What is the setback for a Septic Tank from a proposed or existing Well? - Answer 50 Ft What is the setback for a Septic Tank from a spring, sink hole or suction line (water supply)? - Answer 50 Ft What is the setback for a Septic Tank from a Lake, Pond, Stream, Water course, or other impoundment? - Answer 25 Ft What is the setback for a Septic Tank from pressurized water lines? - Answer 10 Ft What is the setback for a Septic Tank from property lines? - Answer 10 Ft What is the setback for a Septic Tank from a Crawl Space or Foundation? - Answer 10 Ft What is the setback for a Septic Tank from from Drainage Ditches or Embankments? - Answer 15 Ft What is the setback for a Septic Tank from a Swimming Pool? - Answer 10 Ft What is the setback for a Septic Tank from a Driveway or Sidewalk? - Answer 10 Ft What is the setback for a Septic Tank from Tennis Courts or Wooden Deck? - Answer 10 Ft What is the setback for a Absorption Field from a proposed or existing Well? - Answer 100 Ft What is the setback for a Absorption Field from a Spring or Sink Hole? - Answer 100 Ft What is the setback for a Absorption Field from a Lake, Pond, Stream, Water Course or other impoundment? - Answer 50 Ft What is the setback for a Absorption Field from pressurized water lines? - Answer 10 Ft

Content preview

Georgia Commercial Contractor Septic
Exam Study Guide Questions And Actual
Answers.
What is the setback for a Septic Tank from a proposed or existing Well? - Answer 50 Ft



What is the setback for a Septic Tank from a spring, sink hole or suction line (water supply)? -
Answer 50 Ft



What is the setback for a Septic Tank from a Lake, Pond, Stream, Water course, or other
impoundment? - Answer 25 Ft



What is the setback for a Septic Tank from pressurized water lines? - Answer 10 Ft



What is the setback for a Septic Tank from property lines? - Answer 10 Ft



What is the setback for a Septic Tank from a Crawl Space or Foundation? - Answer 10 Ft



What is the setback for a Septic Tank from from Drainage Ditches or Embankments? - Answer
15 Ft



What is the setback for a Septic Tank from a Swimming Pool? - Answer 10 Ft



What is the setback for a Septic Tank from a Driveway or Sidewalk? - Answer 10 Ft



What is the setback for a Septic Tank from Tennis Courts or Wooden Deck? - Answer 10 Ft



What is the setback for a Absorption Field from a proposed or existing Well? - Answer 100 Ft



What is the setback for a Absorption Field from a Spring or Sink Hole? - Answer 100 Ft



What is the setback for a Absorption Field from a Lake, Pond, Stream, Water Course or other

, What is the setback for a Absorption Field from property lines? - Answer 5 Ft



What is the setback for a Absorption Field from a Crawl Space or Slab? - Answer 5 Ft



What is the setback for a Absorption Field from basement? - Answer 10 Ft



What is the setback for a Absorption Field from Drainage ditches or Embankments? - Answer
15 Ft



What is the setback for a Absorption Field from a Swimming Pool? - Answer 15 Ft



What is the setback for a Absorption Field from from a Driveway or Sidewalk? - Answer 5 Ft



What is the setback for a Absorption Field from a Tennis Court or Wooden Deck? - Answer 5 Ft



When is a Commercial Contractors Certification required? - Answer To install any system with
a design flow greater than 2000 gallons per day.



What is the minimum size for a Septic Tank? - Answer 1000 Gallons



If a Garbage Grinder/Garbage Disposal is to be used how much larger must the Septic Tank be
sized? - Answer Tank capacity shall be increased by 50%. Example: A 4 bedroom home would
normally require a 1000 gal tank, if a garbage disposal is installed a 1500 gal tank would be
required.



If Septic Tanks are trained together how much volume must the first tank hold? - Answer At
least 2/3rds of the volume of the 24 hour flow.



The treatment capacity for all septic tanks shall be sized for what volume? - Answer The daily
(24 hour) peak volume of the facility being served.



Inlet and Outlet T's are required to meet what specifications? - Answer 4" , PVC, ASTM 3034
Rated

Document information

Uploaded on
April 5, 2025
Number of pages
6
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$10.79

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
TestSolver9
3.5
(168)
Sold
966
Followers
128
Items
30929
Last sold
11 hours ago


Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions