERS-Class 6 Emulating Integrator
-internal
-all inclusive for a SPECIFIC cycle
-made by mfr for a specific cycle OR tray

What does -integrator- mean? - CORRECT ANSWERS-ALL inclusive. ALL parameters
have been met.
-Class 5 + Class 6

-No indicator or integrator promises sterility

Immediate Use settings:
What makes it different? - CORRECT ANSWERS-270 10 min + BIO + Class 5
integrator

-Uses a rigid sterilization container with a lid.
-Must do same decontam process.
-Immediate Use has a shorter dry time.
-Items can be WET and it's OK
-NEVER use linens/wraps/packages in Immed Use

What has to be done for ALL steam sterilizers (PreVac/Dynamic, Gravity, IUS) -
CORRECT ANSWERS--Daily QCs with BIOLOGICALS to check for spores.
-Keep a sterilization log.

Document information

Uploaded on
April 5, 2025
Number of pages
61
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$18.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Sold
1
Followers
0
Items
31
Last sold
4 months ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions