. One of the significant causes of leaks in underground liquid storage systems is
1
?____________ ________________
Improper Installation
2. Written Plans are required to?
obtain permits, solicit bids, and provide precise guidance for installers.
3. The plans should?
escribe the property, identify the size and location of the tanks, indicate the
D
liquids to be stored and provide the location of the dispensers and piping.
4. Storage systems discussed in this recommended practice are usually regulated by?
Federal, state or local agencies.
5. All owners should ensure that the equipment to be installed meets?
applicable regulatory requirements before being installed
. Consult the local authorities who have jurisdiction in the area before storage-system
6
plans are.
finalized or construction is initiated.
. All owners should ensure that the equipment to be installed meets all applicable
7
regulatory requirements before?
Being installed.
,8. To avoid damage tanks must not be?
dropped, dragged, or handled with sharp objects.
9. Tanks must not be dropped, dragged, or handled with sharp objects to avoid.
Damage to the tank
10. The only time tanks really should be moved is when?
for inspections and testing.
11. If a tank is damaged at throughout the moving process it must be?
Repaired following the manufacturer's instructions.
12. The proper way to move a tank is by lifting it, using the?
Lift lugs that are installed by the manufacturer.
13. Tanks should be carefully lifted and lowered using?
Cables or chains of adequate length.
4. When two lifting lugs are being used, the angle between the lifting cable and vertical
1
should be no more than?
30 degrees.
5. Stockpile piping materials and equipment in a ____________?_ _________ on the
1
job site
Secure area
16. Confirm adherence to specifications by reporting to the owner about any.
detected damage that could result in leakage or premature corrosion.
, 7. Pressure test single-walled tanks with __?___ to ____?___ psig air pressure,
1
soaping all surfaces, seams and fittings while inspecting for bubbles.
3 to 5
18. Air testing with over _?__ psig (3 Psig for 12-ft. Diameter FRP tanks) is hazardous
nd may damage the tank
a
5 psig
19. Do not air test a tank that has previously contained?
flammable or combustible liquids
20. Place ___?___ barricades at the ends of tanks being tested.
Warning
21. Avoid tank ends, man-ways, and fittings while the tank is under.
Pressure
22. Release pressure in the tank before disconnecting any.
gauges or test fittings.
3. Be aware some manufacturers do not tighten fittings to allow for _____?________
2
______?_______ during shipping and storage.
Temperature changes
4. True or False: Air tests are inconclusive without soaping and careful inspection for
2
bubbles?
True
5. Tank gauges must have a scale that will permit detection of small changes in
2
______?____ that might go undetected on gauges with a __________?_ _________.
Pressure, broader range.