PROPANE PRACTICE TESTS UPDATED ACTUAL Exam Questions and CORRECT Answers According to the Two Permanent Openings Method one opening must commence within ____ and one must commence within ___ of the enclosure - CORRECT ANSWER of the top 12 inches of the bottom Room heaters shall NOT be installed in what occupancies? - CORRECT ANSWER Health care and Residential board and care. Define a type B-W gas vent: - CORRECT ANSWER - 12 inches - - It shall not have a listed capacity NOT LESS than that of the listed vented wall furnace to which it is connected

Content preview

PROPANE PRACTICE TESTS UPDATED
ACTUAL Exam Questions and CORRECT
Answers
According to the Two Permanent Openings Method one opening must commence within ____
and one must commence within ___ of the enclosure - CORRECT ANSWER - 12 inches
of the top 12 inches of the bottom


Room heaters shall NOT be installed in what occupancies? - CORRECT ANSWER -
Health care and Residential board and care.


Define a type B-W gas vent: - CORRECT ANSWER - It shall not have a listed capacity
NOT LESS than that of the listed vented wall furnace to which it is connected.


Listed vented wall furnaces shall use which type of venting system? - CORRECT
ANSWER - Type B-W gas vent


NO portion of a venting system shall extend or pass through any.... - CORRECT
ANSWER - Fabricated air duct OR Furnace plenum


The exit terminals of mechanical draft systems shall not be LESS than ___________ when
located adjacent to public walkways. - CORRECT ANSWER - 7 ft above finished ground
level


Forced draft systems and all portions of induced draft systems under positive pressure during
operation shall be designed and installed so as to _____________. - CORRECT
ANSWER - Prevent leakage of flue gases into the building



Mechanical draft systems shall be _______ . - CORRECT ANSWER - Listed

,A chimney for residential type or low heat appliances shall extend at least 2 feet higher than any
portion of a building within a horizontal distance of _______. - CORRECT ANSWER - 10
feet


Category I Vented appliance - CORRECT ANSWER - An appliance that operates with a
non-positive vent static pressure and with a vent gas temperature that avoids excessive
condensate production in the vent.


Type 1 and Type 2 clothes dryers shall be exhausted to the ________. - CORRECT
ANSWER - Outside


Ventilating hoods and exhaust systems shall be ________ installed in commercial applications
and to vent industrial equipment. - CORRECT ANSWER - Permitted to vent gas
appliances


What appliances are NOT required to be vented? - CORRECT ANSWER - Counter
appliances or Direct gas-fired make-up air heaters


What is the correct spacing of supports for 3/4" or 1" steel pipe? - CORRECT ANSWER -
Every 8 feet


Regarding indoor combustion air, what method states the minimum volume shall be 50 cube feet
per 1000 Btu/hour? - CORRECT ANSWER - Standard method



All dispensers shall be installed on what type of foundation? - CORRECT ANSWER -
Concrete


The number of containers in a building undergoing minor renovations shall NOT exceed the
________ assigned to using the LP-gas. - CORRECT ANSWER - Number of workers and
shall not exceed ______ lbs in size


Aboveground containers shall be ________. - CORRECT ANSWER - Painted

, All regulators for outdoor installations shall be designed, _______ or protected so that operation
will not be affected by the elements. - CORRECT ANSWER - Installed


Temperature sensitive elements of emergency shutoff valves shall NOT be ________ . -
CORRECT ANSWER - Painted


In a piping system where condensation of vapor can occur, piping shall be _______, or means
shall be provided for re-vaporizing the condensate. - CORRECT ANSWER - sloped back
to the container


What is the minimum cover that should be maintained over all underground metallic piping? -
CORRECT ANSWER - 12 inches


Polyethylene piping systems shall be limited to vapor service not exceeding ________. -
CORRECT ANSWER - 30 psig


A listed __________ shall be installed at the discharge end of the transfer hose at vehicle fuel
dispensers. - CORRECT ANSWER - Quick-acting shutoff valve


Metallic pipe joints shall be permitted to be ____________ using proper pipe and fittings. -
CORRECT ANSWER - Welded or Brazed


Flexible metallic connectors shall NOT exceed _________ in overall length when used with
liquid or vapor piping on stationary containers of 2000 gallon w.c. or less. - CORRECT
ANSWER - 5 feet


Hose length at a motor fuel dispensing station may NOT exceed _____________ unless
approved by AHJ. - CORRECT ANSWER - 18 feet

Document information

Uploaded on
April 3, 2025
Number of pages
23
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$11.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
MGRADES
4.0
(235)
Sold
1537
Followers
108
Items
109649
Last sold
1 hour ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions