• Wrong document? Swap it for free
  • Written by students who passed
  • Immediately available after payment
  • Read online or as PDF
Sell
Where do you study
Your language
Document preview thumbnail
Preview 2 out of 12 pages
Exam (elaborations)

FLS Modules Questions with Complete Solutions

Document preview thumbnail
Preview 2 out of 12 pages

FLS Modules Questions with Complete Solutions /Laproscopic instruments diameter and length ranges - Answer-2-10mm, 30-45cm /.hopkins rod lens - Answer-light has to travel back through the rod to capture the image. /.decreasing light in the camera for... - Answer-decreasing diameter, increasing scope angle (ie 5mm and 30 degree has less light than 10mm 0 degree) /.When is zero degree scope most useful - Answer-when working in a small area directly in line with the scope and ports, like the pelvis /.how to check fiber optics light connection - Answer-black dots= broken fibers /.why does it fog up? - Answer-temperature and humidity discrepancy between the OR and body /.tools for defogging - Answer-FRED antifog (must dry before putting back in), put laparoscope in hot water /.methods to clean a smudged lens - Answer-gently wipe on clean tissue (liver, uterus, bowel), remove scope and clean with hot water and gauze /.Insufflation gas type and reasoning - Answer-CO2- readily available, inexpensive, non combustable, warmed and humidified better /.high flow insufflation - Answer-10 or more L per minute /.preventing loss of pneumo with suctioning - Answer-keep suction tip below the fluid level /.most common light source - Answer-300W xenon lamp /.Troubleshooting steps: gas preOP - Answer-1. check that co2 tank is full 2. check co2 tank gasket is secured 3. check that spare co2 tank is available in the OR /.troubleshooting steps: image - Answer-1. check that the monitor is plugged in and turned on 2. check that all cables are connected securely /.troubleshooting steps: loss of working space: insufflator settings: measured pressure is the same or higher than the preset pressure - Answer-1. the patient may not be adequately relaxed or there is a mechanical block of gas flow 2. inspect abdomen for rhythmic muscle contraction and palpate the abdomen for firmness 3. check port valves to make sure they are open 4. check for kinks in tubing and make sure no one is standing on them /.troubleshooting steps: loss of working space: insufflator settings: low pressure and high flow rate - Answer-1. there is a leak in the insufflation circuit 2. check that the tubing has not become disconnected from insufflator or port 3. check that all valves are closed 4. check all port sites for leaking co2 5. check for foley catheter bag distention or bowel distention /.troubleshooting steps: loss of working space: insufflator settings: low pressure and no flow - Answer-1. make sure that the insufflator power is on 2. check gas level in the tank /.troubleshooting steps: loss of working space: complete loss of operative image - Answer-1. check for disconnected power cords, video cables 2. check for blown light source bulb 3. check for disconnected light cable /.Monopolar electrosurgery curcuit - Answer-electrical surgical unit--active electrode--patient tissue--dispersive electrode (grounding pad) low frequency from wall source to high frequency at active electrode /.monopolar: tissue coagulation - Answer-occurs as a result of tissue heating and protein denaturation. /.monopolar: desiccation - Answer-tissue temp rises---water is evaporated from the tissue-- increased impedance--- electricity stops flowing because of increased resistance--tissue turns brown, bubbles and steams. Hemostasis due to fibrous binding between dehydrated, denatured cells of vessel endothelium /.monopolar: current density - Answer-amount of current flowing through cross sectional area. directly proportional to power, inversely related to tissue resistance ie larger the area, less current density /.monopolar: cut mode - Answer-heat tissue quickly. cell water is converted to steam, causing the cell to explode. minimal later

Content preview

FLS Modules Questions with Complete Solutions

/Laproscopic instruments diameter and length ranges - Answer-2-10mm, 30-45cm

/.hopkins rod lens - Answer-light has to travel back through the rod to capture the
image.

/.decreasing light in the camera for... - Answer-decreasing diameter, increasing scope
angle (ie 5mm and 30 degree has less light than 10mm 0 degree)

/.When is zero degree scope most useful - Answer-when working in a small area
directly in line with the scope and ports, like the pelvis

/.how to check fiber optics light connection - Answer-black dots= broken fibers

/.why does it fog up? - Answer-temperature and humidity discrepancy between the OR
and body

/.tools for defogging - Answer-FRED antifog (must dry before putting back in), put
laparoscope in hot water

/.methods to clean a smudged lens - Answer-gently wipe on clean tissue (liver, uterus,
bowel), remove scope and clean with hot water and gauze

/.Insufflation gas type and reasoning - Answer-CO2- readily available, inexpensive, non
combustable, warmed and humidified better

/.high flow insufflation - Answer-10 or more L per minute

/.preventing loss of pneumo with suctioning - Answer-keep suction tip below the fluid
level

/.most common light source - Answer-300W xenon lamp

/.Troubleshooting steps: gas preOP - Answer-1. check that co2 tank is full
2. check co2 tank gasket is secured
3. check that spare co2 tank is available in the OR

/.troubleshooting steps: image - Answer-1. check that the monitor is plugged in and
turned on 2. check that all cables are connected securely

/.troubleshooting steps: loss of working space: insufflator settings: measured pressure is
the same or higher than the preset pressure - Answer-1. the patient may not be
adequately relaxed or there is a mechanical block of gas flow

, 2. inspect abdomen for rhythmic muscle contraction and palpate the abdomen for
firmness
3. check port valves to make sure they are open
4. check for kinks in tubing and make sure no one is standing on them

/.troubleshooting steps: loss of working space: insufflator settings: low pressure and
high flow rate - Answer-1. there is a leak in the insufflation circuit
2. check that the tubing has not become disconnected from insufflator or port
3. check that all valves are closed
4. check all port sites for leaking co2
5. check for foley catheter bag distention or bowel distention

/.troubleshooting steps: loss of working space: insufflator settings: low pressure and no
flow - Answer-1. make sure that the insufflator power is on
2. check gas level in the tank

/.troubleshooting steps: loss of working space: complete loss of operative image -
Answer-1. check for disconnected power cords, video cables
2. check for blown light source bulb
3. check for disconnected light cable

/.Monopolar electrosurgery curcuit - Answer-electrical surgical unit-->active electrode--
>patient tissue-->dispersive electrode (grounding pad)

low frequency from wall source to high frequency at active electrode

/.monopolar: tissue coagulation - Answer-occurs as a result of tissue heating and
protein denaturation.

/.monopolar: desiccation - Answer-tissue temp rises--->water is evaporated from the
tissue--> increased impedance---> electricity stops flowing because of increased
resistance-->tissue turns brown, bubbles and steams.

Hemostasis due to fibrous binding between dehydrated, denatured cells of vessel
endothelium

/.monopolar: current density - Answer-amount of current flowing through cross sectional
area.

directly proportional to power, inversely related to tissue resistance

ie larger the area, less current density

/.monopolar: cut mode - Answer-heat tissue quickly. cell water is converted to steam,
causing the cell to explode. minimal later thermal tissue damage, but poor thermal

Document information

Uploaded on
March 28, 2025
Number of pages
12
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$13.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Brainariam
3.4
(30)
Sold
160
Followers
7
Items
8410
Last sold
1 month ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions